Previous Topic: GSVH - General  Health Checker MessagesNext Topic: GSV0 - General Group 0, GSV1 - General Group 1


GSVX - General Group Base

GSVX001E Invalid command - <comname>

The command <comname> is an invalid command and is not a subcommand of the active command. Issue the RECALL command to redisplay the invalid command on the command line. Issue a valid command.

GSVX002E <idn> NSS-PC processing failed - R15 <reg15> R0 <reg0> R1 <reg1>

A command module has called the PC of this product, and the PC has terminated due to an abnormal condition. The <idn> variable is an identifier that can be JCSR, ROSR, or XMDS. <reg15, reg0>, and <reg1> are the values in Registers 15, 0, and 1, respectively. If <reg15> is greater than 001C, issue the STATUS command and print the contents of the entire display (PRINT ALL). Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX003E LOAD failed for module <modname>

The attempt to load module <modname> has failed. If <modname> is a SYSVIEW module, check to make sure the SYSVIEW modules are in a linklist library. Also, check the console log for the reason the load failed.

GSVX004E GETMAIN for workarea failed. Routine <rtn> <offs> <lng>

The request for storage for a workarea failed. The session terminates. Increase the region size of the application where SYSVIEW is running. The routine name <rtn>, offset <offs>, and length of storage requested are also displayed in the message.

GSVX005I Beginning of <data/info> <rows/columns>

The display is at the beginning of the data or info rows or columns.

GSVX006I End of <data/info> <rows/columns>

The display is at the end of the data or info rows or columns.

GSVX007E Error while processing input data - RC= <code>

An error has occurred during processing of the input data typed by the user. <code> is the return code. If this message is received while running the batch interface, check to make sure the first input control card is a DATA control card that defines the user ID. If this message is received repeatedly, note the return code and the circumstances in which the error occurred. Contact CA Technical Support.

RC and description:
GSVX008E Invalid scroll command parameter - <scrollamt>

The scroll command parameter <scrollamt> contains an invalid number of lines or columns to scroll. Make sure the number is a decimal number. Also, make sure any input data left on the command line is cleared before a scrolling PF key is used.

GSVX009E Maximum levels exceeded - command ignored

The command has attempted to create another level, but that attempt exceeds the maximum number of nested levels. Return to the previous level before issuing the command to create another level.

GSVX010E Delimiter error on parameter <parmnumb>

The parameter <parmnumb> specified with the command did not specify the ending character delimiter. Issue the RECALL command to redisplay the command on the command line. Specify the ending character delimiter on the <parmnumb> in error, and issue the command again.

GSVX011E Length error on parameter <parmnumb>

The parameter <parmnumb> specified with the command exceeds the maximum parameter length. Check the command documentation for the maximum parameter length. Issue the RECALL command to redisplay the command on the command line. Issue the command again with a valid length for the <parmnumb> in error.

GSVX012E Number of parameters specified exceeds maximum allowed

More parameters are specified with the command than the command supports. Check the command documentation for the correct parameter format. Issue the RECALL command to redisplay the command on the command line. Issue the command again with the correct number of parameters.

GSVX013E At least one parameter must be specified with the <command>

The command has been entered without a parameter; the command requires at least one parameter. Check the command documentation for the correct parameter format. Issue the RECALL command to redisplay the command on the command line. Issue the command again with at least one parameter.

GSVX014I <userid> entered <command comparms>

User <userid> has issued a command and the command has the message action set. The message shows the user ID <userid>, the command <command>, and the command parameters <comparms>. For details on setting the message action for a command, see the Security Guide.

GSVX015I <userid> entered the <comname> command for job <jobname>

The user <userid> has issued a command for a job with the message action set. The message shows the user ID <userid>, the command name <comname>, and the job <jobname>. For details on setting the message action for a job, see the Security Guide.

GSVX016I Command issued - <operator_command>

The MVS command has been used to issue the operator command. The message displays the user-issued command <operator_command>.

GSVX017I The PF key entered is not defined

The PF key pressed is not defined in the profile for the active command. Issue the PROFILE or SET command to define a value for the PF key.

GSVX018E Main anchor block locate or create failed

The SYSVIEW main common anchor block could not be located or created.

GSVX019I JES2 is not active

The command entered requires information from JES2, but JES2 is not active. Issue the command again when JES2 is active.

GSVX020I <command> is disabled

The command is disabled.

GSVX021E <Password|Passphrase> not matched and retry limit reached. Session terminated.

An attempt to logon failed because the correct password or passphrase was not entered and the retry limit was reached.

GSVX022E Highlighted input fields are invalid

The highlighted input fields contain invalid data. Check the command documentation for correct values for the highlighted input fields.

GSVX023E Global load for module <modulename> failed, abend <abndcd>

The global load for the specified module failed with the specified abend code.

GSVX024E Allocation failed for volume <volname> - rc <code>

The attempt to dynamically allocate the JES2 spool volume <volname> has failed. <code> is the return code. For a definition of the return code, see the SVC 99 Return Codes section in the IBM documentation.

GSVX025E DEVTYPE failed for volume <volname>

The DEVTYPE macro has failed for JES2 spool volume <volname>. Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX026E OPEN failed for volume <volname>

The attempt to open the JES2 spool data set has failed. The message shows the volume name <volname> of the spool volume that could not be opened. Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX027A Confirm all highlighted line commands by entering YES

When delete confirmation is in effect, the command is ready for confirmation. Enter YES on the command line to confirm all highlighted line commands. Clear the line command to cancel the request.

GSVX028E Invalid parameter specified with <comname> command

The command <comname> has an invalid parameter. Issue the command again, using a valid parameter.

GSVX029E Invalid release for module <modname>

An invalid release of the SYSVIEW module <modname> has been loaded. Make sure the correct SYSVIEW modules are in the linklist or STEPLIB library. If you are using a STEPLIB library, make sure all of the STEPLIB libraries are APF authorized.

GSVX030E GETMAIN during initialization failed

The request for storage during initialization failed because there is not enough available storage. The session terminates. Increase the region size of the application where SYSVIEW is running.

GSVX031E LOAD failed for module <modname>, <reason>

The attempt to load a module named <modname> failed. The reason for the load failure is <reason>. Check to make sure the module <modname> is in an accessible library. Also, check the console log for any additional load failure messages.

GSVX032E PARMLIB member name not supplied

The SYSVIEW address space requires a startup PARMLIB member name to be supplied. Make sure a member is specified by the MEM= parameter in the SYSVIEW procedure and that the member exists in the SYSVIEW PARMLIB data set.

GSVX033E Invalid member name <member>

An invalid member name or data set (member) has been specified.

GSVX034E GETMAIN for workarea failed. Command cannot get the requested data

A command module tried to obtain storage for a work area, but there was not enough storage available. Increase the region size.

GSVX035E Invalid password entered for <userid>

User <userid> has specified an incorrect password when attempting to use SYSVIEW. The session terminates. Verify your password with your SYSVIEW Security Administrator.

GSVX036I <userid> was denied the <comname> command for job <jobname>

The user <userid> has attempted to use a command with a jobname for which she or he is not authorized, and the message action is set for a jobname. The message shows the user <userid>, the command <command>, and the job <jobname>. For details on setting the message action for a job, see the Security Guide.

GSVX037I User <userid> not authorized for SYSVIEW through this interface

The user <userid> is not authorized to use SYSVIEW.

GSVX038I Data not saved

Output viewed with ISPF edit cannot be saved.

GSVX039E <cmdname> command requires <feat> feature

The command <cmdname> requires the feature <feat> that either was not requested or was not authorized. Features refer to options and components selected in the system configuration parmlib member parameters:

See the Installation Guide for more information.

GSVX040I <userid command restype resvalue>

The user <userid> has issued the command <command> for resource type <restype> with resource value <resvalue>. The message action is set for this resource. For details on setting the message action for a resource, see the Security Guide.

GSVX041E Not authorized for command <comname>

The user is not authorized to issue the MVS command <comname>. If you must use the command, contact your Security Administrator for permission.

GSVX042E Invalid copy dataset name in profile

The attempt to access the copy data set failed because the data set name specified in the profile is invalid. Check the GENERAL section of the profile for the copy data set name.

GSVX043I <userid> issued command <comname>

User <userid> has issued the MVS command <comname> with the message action set. For details on setting the message action for an MVS command, see the Security Guide.

GSVX044I <user> entered <cmd> command for job <jobname> <num>, DD <ddname>

The user <user> has issued a command for an output file that has the message action set. The message shows the user ID <userid>, the command type <cmd>, the jobname <jobname>, the job number <num>, and the ddname <ddname> of the output file. For details on setting the message action for an output file, see the Security Guide.

GSVX045I Waiting for timer exit post, TCB <tcba> ID <id> ECB <ecba> <ecb>

This message is logged when an "STIMERM CANCEL" was issued to cancel a timer interval and it was found that the timer interval was not queued meaning that the timer exit had run or will run. This message identifies the TCB address, the timer identifier, the ECB address, and the ECB contents for which a WAIT will be issued.

GSVX046E STIMERM failed - RC=<code>

The attempt to establish a timer has failed for the LOG or JOBS task. The task terminates. <code> is the return code.

GSVX047E GETMAIN failed - RC=<code>

The attempt of the LOG task to get storage has failed. The LOG task terminates. It is possible that there is not enough storage available in the SYSVIEW address space. <code> is the return code. Try increasing the region size for the SYSVIEW address space. If you require assistance, note the return code and contact CA Technical Support.

GSVX048I Source string: <string>

This message is logged following the message:

GSVX553W Truncation occurred during variable substitution

to display the source string that was being processed when the variable scan-and-replace encountered a truncation problem.

GSVX049E Unable to perform cancel action. Job status has changed

The cancel line command has been entered for a job on the Activity Display after the job has executed. Clear the line command, or enter the REFRESH subcommand to continue. Informational only.

GSVX050W RMF monitor III is not active

In order to get information for some of the displays, RMF monitor III must be active. Start RMF monitor III and try the command again.

GSVX051W A timeout occurred when gathering RMF data

A request for data from RMF timed out. Retry the command again. If this message is received repeatedly, contact CA Technical Support.

GSVX052E Invalid command for SYSVIEW address space - <comname>

Either the MODIFY command or the initialization parameter <comname> entered for the SYSVIEW address space is invalid. For valid MODIFY commands and valid initialization parameters, see the Administrator Guide.

GSVX053E Invalid keyword <keyword> specified

An invalid keyword has been entered. Review the command syntax.

GSVX054E Invalid value for <keyword> keyword

A keyword was entered that requires a value. A value that was supplied is not valid.

GSVX055E Log stream <logstream> is not logname type <type>

The log stream specified does not contain the correct type of data or has not been defined in the LGLOOKUP parmlib member.

GSVX056E 56E Allocation failed, invalid <parmname> parameter

Data set dynamic allocation has failed because of an invalid <parmname> parameter value.

GSVX057I <function> has been <action>

This message indicates that a function has been initialized, terminated, or the action specified.

GSVX058E Invalid <modnm> module release, found <rel bld>, need <rel bld>

The release validation process failed for the module named <modname>. The release and build that were found and the release and build required are displayed if available. When this message occurs very early in the initialization process the format will be:

Invalid release for module <modname>

GSVX059I <ddn> ddname caused bypass of "XINSR INSTALL" call

The ddname <ddn> was found to be allocated and this caused the call to "XINSR INSTALL" to be bypassed.

GSVX061E NSS-PC module <modnm> not at build <bld> or higher

The NSS-PC module named <modname> is not at build <bld> or higher. This can occur when multiple releases of CA SYSVIEW are in use on the same system and the NSS-PC modules are at the older release. The modules of the new release have not been installed because the SYSVIEW server address space has not yet been started to install the newer modules

GSVX062E Panel <panname> is invalid

The panel <panname> contains no displayable lines. The panel library is specified in the system configuration parmlib member parameter:

Dsn-System-PANELLIB <paneldsn>

Make sure <panname> is not corrupted.

GSVX063E <seckwd> keyword invalid for <cmd prikwd> <type>

The secondary keyword <seckwd> is invalid for the <type> and primary keyword <cmd prikwd>. An example of this message is <BIG keyword invalid for SET SCREENSIZE command>.

GSVX064E Locate command table entry failed, <var1> name <var2> not found

The <var1> variable will be either command or module. The <var2> variable is the name of the command or module which was not found in the command table. If you receive this message, note the circumstances in which it occurred and contact CA Technical Support.

GSVX065E Device lookup failed, RC=<code>

The MVS device lookup service has failed, with return code <code>. For more information, see the appropriate IBM documentation. Contact CA Technical Support.

GSVX066E Only 1 parameter allowed on <name> <type>

The <name> <type> was issued with more than 1 parameter.

GSVX067E Only <x> parameters are allowed on the <name> <type>

The <name> <type> was issued with more parameters than are allowed.

GSVX068E Closing delimiter not found on <parm> <type> parameter

The issued <type> requires a closing delimiter on the parameter <parm>. Issue the <type> again, specifying a closing delimiter.

GSVX069E <parm> <type> parameter <???> is too long, the max length is <xxx>

The parameter <parm> is too long. <xxx> is the maximum length of the parameter. Issue the <type> again, specifying a parameter of valid length.

GSVX070E No parameters allowed on the <name> <type>

The <name> <type> has been issued with parameters. The <type> does not have any parameters. Issue the <type> again, without specifying any parameters.

GSVX071E <kwd> is not a valid keyword for the <cmd> <type>

The keyword <kwd> specified with the <cmd> <type> is not valid for the <type>. Issue the <type> again, specifying a valid keyword.

GSVX072I ASID <asid> inactive

The ASID <asid> is inactive.

GSVX073I Job <jobname> ended - ASID <asid> inactive

The ASID <asid> specified by job <jobname> is inactive.

GSVX074I Job <job1name> ended - Job <job2name> now active

The job <job1name> has ended and job <job2name> is now running.

GSVX075E NSS-PC timed out in ASID <asid>, job <jobname> - ASID reset to HOME

The SYSVIEW NSS-PC cannot gather information from the desired address space in the allotted time. This situation usually indicates a major MVS problem with the address space. The target address space, therefore, is internally switched back to the HOME ASID to avoid any more interaction with the address space. You can retry the command, but we recommend that first you use the ACTIVITY and CONSOLE commands to check the overall status of the system.

GSVX076E NSS-PC failed, ASID <asid> not active

The NSS-PC has failed because the address space <asid> is not active.

GSVX077E NSS-PC failed, timeout in ASID <asid>

The issued command requires information from another address space. The resulting NSS-PC to gather that information has failed because the target address space did not respond within 15 seconds. This situation usually occurs when the target address space is swapped out and the MVS SRM (system resource manager) cannot or will not swap it back in.

GSVX078E Error occurred scanning VSM control blocks, <data> data is incomplete

An error has occurred during scanning for the data <data> in the VSM control blocks. Contact CA Technical Support.

GSVX079E Invalid scroll amount

The scroll amount field (Scroll ===>) has been modified with an invalid value. Specify a valid scroll amount. Valid values are the same as the parameters of the scroll commands.

GSVX080W <ddname> ddname forced "<condname>" condition

The ddname <ddname> was found to be allocated and this forced a <condname> condition. This is just for testing.

GSVX081I Job <jobname> now active in initiator

The current ASID was initially selected by ASID, and the active jobname was an initiator. Since then, the job <jobname> has started executing in the initiator.

GSVX082I Job <jobname> ended, initiator inactive

The batch job <jobname> that had been active in the selected address space has ended. The initiator is now inactive.

GSVX083W Insufficient storage, <nnn> lines lost

There was not enough storage available to display all of the information for the command. <nnn> is the number of lines not displayed.

GSVX084E Control block error, <nnn> lines lost

An error has occurred during MVS control block processing, and some information is unavailable.

GSVX085E <cmd> command failed, control block error <errinfo>

The <cmd> command failed while processing MVS control blocks. The <errinfo> field contains additional information about the error. Contact CA Technical Support.

GSVX086E Allocate <dsname> failed, <xxxxxxxx>

Dynamic allocation of the data set <dsname> has failed. The IBM error codes <xxxxxxxx> are supplied. For an explanation of the error codes, see the IBM documentation in MVS Authorized Assembler Services Guide.

GSVX087E <dsname> not cataloged

Dynamic allocation of the data set <dsname> has failed because the data set is not cataloged. Catalog the data set.

GSVX088E <dsname> not found on volume

Dynamic allocation of the data set <dsname> has failed because the data set cannot be found on the volume specified in the catalog.

GSVX089E Volume not mounted for <dsname>

Dynamic allocation of the data set <dsname> has failed because the data set resides on a volume that is not mounted.

GSVX090E Dataset in use - <dsname>

Dynamic allocation of the data set <dsname> has failed because some other job has exclusive control of the data set.

GSVX091E Invalid dataset name - <dsname>

Dynamic allocation of the data set <dsname> has failed because it is not a valid data set name. Try the allocation again, using a valid data set name.

GSVX092E <parmname> parameter required by <comname> command

The <comname> command requires the <parmname> parameter. Issue the command again, specifying the required parameter.

GSVX093I No match found for specified parameters

No match is found for the parameters specified either with the command or on the parameter line.

GSVX094E Keyword <keyname> is ambiguous - Specify more chars for exact match

The keyword <keyname> is not long enough to be unique. The command supports more than one keyword parameter. Issue the command again, using a unique keyword. For example, for the valid keywords TAPE and TP, T would be ambiguous but TA would not.

GSVX095W <ddname> ddname forced "SGAT block not found" condition

The ddname <ddname> was found to be allocated and this forced an "SGAT block not found" condition. This is just for testing.

GSVX096E <servname> request failed, <codes>

An SVC 99 request has failed for <servname>, which can be one of the following:

<codes> is the error codes. For an explanation of the error codes, see the IBM documentation in MVS Authorized Assembler Services Guide.

GSVX097I SYSVIEW session timed out

The session of a user has timed out. For details on setting timeout values for secrutiy groups, see the Security Guide.

GSVX098E <cmdname> invalid, required XXMDS-PC services unavailable

The <cmdname> command is invalid because the SYSVIEW XXMDS nonspace switch PC services are not available.

GSVX099I SYSVIEW logon terminated

Logon processing has terminated because a PF key was pressed while the user ID and password prompt screen was displayed.

GSVX100E SYSVIEW primary address space already active

The attempt to start the SYSVIEW address space with the PRIMARY keyword in the initialization parameters has failed because a primary SYSVIEW address space is already active. If another SYSVIEW address space must be started, remove the PRIMARY keyword from the initialization parameters.

GSVX101I JCL or SYSIN files are not available

An attempt to display the JCL for a job failed because all of the necessary files were not available. A job must be submitted on the current system in order to display the JCL for the job. Also the job must not be a transaction job.

GSVX102I Authorization check: APF=@<3> SUPERVISOR=@<3> KEY=@<3>

Informational only.

GSVX103I @<8> Auth check: APF=@<3> SUP=@<3> KEY=@<3> COM8SUPV=@<3> COMMMSCT=#<3>

Informational only.

GSVX104E Terminal not supported

The terminal you are using to sign on to SYSVIEW is not supported by SYSVIEW. SYSVIEW supports 3270-type terminals only. Use another terminal to sign on to SYSVIEW.

GSVX105E <interface> interface already active

The attempt to start the interface <interface> has failed because the interface is already active.

GSVX106E Establishment of recovery environment failed

The attempt to set up a recovery routine has failed. Try starting the session again. If the message is received repeatedly, contact CA Technical Support.

GSVX107E CICS logger type <type> cannot be set to <option>

The attempt has been made to change the current logging options options for a CICS logger task. The current state or configured options will not allow the new request.

GSVX108E Invalid initialization parameter - <xxxxxxxxxxxxxxxxxxx>

The initialization parameter <xxxxxxxxxxxxxxxxxxx> is invalid for the SYSVIEW application. Verify that the initialization parameters of the application are correct.

GSVX109E Invalid option - <erropt>

Informational only.

GSVX110I SYSVIEW interface initialized for <name>

Interface <name> has initialized and is ready to be used.

GSVX111I No users active for status display

The Status Display has been requested, but there are no active users to display.

GSVX112I End of display

A status or trace display has ended.

GSVX113I Maximum users reached for <xxxx> interface

The maximum number of users allowed for interface <xxxx> has been reached. A new user has tried to use the interface and the request is denied. Increase the MAXUSERS initialization parameter for the interface.

GSVX114E Userid processing error

Informational only.

GSVX115E User <user> not accepted - RC=<code>

User <user> tried to sign on to SYSVIEW through an interface, but could not be accepted. <code> is the return code. Note the return code. Contact CA Technical Support.

GSVX116E Data could not be received - RC=<code>

The input data cannot be received. <code> is the return code. Note the return code. Contact CA Technical Support.

GSVX117E New user processing failed - RC=<code>

The necessary resources to establish a new user for the interface are not available. <code> is the return code. If this message is received repeatedly, note the return code. Contact CA Technical Support.

GSVX118E Screen could not be sent - RC=<code>

This error occurs when a screen cannot be sent to the user. <code> is the return code. If you receive this message repeatedly, note the return code. Contact CA Technical Support.

GSVX119E Session termination for <userid> failed, RC=<code>

User <userid> is the target of either of the following:

<code> is the return code. Note the return code. Contact CA Technical Support.

GSVX120I <name> interface shutdown pending

Interface <name> is performing shutdown processing. No logons are allowed.

GSVX121I Print file must be closed before copying output

The attempt to copy output to the copy data set has failed because a print file is opened to the copy data set. Issue the PRINT CLOSE or SNAP CLOSE command, and try to copy again.

GSVX122E No storage available for display data

There is not enough storage to hold the data for a status or trace display. Try increasing the region size of the application where SYSVIEW is running.

GSVX123I Cancel accepted for userid <userid>

The attempt to cancel user <userid> has been accepted.

GSVX124I Cancel not valid for userid <userid>

The attempted cancel of user ID <userid> is invalid because the user ID is either not specified or not active. Issue the command again using a valid user ID.

GSVX125I <interface> interface shutdown requested by <userid>

User <userid> has requested to shut down interface <interface>.

GSVX126I <interface> interface shutdown requested by <userid> delayed - active users

User <userid> has requested that interface <interface> be shut down, but users are still on the interface. The interface will shut down as soon as the active users have terminated their sessions. If you want to force an immediate shutdown, enter the STOP command. Informational only.

GSVX127I No SYSLOGs on the spool. LOG task is terminating

The LOG task has found that there are no SYSLOG output data sets on the JES2 spool.

GSVX128E Invalid trace parameter <parm>

The parameter <parm> is invalid for the TRACE command.

GSVX129E Trace is already active

An attempt was made to start a trace, but the trace is already active. If you want to start a different trace, stop the current trace before starting another one.

GSVX130E Trace was not active

The request to turn off a trace has failed because the trace is not active.

GSVX131I Trace activated

A trace has been activated.

GSVX132I Trace deactivated

A trace has been stopped.

GSVX133I Trace table is empty

The request to list the trace data has found no data to display.

GSVX134E Invalid <modname> modid area, <errdata>

A valid module identification area could not be found in the <modname> module. The module release and build validation process failed. When this message occurs very early in the initialization process the format will be:

Invalid ident for module <modname>
GSVX135E SYSVIEW <xxxx> interface abended

An abend has occurred in the SYSVIEW interface <xxxx>. A dump has been taken. Obtain the dump output. Contact CA Technical Support. Restart the interface.

GSVX136E <comname> command invalid from this application

The command <comname> either does not apply to or is not available from the application where it is specified.

GSVX137E <comname> command invalid, not executing under VM

Informational only.

GSVX138E Errors must be corrected before continuing

An attempt was made to exit a display before correcting the errors. Correct the highlighted lines or use the CANCEL command to cancel the changes.

GSVX139E <idn> NSS-PC processing failed - GETMAIN for <xxx> failed

An attempt was made to acquire CSA or SQA storage, but there was not enough contiguous storage available to satisfy the request. Use the COMMON command to determine if common area storage is fragmented or exhausted. The <idn> variable is a NSS-PC identifier that can be JCSR, ROSR, or XMDS.

GSVX140E <cmdnam> is not a valid external command

Informational only.

GSVX141E No valid <cmdname> request found in PARMLIB member <member>

Command <cmdname> could not be invoked because no valid request was found in member <member>.

GSVX142I <xxxxxxxx> task interval set to <num> seconds

The update time interval <xxxxxxxx> has been changed to <num> seconds for the JOBS or LOG task in the SYSVIEW address space.

GSVX143I Job <jobname jobnum> not found

The job with the name and number of <jobname jobnum> specified cannot be found.

GSVX144I All files have been requeued or deleted

All of the output files for the selected job have been requeued or deleted. If this message is received on the Listjobs Display, issue the REFRESH subcommand and try the L line command again. If this message is received on the Listfile Display, issue another command to continue.

GSVX145I Multiple jobs present. <pos> job number selected for <jobname>

There are multiple jobs in the system with the name <jobname>. The job with the <pos> job number has been selected. <pos> can be Highest, Lowest, Newest, Oldest, or Executing. For details, see the MULTJobs variable of the SET command.

GSVX146I No authorized datasets to display

There are no authorized data sets for the selected job.

GSVX147I No authorized jobs to display

There were jobs that matched the parameters entered, but none were authorized. This message is informational.

GSVX148I <option> option set <value>

Informational only.

GSVX149I List is incomplete

Not enough storage was available to display all of the data. If possible, specify parameters that reduce the amount of data to display.

GSVX150E Invalid line command

The line command specified is invalid. Try again with a valid line command. For a list of valid line commands, see the online help system.

GSVX151E Line command invalid on specified line

The line command specified is not valid on the line from which it was issued. To see the information and restrictions about line commands, use the online help system.

GSVX152I <mbr> not found

A WHERE subcommand was issued to search for a specific or generic member name and no match was found in any of the allocated libraries.

GSVX153W Response buffer overflow -- <nnn> bytes of command responses lost

The response to the VM command is longer than can fit in a single 4 KB buffer (a VM restriction). The number of bytes of responses <nnnnn> is discarded.

GSVX154E Field contains embedded blanks

The highlighted field in the body of the display is invalid. It contains embedded blanks where none are allowed. Remove the embedded blanks and issue the command again.

GSVX155E Field not numeric

The highlighted field in the body of the display is invalid. It contains nonnumeric data where numeric data is required. Remove the nonnumeric data and issue the command again.

GSVX156E Invalid line command - <linecmd>

The line command <linecmd> is not a valid line command from the current screen display. Try again with a valid line command. For a list of valid line commands, see the online help system.

GSVX157E Line command <linecmd> ambiguous, enter more chars for exact match

Line command <linecmd> is not long enough to be unique. Enter enough characters to uniquely identify the line command.

GSVX158E Invalid subcommand - <subcommand>

The subcommand <subcommand> is invalid from the current active command display. Try again with a valid subcommand. For a list of valid subcommands, see the online help system.

GSVX159E Subcommand <subcommand> is ambiguous, enter more chars for exact match

Subcommand <subcommand> is not long enough to be unique. Enter enough characters to uniquely identify the subcommand.

GSVX160A Enter YES to confirm: <xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx>

The issued subcommand or line command requires confirmation, and the setting of the DELETE CONFIRMATION option is YES. Enter YES to continue execution of the indicated function. Enter ALL to continue execution of all the indicated functions. Enter anything else to abort execution of the indicated function.

GSVX161I Request aborted: <xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx>

This message appears if the response to message GSVX160A was not YES.

GSVX162W YES ignored, no pending confirmation

YES was entered when no confirmation was pending. Issue the command that requires confirmation again and then enter YES.

GSVX163E No libraries available to search

A WHERE subcommand was issued to search for a member but there are no libraries available to search.

GSVX164E JES2 version <ver1> not supported. Version <ver2> or higher reqd

The version of JES2 installed <ver1> is no longer supported. The minimum level of JES2 supported is <ver2>. Informational only.

GSVX165I XMSGR SET_EXTERNAL_SEND <action>

Informational only.

GSVX166E <cmd> unavail at <name> <lvl-found>, <lvl-req> reqd

The command <cmd> is not valid in the installed level <lvl-found> of the software component <name>. The required level of the software component is <lvl-req>. Possible values for <name> are MVS, DFP, TSO/E, ISPF, QUICKREF, and VTAM.

GSVX167E Label or line number required for LOCATE command

The LOCATE command was issued without a label name or line number parameter. Issue the LOCATE command again specifying either a label name or a line number.

GSVX168E Label <label-name> not found

The label <label-name> supplied with the LOCATE command was not found in the table of labels defined for the current command. Issue the command again using a valid label. Execute the LABEL command without a parameter to display the current contents of the label table.

GSVX169I <command-name> label <label-name> located

The label <label-name> was found for the current command <command-name> and the line was located. This message confirms that the requested action occurred.

GSVX170I <comname> label <labelname> line <linenum> outside current range

The line number <line-number> defined for the label <label-name> is greater than the currently defined number of data lines. Issue the command again using a valid label. Execute the LABEL command without a parameter to display the current contents of the label table.

GSVX171E <service-routine-name> failed, abend <code>

The service routine <service-routine-name> failed with abend code <code>. Contact CA Technical Support.

GSVX172E <cmdname> command invalid, ISPF services are not available

Command <cmdname> requires the services of ISPF. Access ISPF and issue the command again.

GSVX173E <cmdname> command invalid from <intfc> interface

Command <cmdname> cannot be executed from the <intfc> interface. Check the online help system for a list of valid interfaces.

GSVX174E <cmdname> command unavailable - Load failed for module <modname>

Command <cmdname> cannot be executed because the load for required module <modname> failed. Determine why the load failed and issue the command again.

GSVX175I <appldesc> requested <text>

The <appldesc> application requested special <text> execution attributes. The values for <text> can be the following.

GSVX176E Abend <code> occurred processing <cmdname> command

Command <cmdname> abended with the code <code>. Determine why the abend occurred and issue the command again.

GSVX177E Subsystem call failed - RC=<code>

A subsystem call failed with a return code of <code>. The first two bytes are the subsystem function. The last three bytes are the return code from register 15. Note the return code. Contact CA Technical Support.

GSVX178E Unable to process action. RC=<code> RS=<reason>

The action to be taken for a job cannot be processed. <code> is the return code. Note the return code and the circumstances in which the error occurred. Contact CA Technical Support.

GSVX179E <pgmname> not APF authorized

The program name <pgmname> must be APF authorized. This usually indicates an error in the product installation. Review the installation process and retry the failing job if any mistake was found and corrected. Contact CA Technical Support.

GSVX180E Keyword value required by <cmd> <kwd> <type>

This general purpose error message indicates that the command <cmd> was issued with the keyword <kwd> but the required value for the keyword was not supplied. For information on the command in question, see the online help system.

GSVX181I CpuTime <cputm> ActTime <acttm> IoCount <iocnt>

Informational only.

GSVX182I Initiator started in ASID <asid>

An ASID selected with the ASID command had become inactive and is now active again because an initiator has started.

GSVX183I Initiator started in ASID <asid>, job <jobname> now active

An ASID selected with the ASID command had become inactive and is now active again because an initiator has started and is processing a batch job.

GSVX184I Job <jobname> started in ASID <asid>

A change was detected in jobnames in an ASID selected by the ASID command.

GSVX185I Job in transition in ASID <asid>

A job executing in ASID <asid> is in transition--starting, ending, or abending.

GSVX186E DSID <dspname> no longer valid for job <jobname> ASID <asid>

AR mode is on for a data space that is no longer active. Use the AR command to set AR mode to OFF, the DSID command to switch to another data space, or the ASID command to switch to another address space.

GSVX187E <srvcname> failed - rc <rtncd> rs <rsncd> ec <errcd1 errcd2>

Service <srvcname> failed with the indicated return codes. Contact CA Technical Support.

GSVX188W Insufficient storage to return all data for <srvcname> service

There was not enough storage to return all data for service <srvcname>. Contact CA Technical Support.

GSVX189E <cmdname> is not a valid target command for the LINK command

A link to the <cmdname> command was issued. This is not allowed.

GSVX190E <errkwd> is not a valid <cmd> <type> <kwd> keyword

This is a general purpose error message indicating that an invalid keyword was supplied. Review the documentation for the <cmd> <type> and the options allowed for the <kwd> keyword.

GSVX191E <val> keyword value required by <cmd> <kwd> <type>

This is a general purpose error message indicating that a required keyword was omitted. Review the documentation for the <cmd> <type> and the options allowed for the <kwd> keyword.

GSVX192E <srvcname> failed - rc <rtncd> rs <rsncd>

Service <srvcname> failed with the indicated return codes. Contact CA Technical Support.

GSVX193E Value required for <kwdname> keyword

This is a general purpose error message indicating that a value is required for the <kwdname> keyword. For information on the command that was entered, see the online help system.

GSVX194E Invalid <kwdname> keyword value: <errval>

This is a general purpose error message indicating that an invalid value was specified for the <kwdname> keyword. For information on the command that was entered, see the online help system.

GSVX195E Closing delimiter not found on <parmname> parameter

This is a general purpose error message indicating that a parameter started with the character-delimiter character but no closing character-delimiter character was found.

GSVX196E String qualifier <strqual> not supported for <parmname> parameter

An unsupported character-string qualifier was used on the <parmname> parameter.

GSVX197A Enter <cmd> command to terminate - Enter anything else to continue

The END or RETURN command was issued to terminate the session and the CONFIRMTERM option was set to YES. In response to the message prompts, reenter the END or RETURN command to confirm your intention to terminate your session, or enter anything else to cancel the termination command.

GSVX198I <userid> denied command <mvscmd>

User <userid> attempted to issue the MVS command <mvscmd> but was denied by a security rule. That rule had the message action set. For details on setting the message action for an MVS command, see the Security Guide.

GSVX199I Request completed

The request has been successfully completed.

GSVX200I Attribute <attribute> has been set for command <command>

The specified attribute has been set for the command.

GSVX201E Attempt to set attribute for command <command> failed. Invalid command.

An attempt was made to set an attribute for a command. An invalid command name was specified.

GSVX202E Attribute <attribute> is invalid for command <command>

An attempt was made to set an attribute for a command. The specified attribute is invalid.

GSVX203W System capture data set name hlqual len gt max (28)

The resolved length of the capture data set name high-level qualifier is longer than the maximum length allowed of 28. The capture data set name high-level qualifier will be used but the time and date qualifier (.Thhmmss.Dyymmdd) added to the end of the name will be truncated.

GSVX204I <capdsnhlq>

This message displays the capture data set name high-level qualifier.

GSVX205E Nucleus load failed

Nucleus load processing failed to complete. The SYSVIEW session terminates. This message should be preceded by one or more messages that describe the reason for the failure.

GSVX206E Nucleus initialization failed

Nucleus initialization processing failed to complete. The SYSVIEW session terminates. This message should be preceded by one or more messages that describe the reason for the failure.

GSVX250I <tranid> transaction complete

The SYSVIEW transaction tranid has completed normally under CICS.

GSVX251I User subtask has terminated due to timeout or error

The task that handles the user's data has terminated in the SYSVIEW address space. This could be due to user inactivity and a timeout occurred or the subtask abended. If a timeout did not occur, note the circumstances. Contact CA Technical Support.

GSVX252E SYSVIEW subtask could not be attached - RC= <code>

The attempt to attach the SYSVIEW subtask under CICS has failed. <code> is the return code. Try entering the SYSVIEW transaction again. If this message is received repeatedly, note the return code. Contact CA Technical Support.

GSVX253E Internal error. Control block missing

The control block used for communicating with its CICS subtask cannot be found. Try entering the SYSVIEW transaction again. If you repeatedly receive this message, Contact CA Technical Support.

GSVX254E SYSVIEW subtask has terminated

The subtask under CICS has terminated, possibly because the timeout value has expired for the session. Try entering the SYSVIEW transaction again to start another session. If this message is received repeatedly, Contact CA Technical Support.

GSVX255E CICS interface is not active

The CICS interface must be started in SYSVIEW address space before using the SYSVIEW transaction. For information on how to start the CICS interface, see the Administrator Guide.

GSVX256I CICS interface is shutting down

The CICS interface is in the process of shutting down. The SYSVIEW transaction cannot be used until it is restarted. For information on how to start the CICS interface, see the Administrator Guide.

GSVX257I Post for ECB failed, RC=<rc>

An attempt was made to communicate with the SYSVIEW address space, but the attempt failed. If this message is received repeatedly, note the return code. Contact CA Technical Support.

GSVX258E Load for <module> failed

An attempt was made to load a SYSVIEW module, but the load failed. Check the SYSLOG for the reason why the load failed.

GSVX259I Call to <module> failed, RC=<rc>

An attempt was made to call a SYSVIEW module but the call failed. If this message is received repeatedly, note the return code. Contact CA Technical Support.

GSVX260E Error processing data. Transaction ended RC=<rcrs>

An attempt was made to communicate with the SYSVIEW address space, but the attempt failed. If this message is received repeatedly, note the return code. Contact CA Technical Support.

GSVX261E CSVDYNEX REQUEST=<request> failed, exit <exitname> rc <retcode> rs <rsncode>

A request to the Dynamic Exit Services failed.

For more information, see the MVS Authorized Assembler Services Reference.

GSVX262E OBTAIN request for <stgtype> failed, len <len> rc <rc>

A request for storage has failed.

GSVX263E Unable to load Dynamic Exit Module <module>

A attempt was made to load a module for use with dynamic exits. The load failed.

module - Name of module being loaded

GSVX264E Unable to initialize the Dynamic Exit Module

A attempt was made to initialize a dynamic exit load module. The initialization call has failed.

GSVX265W SMF data collection is not active

A request was made to access SMF collected data. Data collection is not active.

GSVX266W Requested data is not available

A request was made for specific data from a collection log. The requested data is no longer available on that log.

GSVX267E SMF record formatting routine <module> was not found

A request was made to format an SMF record. The module used to format the record was not found. The module names are specified by SMF record type in the parmlib member SMFTYPE.

module - Module name

GSVX268E SMF record formatting routine <module> has abended. Routine disabled.

A request was made to format an SMF record. The module used to format the record abended.

module - Module name

GSVX270I H=<hash> L=<length> R=<resource>

An internal trace message used to debug hashed data structures.

GSVX271I <task> connected to log stream <logstream> type <type>

The task has successfully connected to the specified log stream.

GSVX272E Unable to write to file <ddname>

An attempt to write to the specified ddname failed.

GSVX273I Subsystem ID <ssid> not found

A request was made to connect to the specified subsystem ID. The ID was not found.

GSVX280E <var1> not allocated

Informational only.

GSVX281E <var1> devn <var2> not allocated to a display device

Informational only.

GSVX282E <var1> devn <var2> not allocated to a local 3270 display device

Informational only.

GSVX283E Open failed for <var1> devn <var2>

Informational only.

GSVX284E I/O error on <var1> to <var2> devn <var3>

Informational only.

GSVX285E <var1>

Informational only.

GSVX286E Unable to determine devn <var1> screen size - 24x80 assumed

Informational only.

GSVX287E Devn <var1> initialization error <var2> <var3> <var4>

Informational only.

GSVX288E MODIFY command not supported

Informational only.

GSVX289I Devn <var1> senseid <var2>

Informational only.

GSVX290I TSF <owner> <hierarchy> Entities <entities> Metrics <count> Zero <skip>

Metrics data is being sent to the Time Series Facility server for the listed owner and hierarchy. The number entities is a count of unique entity instances at the lowest level.

GSVX291I Address <address> Length <length> <description>

Messages GSVX291 and 292 are displayed with debugging information.

GSVX292I <offset> <+0data> <+4data> <+8data> <+Cdata> <chardata>

Messages GSVX291 and 292 are displayed with debugging information.

GSVX293I TSF Logger process complete <count> buffers processed <count> buffers sent <count> buffers discarded

The TSF task, logger process has completed and the indicated number of buffers were processed, sent and discarded.

GSVX294I TSF PC data send: Blocks <blocks> Data <length>

TSF data is being sent to the TSF logger.

GSVX295W TSF period data bypassed. Interval resynchronized.

TSF period data collection is being resynchronized.

GSVX300E Call to ISPLINK for <serv> service failed - RC=<code>

The ISPF interface has requested ISPF services <serv>, but the request has failed. <code> is the return code. Make sure you are using ISPF Version 2 or higher. If you are, note the return code. Contact CA Technical Support.

GSVX301E <message-text>

An error message was returned by ISPF after a request was made for ISPF services. The message text, <message-text>, is the actual message returned by ISPF.

GSVX302E ISPF panel <panname> not found

The panel <panname> cannot be found. Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX303E ISPF panel <panname> not release <rel> or higher, found <relfnd>

The panel <panname> cannot be displayed because it is not at the correct SYSVIEW release <rel>. Verify that the SYSVIEW ISPF interface is correctly installed. Contact CA Technical Support.

GSVX304E ISPF command table <tabname> not usable by SYSVIEW

The command table <tabname> is either not in the correct format or not at the proper level. Verify that the ISPF interface is correctly installed. Contact CA Technical Support.

GSVX305E ISPF cmd table <tabname> not release <rel> or higher, found <relfnd>

The command table <tabname> cannot be displayed because it is not at the correct SYSVIEW release <rel>. If you are using a supported release, note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX306I To end UPDATE mode press ATTN or press RESET then PA1

Update mode is in effect. To end update mode, do one of the following:

GSVX307I To end UPDATE mode press RESET then PA1

Update mode is in effect. To end update mode, press the RESET key and then the PA1 key.

GSVX308I To end UPDATE mode press ATTN

Update mode is in effect. To end update mode, press the ATTN key.

GSVX309I Dataset saved

The return code from the ISPF EDIT facility indicated that data was saved and either the data set was not a PDS or no member name was specified on the EDIT command.

GSVX310I Member <memname> saved

The return code from the ISPF EDIT facility indicated that data was saved and a specific member name was used with the EDIT command. <memname> is the name of the member that is saved.

GSVX311I END received from ISPF display service

Informational only.

GSVX320E Invalid <member> table entry. <entry>

An entry in parmlib member <member> is invalid.

GSVX321W Threshold [set the product group or family] <name> <argument> <status> V=<value> W=<warn> P=<prob> <ruletype> <elapsed> <asid> <jobid> Desc='<desc>'

A status of an MVS defined threshold limit has changed.

GSVX322E Function request failed. Invalid name

A request was made to add a table entry. The entry name was invalid.

GSVX323E Function request failed. Duplicate name found

A request was made to add a table entry. The entry name already exists.

GSVX324E Request failed RC=<rc>

The request for data failed. Return code <rc>.

GSVX325E Input is required for field "<field>"

The field <field> requires input to process the requested function.

GSVX326W Threshold [set the product group or family] <qmgr|ssid> <name> <argument> <status> V=<value> W=<warn> P=<prob> <ruletype> <elapsed> Desc='<desc>'

A status of a defined threshold limit has changed for the following components: WebSphere MQ, IMS, TCP/IP

GSVX327E Function request failed. Non-generic argument is required.

The argument cannot be specified as a generic or wildcard argument. A threshold was defined with an argument value of "*" or "=". A non-generic argument must be specified.

GSVX328E <value> is invalid for parameter <parm>

The <value> specified is not a valid value to the parameter <parm>.

GSVX329E Function request failed. Invalid parameter

An invalid parameter was specified while defining or changing a threshold entry.

GSVX330W The variable <variable> is obsolete. Entry was not created

A request was made to create a monitoring entry or definition for the variable specified. This variable is obsolete.

<variable> - Obsolete variable name

GSVX331I Metric <name> Rsce1 <rsce1> Rsce2 <rsce2> Rule <rule> XDRB <xrdb> <reason> <status>

Internal debugging message. Contact CA Technical Support for more information if this message is displayed.

GSVX332I WebSphere MQ request <function> RC=<rc> <qmgr> <argument>

A request for WebSphere MQ information has failed.

GSVX333E UNIX System Services <func> failed, rc <rc> rs <rs>

A request to UNIX System Services has failed.

Common errors:

For more information, see the UNIX System Services Error Message Manual.

GSVX334I <component> data collection Elapsed=<elapsed> CPU=<cputime> Start=<startime> End=<Endtime>

A trace message logging the start and end time of a data collection interval.

GSVX335E Dataspace corruption detected in <name> at <address>

Dataspace corruption has been detected.

Informational only.

GSVX336I <event> Elapsed=<elapsed> CPU=<cputime> Start=<startime> End=<Endtime>

A trace message logging the start and end time of a timed event

GSVX337E The variable <variable> is not owned by the <owner> data collector

A request was made to add a threshold, monitoring, or state definition. The requesting commands data collector does not own the requested variable.

Example: The MQTHRESH command tried to add an MVS threshold.

GSVX338E <request> for <variable type> <name> failed. <name> is a <variable type> variable.

A request was made to a threshold, monitoring, or state definition. There is a type mismatch.

Example: The request was made to a threshold variable. Problem was that the variable requested was a state variable an not a threshold variable.

GSVX339I Class: <class Pool: <pool> Cell: <cell>

A data collection diagnostics message.

GSVX340E Unable to connect to the data store <name>

The command entered is trying to connect to the data collection data store.

Possible problems:

GSVX341I <mdceaddr> <variable> <arg> <alias> V=<value> C=<count>

Internal debugging message displaying the current value for a data collection variable. Contact CA Technical Support for more information if this message is displayed.

GSVX342E UNIX System Services kernel is not active

The UNIX System Service has not been successfully initialized. USS is required for the Unicenter agents.

GSVX343E CAICCI is not active

CAICCI is not active. CAICCI is part of CA Common Services.

GSVX345E <request> failed, rc <rc> vrc <vrc> xrc <xrc>

A request to CA Common Services for z/OS has failed. Return code information is provided.

GSVX346E <request> failed, <errtext>

A request to CA Common Services for z/OS has failed.

GSVX347E Server <type> <ident>

This message displays the origin or destination communication server identifier.

GSVX348E Client <type> <ident>

This message displays the origin or destination communication client identifier.

GSVX349E <ddn> ddname allocated to a SYSIN data set

The <ddn> ddname can not be allocated to a SYSIN data set.

GSVX350E Invalid dataset attributes for <ddname> ddname

The batch interface has detected invalid DCB parameters for the <ddname> ddname. For a description of the valid DCB parameters for the SYSPRINT and SYSIN data sets, see the Administrator Guide.

GSVX351E OPEN failed for <ddname> ddname

The batch interface has tried unsuccessfully to the <ddname> ddname. Try running the job again. Contact CA Technical Support.

GSVX352W SCROLL ignored due to previous command error

The SCROLL request was ignored because the previous command generated an error message. Correct the command that caused the error and try running the job again.

GSVX353E Invalid keyword - <keyword-statement>

The batch interface module has encountered the invalid keyword <keyword-statement> while processing the input control cards. The statement is ignored, and processing continues with the next keyword statement. Check the keyword statement and run the job again.

GSVX354E Invalid keyword parameter - <keyword-statement>

The batch interface module has encountered the invalid keyword parameter <keyword-statement> while processing the input control cards. The statement is ignored, and processing continues with the next keyword statement. Check the keyword statement and run the job again.

GSVX355E Mismatched parenthesis - <keyword-statement>

The batch interface module has encountered an unbalanced set of parentheses in processing input control cards. The message shows the entire keyword statement <keyword-statement>. The statement is ignored, and processing continues with the next keyword statement. Correct the keyword statement and run the job again.

GSVX356E Invalid subscript on DATA keyword - <keyword-statement>

The batch interface module finds the subscript on the DATA keyword to be invalid. The message shows the entire keyword statement <keyword-statement>. The statement is ignored, and processing continues with the next keyword statement. Correct the DATA keyword, specifying a valid subscript. Run the job again.

GSVX357E Input field not on display - <keyword-statement>

The batch interface module finds that the subscript on the DATA keyword does not correspond to an input field on the current display. The message shows the entire keyword statement <keyword-statement>. The statement is ignored, and processing continues with the next keyword statement. Correct the DATA keyword, specifying a keyword that corresponds to an input field on the current display. Run the job again.

GSVX358E Input data longer than input field - <keyword-statement>

The batch interface module finds that the input data for an input field is longer than the input field. The message shows the entire keyword statement <keyword-statement>. The statement is ignored, and processing continues with the next keyword statement. Correct the length of the input data and run the job again.

GSVX359E <xxxxxxx> keyword invalid at this time

The EXECBAT module has encountered keyword <xxxxxxx>, which is either not expected or not allowed. If <xxxxxxx> is COMMAND, specify a user ID and password with DATA keywords at the beginning of the input control cards. If <xxxxxxx> is SCROLL, check that the DUMP command is not active. You cannot use the SCROLL command when the DUMP command is active.

GSVX360W Line limit exceeded. Data incomplete

This message is displayed when using the API interface. Not all of the data was returned because the line limit maximum was reached. If more data is required, increase the line limit maximum by using the LIMIT keyword.

GSVX361E Invalid field name or number with INPUT keyword <keyword>

This message is displayed when using the API interface. The keyword <keyword> is not a valid field name or input field number. Change the keyword value to a valid input field name or number.

GSVX362E Value required for keyword parameter - <keyword-statement>

The batch interface module has encountered the invalid statement while processing the input control cards. The statement is ignored, and processing continues with the next statement. Check the statement and run the job again.

GSVX363A Enter batch request or /* to exit

This message is displayed when the batch interface module is invoked in a TSO foreground address space. It requests the user to enter the next batch request to process or the string "/*" to exit the batch interface.

GSVX364A Hit ENTER to continue SCROLL or any Fnn key to stop

This message is displayed when the batch interface module is invoked in a TSO foreground address space and the user has entered the SCROLL statement. It requests the user to hit the ENTER key to continue scrolling or to hit any Fnn key to stop scrolling.

GSVX365E OPEN ddname <ddname> abended, <abncd>

Abend <abncd> occurred attempting to open the ddname <ddname>.

GSVX366E Batch initialization failed, abend <abncd>

Batch initialization failed with abend <abncd>.

GSVX367I Terminated by ATTN

The batch interface was terminated because the user hit the ATTN key. This can only happen if the batch interface was executing in a TSO foreground address space with the SYSIN and SYSPRINT ddnames allocated to the terminal.

GSVX370I CICS logger <taskident> has been <action>

A request has been made to a specific CICS logger named <taskident>.

action values:

GSVX371I <type> linkage index <lx>.<seqno> has been <action>

A request for a linkage index with value <lx> has been made.

GSVX372E <request> request failed. RC=<rc>

The specified request <request> has failed. The return code from the request is indicated by value <rc>.

GSVX373E <request> service failed. STOKEN=<stoken> R15=<r15> R0=<r0>

The specified request <request> has failed. The request was directed at the dataspace with stoken <stoken>. The resulting values for registers 15 and 0 are shown in <r15> and <r0>.

GSVX374I The extended private limit has been increased from <original> to <new>

A request was made to dynamically increase the extended private storage size for the address space.

<original> indicated the size prior to increasing its value to <new>.

GSVX375I Authorization index <ax> has been <action>

A request for a authorization index with value <ax> has been made.

GSVX376I CICS logger <taskident> has recovered inactive jobname <jobname>

The CICS logger task has detected a CICS data collection address space as inactive. A recovery process is performed to resync the collection blocks.

GSVX377I ASN-LX Reuse=<asnlx> DIAG REUSASID=<diag> STC REUSASID=<stc>

The current status of ASN-LX reuse and address space reuse is displayed.

If all of the above values are not YES, then the address space will not be reuseable.

GSVX380I A rule is not defined for the selected entry

The select entry does not have a defined threshold or state rule.

GSVX381I A monitor definition is not required

The a specific monitoring definition is not required for the selected entry.

GSVX382I Routine <routine> Input <input> Output <output>

Internal debugging message displaying the current value for a data collection process. Contact CA Technical Support for more information if this message is displayed.

GSVX383I Data has been exported to <dataset(member)>

A request to export data has been made. The data has been written to the data set and member specified.

GSVX384I Checkpoint data has been saved for <datatype>

A request to checkpoint data has been made.

GSVX385E CA OPS/MVS Event Notification error. RC=<rc> RS=<rs>

An event notification request has been made to CA OPS/MVS that has failed. The return code and reason code is given.

Return code and description:

GSVX386W CA OPS/MVS Event Notification is not available

No CA OPS/MVS subsystem is active to process an event notification request.

GSVX387W CA OPS/MVS Event Notification has been disabled

An event notification request has been made to CA OPS/MVS that has failed. No more attempts will be made. The interface has been disabled.

GSVX390I GDBB <function>. Total=<tot> Min=<min> Max=<max> Entries=<cnt>

Internal log message.

GSVX391I <function> Buffer=<address> Length=<length>

Internal log message.

GSVX392E Data export to <dataset(member)> failed. <reason>

A request to export data has been made. The request has failed. Check reason for additional information.

GSVX393E Checkpoint data request for <datatype> failed. <reason>

A request to checkpoint data has been made. The request has failed. Check reason for additional information.

GSVX394I <type> start has been initiated

A task has been started. The task is being started using a "Warm" or a "Cold" method.

GSVX395I Cursor=(<row>,<col>) Area=(<rowb>,<colb>)(<rowe>,<cole>) Cmd=<command> Keyword=<keyword>

The user has invoked cursor selection within the information or overview section of the display.

GSVX400E SHOWCB for VTAM RPL failed, rc <code>

The SHOWCB macro, used to determine the length of the RPL, has failed. <code> is the return code. Note the return code. Contact CA Technical Support.

GSVX401E Open ACB failed for applid <applid>, rc <code>

The open has failed for the VTAM ACB. The first half of the return code <code> is the contents of register 15 in hexadecimal. The second half of the return code is the hexadecimal error field from the ACB. If the return code is 0008005A, make sure the APPLID is defined to VTAM and is active. Check the VTAM programming manual for the return codes from OPEN for an ACB. For more information, note the return code. Contact CA Technical Support.

GSVX402E SETLOGON failed, rc <code>

The SETLOGON macro has failed in the GSVXVTAM module. <code> is the return code. Note the return code. Contact CA Technical Support.

GSVX403E RPL related failure, rc <code,termid,userid>

An RPL error has occurred for a VTAM interface session. The user may have dropped their session without ending it properly. The return code <code> reflects fields from the RPL when the error occurred. The terminal ID <termid> and user ID <userid> are displayed in the message if they are available. If this message occurs repeatedly, note the return code. Contact CA Technical Support.

GSVX404E <var1> failed, RPLFDBK <var2>

Informational only.

GSVX405I <var1> complete, RPLFDBK <var2>

Informational only.

GSVX406E Open ACB for applid <var1> failed, <var2>

Informational only.

GSVX407I Now accepting logons to APPLID <applid>

The SYSVIEW VTAM has completed initialization and is now ready to accept logons using the <applid>.

GSVX408I Now accepting logons to APPLID <applid> (or network name <netnm>)

The SYSVIEW VTAM has completed initialization and is now ready to accept logons using the <applid> or <netnm> names.

GSVX409E Invalid command - <var1>

Informational only.

GSVX410W Command ignored - <var1>

Informational only.

GSVX411I <var1> command received

Informational only.

GSVX412E No <var1> statement found in <var2> PARMLIB member

Informational only.

GSVX413I Open ACB retry <var1> of <var2> in <var3> seconds

Informational only.

GSVX414I Retry limit reached

Informational only.

GSVX415I Session opened, LU <v1> CID <v2> Logmode <v3> COS <v4> BIND

Informational only.

GSVX416I <v5>

Informational only.

GSVX417I User identified, LU <lunm> Userid <userid>

Informational only.

GSVX418I Task attached, LU <lunm> TCB <tcbaddr>

User session has been attached.

GSVX419I Task detached, LU <lunm> TCB <tcbaddr>

User session has been detached.

GSVX420I Session closed, LU <lunm> CID <cid>

User session has been closed.

GSVX421I User session timeout, LU <lunm> Userid <userid>

User session has been timed out by security. The LUname and userid that was timed out is displayed.

GSVX422I Open ACB complete for applid <applid>

Informational only.

GSVX423I <text>

The text displayed is the output of one of the following console commands.

GSVX430I System log (logical name) not found

The system log data set (logical name) is not defined to this system. The command requesting this log data set is not available on this system.

GSVX431I System log (logical name) not active

The system log data set (logical name) is not active on this system. The command requesting this log data set displays the available data.

GSVX432I No records to display in log stream <logstream>

The log stream <logstream> is empty.

GSVX440E Invalid value specified. Min=<min> Max=<max>

An invalid value has been specified. The acceptable minimum and maximum values are provided.

GSVX441E Invalid <keyword> value specified. Min=<min> Max=<max>

An invalid value has been specified. The acceptable minimum and maximum values are provided.

GSVX442I Topics printed: <count>

A request to print topics has completed.

GSVX443E Invalid value for <parameter>

An invalid parameter value has been specified.

GSVX444E Conflicting requests. Request aborted.

A request was made to set a value. More than one function was requested. The entire request has been aborted.

GSVX445E Configuration member: <member>
GSVX446E Configuration option: <statement>
GSVX447E Configuration error : <reason>

An error has occurred while processing a parmlib member that contains configuration options.

GSVX448I Configuration default: <keyword> <value>

A default value is being set for the configuration keyword.

GSVX449I Collection variable <source> <variable> <action>

The specified action has been taken against the data collection variable.

GSVX450I FixLvl <fixlvl>

Informational only.

GSVX451E Abend <code description>

Informational only.

GSVX452I <product-name> <mode> <cntl> control at entry to abend

Informational only.

GSVX453I Diagnostics for <mode> in control at entry to abend

Informational only.

GSVX454I Diagnostics for <product-name> TCB/RB at last interrupt

Informational only.

GSVX455I General registers at entry to abend

Informational only.

GSVX456I General registers at time of interrupt

Informational only.

GSVX457I Psw <psw> Ilc <ilc> Intc <intc>

Informational only.

GSVX458I <type> <name> Addr <addr> Offset <offset>

Informational only.

GSVX459I Data at PSW addr <addr>

Informational only.

GSVX460I <word-1> <word-2> <word-3>

Informational only.

GSVX461I <regs word-1 word-2 word-3 word-4>

Informational only.

GSVX462I End of symptom dump

Informational only.

GSVX463I No active load module found

Informational only.

GSVX464E Abend <code> at addr <addr> module <name> offset <offset>

Informational only.

GSVX465E Abend <code> at addr <addr> in <name>+<offset> user <userid>

Informational only.

GSVX466E Abend <cmc> in recovery <descr> processing routine

Informational only.

GSVX467I <regs> <value1> <value2>

Informational only.

GSVX468I Dump scheduled to ddname <ddname>

Informational only.

GSVX469I No dump scheduled - <reason>

Informational only.

GSVX470I Attention interrupt occurred at <addr>

Informational only.

GSVX471E <cmdnam> terminated by attention

Informational only.

GSVX472I Userid <userid> Terminal <term> Interface <intfc>

Informational only.

GSVX473I Routne <rtnenam> Addr <addr> Offset <offst>

Informational only.

GSVX474I Retry to <name> module <modnam> offset <offst> routine <rtnenm>

Informational only.

GSVX475I Access registers at entry to abend

Informational only.

GSVX476I Access registers at time of interrupt

Informational only.

GSVX477I Key <ky> State <st> Am <am> Asc [assign the value for ASC in your book]

All of these messages are part of the diagnostic data SYSVIEW issues when it abends. If any of these messages are issued, note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX478I Retry not <requestd|allowed>, calling cleanup exit

Informational only.

GSVX479I <address> module <module> offset <offset> routine <routine>

Informational only.

GSVX480I Cleanup exit complete

Informational only.

GSVX481I Cleanup exit failed

Informational only.

GSVX482I <taskname> task abnormal termination in progress

Informational only.

GSVX483I Some other task requested STEP abend

Informational only.

GSVX484I Abend occurred in an ancestor task

Informational only.

GSVX485I <taskname> task abnormal termination complete

Informational only.

GSVX486A <optname> option in effect, hit ENTER to continue

Informational only.

GSVX487I Error info <xx.xx.xx.xx.xx.xx.xx.xx>

Informational only.

GSVX488I <modname> <rtnname> <type>, mode <mode> key <key> SDWA key <key> level <level> opts <opts>

Informational only.

GSVX489I SDWA <sdwaaddr> RRXB <rrxbaddr> DSA <dsaaddr>

Informational only.

GSVX490E The <cmnd> command does not support block commands

Informational only.

GSVX491E The <cmd>.<scr> command does not support block commands

Informational only.

GSVX494A Userid access has been revoked

Informational only.

GSVX495E <resp> confirmation response not allowed

Informational only.

GSVX496E <resp> confirmation response parameter not allowed - <errparm>

Informational only.

GSVX497E @<8> confirmation response parameter not valid - @<32>

Informational only.

GSVX498A Userid not defined

Informational only.

GSVX499A Userid not defined or access revoked

Informational only.

GSVX500I <userid> was denied the <command> command for <restype resvalue>

User <userid> attempted to use the command <command> for resource type <restype> with a resource value of <resvalue> but was denied. The message action is set for this resource. For details on setting the message action for a resource, see the Security Guide.

GSVX501I <userid> was denied use of <restype resvalue>

User <userid> attempted to use the resource type <restype> with a resource value of <resvalue> but was denied. The message action is set for this resource. See the Security Guide for details on setting the message action for a resource.

GSVX502I <userid> used <restype resvalue>

User <userid> used resource type <restype> with a resource value of <resvalue>. The message action is set for this resource. For details on setting the message action for a resource, see the Security Guide.

GSVX503E Invalid character delimiter usage in <parmnm> parameter

Informational only.

GSVX504W End of command input stack

Informational only.

GSVX505I No authorized <xxxxxxxx> to display

This message is displayed when there is no authorized data to display. The security rules determined that no data should be displayed.

GSVX506E Too many discontiguous VL mask chars - <errorstring>

A maximum of 8 discontiguous variable length masking character is allowed. This limit was exceeded.

GSVX507E Internal error <variable>

An internal error occurred during processing. Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX508E Invalid request, SYSVIEW not activated via a CLIST or REXX exec

The requested function is only available when executed using a CLIST or through the REXX exec API.

GSVX509E <func> function failed, rc <rc> rs <rs> key <key>

An attempt to dynamically add or delete OUTPUT JCL statement values failed. funcname is OUTADD or OUTDEL. Note the circumstances in which the error occurred. Contact CA Technical Support.

GSVX510E Maximum length of input from a cleared screen is 256

An input data stream longer than 256 characters was received from a cleared screen. The input is rejected.

GSVX511I Request complete: <string>

This is a generalized message used to indicate that some requested function has been successfully completed.

GSVX512I Output file not available

An attempt to display an output file failed because the output file could not be found. The output file could have been deleted.

GSVX513E Invalid subcommand - <errordata>

The specified data is not a valid subcommand.

GSVX514E Invalid <dsnparmname> - <errordata>

The specified data is not a valid data set name.

GSVX515A Command input pending - Continue and ENTER or hit any PF key to clear

The current command input string ended with the command continuation character. Any data entered has been added to the pending command string. Continue to enter the rest of the command or use any PF key to discard the entire command.

GSVX516I Pending command input cleared

A PF key was entered in response to message GSVX515I. The pending command input has been cleared.

GSVX517E Maximum command length of 256 exceeded

The total maximum command length of 256 characters has been exceeded.

GSVX518E Cursor not within data rows

An explicit cursor data character was encountered in the command input string but the cursor was not positioned within the data rows.

GSVX519E Unable to determine cursor location data

An explicit cursor data character was encountered in the command input string but the cursor location data could not be determined.

GSVX520E Nothing found at cursor location

An explicit cursor data character was encountered in the command input string but nothing was found at the cursor location.

GSVX521W <command> terminated by ATTN

The indicated command has been terminated prematurely by hitting the ATTN (or PA1) key.

GSVX522E Invalid CP command: <errcmd>

Informational only.

GSVX523E Invalid <fldname> field value - <errordata>

Invalid data was entered in the indicated field.

GSVX524A Value in <fldname> field required

A value must be entered in the indicated field.

GSVX525E Invalid <var1> parameter - <var2>

Informational only.

GSVX526E Highlighted parameter line input fields are invalid

Informational only.

GSVX527E Highlighted data line input fields are invalid

Informational only.

GSVX528E <func> failed, abend <abncmc>

Informational only.

GSVX529E <func> failed, rc <rtncd> rsn <rsncd>

Informational only.

GSVX530E DDname <ddnm> not allocated

Informational only.

GSVX531E <func> unavail at <pgm> <lvl1>, lower than <lvl2> reqd

Informational only.

GSVX532E <func> failed, rc <rtncd>

A request to the specified function has failed. The return code should be used to determine the reason for failure. Additional messages may be present.

GSVX533E <var1>

Informational only.

GSVX534E CP command failed, rc <rtncd> - <var2>

Informational only.

GSVX535A <pswdpos> password length invalid. Reenter password

During user logon, the first or second (pswdpos) password entered was too long. Passwords must be no more than eight characters long.

GSVX536A <Password|Passphrase> is not authorized. Reenter <password|passphrase>

During user logon, the password or passphrase entered was not correct. Enter the correct password or passphrase to continue. If you are using a passphrase, ensure your logon id has the passphrase attribute.

GSVX537A <Password|Passphrase> has expired, enter new <password|passphrase>

The password or passphrase entered during user logon has expired. Enter a new password twice separated by a slash. The second password is required to verify the first one. For a passphrase, enter it twice in the designated fields on the User Identification logon screen.

GSVX538A New <password|passphrase> invalid

The security system rejected the new password or new passphrase. For passwords, reenter the new password twice separated by a slash. For passphrases, enter it twice in the designated fields on the User Identification logon screen. Passphrases can be 14-100 characters in length. If you are specifying a passphrase length between 9 and 13 bytes, the ICHPWX11 exit must be present.

GSVX539E User's access has been revoked. Session terminated

The user ID used when logging on has been revoked by the external security system. Contact your security administrator to reinstate the user ID.

GSVX540E SAF user authentication failed. SAF rc <rc> RACROUTE rc <rc>, rs <rs>

An attempt to validate a user through the SAF interface failed. SAF and RACROUTE return codes are supplied in the message along with the RACROUTE reason code. Check the external security product manuals for the reason the request failed. For RACF, the External Security Interface (RACROUTE) Macro Reference manual has an explanation of the return and reason codes.

GSVX541E Request/Return job ID failed, rc <rc> rs <rs>

An attempt to obtain a job ID from JES failed. Note the return and reason codes in the message. Contact CA Technical Support.

GSVX542I JES services are not available

A command was entered that requires JES services, but they are not available now. Try again later when the JES subsystem is active.

GSVX543E Invalid user ID. Logon terminated

The user ID used when logging on has not been defined to the external security system. Contact your security administrator to get the user ID defined.

GSVX544E Invalid <var1> dataset record length, <var2> found, <var3> required

Informational only.

GSVX546I Request complete: <var1>

Informational only.

GSVX547E <var1> <var2> <var3> <var4> <var5>

Informational only.

GSVX548W <scrlcmd> command not supported on <cmd> display

The scroll command <scrlcmd> is not supported on the <cmd> command display.

GSVX549E <var1> failed - abend <abncmd>

Informational only.

GSVX550E IOERROR <var1>

Informational only.

GSVX551W Invalid variable name - <var1>

Informational only.

GSVX552W Variable not defined - <var1>

Informational only.

GSVX553W Truncation occurred during variable substitution

Informational only.

GSVX554E <var1> failed. <var2>

Informational only.

GSVX555E <idn> NSS-PC error, "GETMAIN RC,LV=<len>,SP=<spn>,LOC=<loc>" failed

An attempt was made to acquire CSA or SQA storage, but there was not enough contiguous storage available to satisfy the request. Use the COMMON command to determine if common area storage is fragmented or exhausted. The <idn> variable is a NSS-PC identifier which can be JCSR, ROSR, or XMDS. <len>, <spn>, and <loc> are the length, subpool number and location of the storage requested.

GSVX556I Enter <cmdnam> command with a valid option

Informational only.

GSVX557E Module <modnam> not loaded from an APF authorized library

Informational only.

GSVX558I Completion code checking <enabled/disabled>

This message is displayed by the SYSVIEW JOBS task when using the CCODE or NOCCODE parameter. It displays the status of completion code information checking.

GSVX559E Invalid <var1> parameter: <var2>

Informational only.

GSVX560E Screen overflow - <1> pfkey, divider, info, or hdr rows suppressed

Informational only.

GSVX561E <var1> <var2> command requires <var3> feature

Informational only.

GSVX562E <var1> parameter required for <var2> <var3> command

Informational only.

GSVX564W <var1> buffer overflow, display truncated

Informational only.

GSVX565W Nonstandard local date/time offset (CVTLDTO), user TIMEZONE ignored

Informational only.

GSVX566W <var1> is no longer supported, please use the <var2> command

Informational only.

GSVX567E <dsntype> member <name> was not found in DSN <dataset>

The requested member name could not be found in the specified data set.

GSVX568E Invalid date parameter - <dateparm> - <reason>

Informational only.

GSVX569E Invalid time parameter - <timeparm> - <reason>

Informational only.

GSVX570I <taskid> task initialization started

Informational only.

GSVX571I <taskid> task initialization complete

Informational only.

GSVX572E <taskid> task initialization failed

Informational only.

GSVX573I <taskid> task termination started

Informational only.

GSVX574I <taskid> task termination complete

Informational only.

GSVX575W <task> task termination will be forced

During product shutdown, the specified <task> did not terminate in the allowable amount of time. The task is forced to terminate.

GSVX576I <var1> event processing started

Informational only.

GSVX577I <var1> event processing ended

Informational only.

GSVX578I Anchor block <var1> at <var2>

An anchor block has been located at the specified address.

GSVX579W <var1> command invalid in startup parms PARMLIB member <var2>

Informational only.

GSVX580E Invalid command in PARMLIB member <var1>1:

Informational only.

GSVX581E Invalid command received from console:

Informational only.

GSVX582E Invalid command - <var1>

Informational only.

GSVX583E Invalid <var1> command parms - <var2>

Informational only.

GSVX584E Task name required for <var1> command

Informational only.

GSVX585E Invalid task name for <var1> command - <var2>

Informational only.

GSVX586E <var1> <var2> invalid, <var3>

Informational only.

GSVX587E <var1> <var2> parms not allowed - <var3>

Informational only.

GSVX588I <var1> option <var2>

Informational only.

GSVX589W <var1> option already <var2>

Informational only.

GSVX590W @<8> @<17> rejected, task busy

Informational only.

GSVX591I <var1> <var2> scheduled

Informational only.

GSVX592W <var1> <var2> <var3>

Informational only.

GSVX593E <var1> <var2> failed, ATTACH rc <var3>

Informational only.

GSVX594I <var1> task <var2>

Informational only.

GSVX595I <var1> command accepted

Informational only.

GSVX596W Task name <var1> is not unique - Use task identifier

Informational only.

GSVX597E <var1> <var2> not valid in <var3> address space

Informational only.

GSVX598E <var1> command not supported by <var2> task

Informational only.

GSVX599E <var1> <var2> not valid without JES

Informational only.

GSVX600E Invalid <var1> task command - <var2>

Informational only.

GSVX601I <var1> <var2> <var3> <var4> <var5>

Informational only.

GSVX602I <var1>

Informational only.

GSVX603I <var1> <var2> parms received - <var3>

Informational only.

GSVX605E Line command required on either begin block or end block

Informational only.

GSVX606I Block command entered on lines <v1> and <v2> (<v3> total lines)

Informational only.

GSVX607I Block command pending on line <v1>

Informational only.

GSVX608E Conflicting begin and end block input (lines <v1> and <v2>

Informational only.

GSVX609E Block command internal error - <errtxt>

Informational only.

GSVX610A Enter YES to confirm all <v1> line commands

Informational only.

GSVX611E Rename task <old> to <new> not possible, new name already in use

Informational only.

GSVX612I Task <var1> <var2>

Informational only.

GSVX613I Task <var1> renamed to <var2>

Informational only.

GSVX614I <vartxt>

Informational only.

GSVX615I Validating <var1> LMP code <var2>

Informational only.

GSVX616I <var1> feature enabled

Informational only.

GSVX617E LMP code validation service unavailable, some commands may not be available

Ensure that CA Common Services has completed initialization before starting the product. Only MVS related features will be available.

GSVX618E Module <var1> not found

Informational only.

GSVX619E <var1> not installed

Informational only.

GSVX620E Internal error, invalid feature code: <var1>

Informational only.

GSVX621E @<8> interface not available - No interactive features validated

Informational only.

GSVX622I LMP code validation <status>

Indicates the current status of the LMP validation process.

GSVX623I ATTACH time last @<16> curr @<16> diff @<8> task @<8> wait @<8>

Informational only.

GSVX630I System <var1> IPLed <var2> at <var3>, type <var4>

Informational only.

GSVX631I <vartxt> <mbrnm> parmlib member

Informational only.

GSVX632I <vartxt> <mbrnm> initial START commands

Informational only.

GSVX633E <opt1> option invalid, <opt2> already specified

Informational only.

GSVX634I <optn> option <vartxt>

Informational only.

GSVX635W <optn> option already <vartxt>

Informational only.

GSVX636I No PRIMARY or SECONDARY option found, SECONDARY assumed

Informational only.

GSVX637I <tskid> task attached

Informational only.

GSVX638I <tskid> task detached

Informational only.

GSVX639E <cnmd> command only valid for primary address space

Informational only.

GSVX640I <vartxt> automatic START commands

Informational only.

GSVX641I Capture <mbrnm> scheduled

Informational only.

GSVX642I <cmnd> command received from console <cnslname>

Informational only.

GSVX643E CAPLIB member name required

Informational only.

GSVX644E Invalid CAPLIB member name - <mbrnm>

Informational only.

GSVX645E Member @<8> not found in site or system CAPLIB library

Informational only.

GSVX646E Value required for <keywd> keyword

Informational only.

GSVX647W <cnmd> <tsknm> invalid, AUTOSTART not set

Informational only.

GSVX648I <cmnd> <tsknm> complete, AUTOSTART cleared

Informational only.

GSVX649I <cmnd>

Informational only.

GSVX650E Jobname <jobnm> already active, duplicate jobnames not allowed

Informational only.

GSVX651E Task identifier required to start task name <taskname>

Informational only.

GSVX652I AUTOSTART <taskname> ignored, <reason>

Informational only.

GSVX653I <action> <taskname> invalid, required feature not enabled

Informational only.

GSVX663I <tasknm> task <ecbnm> ECB posted

Informational only.

GSVX664I <tasknm> task waiting for work

Informational only.

GSVX665I Waiting for <nnn> minutes or for STOP command

Informational only.

GSVX666I <cmd> command from console <consname> ignored

Informational only.

GSVX667I INTRDR allocated to ddname <ddn>

Informational only.

GSVX668I Submitting JCL to preallocated INTRDR ddname <ddn>

Informational only.

GSVX669E @<8> @<17> command requires parameters

Informational only.

GSVX670E Invalid EXEC PARM string parameters

Informational only.

GSVX671I No COLDSTART or WARMSTART option found, WARMSTART assumed

Informational only.

GSVX672W <starttype> option ignored for address space type SECONDARY

Informational only.

GSVX673I Phase <num> subtask shutdown started

Informational only.

GSVX674I <taskname> posted for shutdown

Informational only.

GSVX675I Phase <num> shutdown complete

Informational only.

GSVX676I Starting subtasks

Informational only.

GSVX677I Phase <num> subtask startup started

Informational only.

GSVX678I Phase <num> subtask startup complete

Informational only.

GSVX679I Subtask startup complete

Informational only.

GSVX681I Parallel <txt> limit of <n> reached, pausing for <n> seconds

Informational only.

GSVX682I @<8> task work complete, active time <elptime> cpu time <cputime>

Informational only.

GSVX683I <taskid> waiting for work

Informational only.

GSVX684I <taskid> task posted, wait time <elptime> post count <cnt>

Informational only.

GSVX685I <taskid> task <ecbname> ECB posted

Informational only.

GSVX686I <modname> <rtnname> routine entered

Informational only.

GSVX687I <tskid> task anchor cleanup complete - <fld1> <fld2> <fld3> <fld4>

Informational only.

GSVX688I <id> anchor cleanup <action>

Informational only.

GSVX689I Activate address space resource manager started

Informational only.

GSVX690I Activate address space resource manager complete

Informational only.

GSVX691I Activate address space resource manager not required

Informational only.

GSVX692E Activate address space resource manager failed, @<32>

Informational only.

GSVX693I <tasknm> task <ecbnm> ECB posted, initialization aborted

Informational only.

GSVX694W <taskid> task request processing CPU time threshold exceeded (<cputime> GT <cputhresh>)

The CPU time that the <taskid> task consumed processing a request exceeded the request processing CPU time threshold.

GSVX695W <taskid> task request processing elapsed time threshold exceeded (<cputime> GT <cputhresh>)

The elapsed time that the <taskid> task spent processing a request exceeded the request processing elapsed time threshold.

GSVX700I WebSphere MQ event management for Qmgr <qmgr> <status>

Event management is starting or stopping for the specified queue manager. Event messages are passed to Unicenter.

GSVX701I WebSphere MQ event management for Qmgr <qmgr> completion code <code>

Event management has terminated. The completion code for the task is provided.

GSVX702I WebSphere MQ monitoring for Qmgr <qmgr> <status>

Information involves the current status of monitoring for a specific queue manager.

GSVX710E <variable> is not eligible for monitoring

A request was made to define monitoring for the specified variable. The variable specified is not variable that monitors a group resource.

GSVX711E <task> data collection not available, required feature was not authorized

An attempt was made to start a data collector. The feature required for the data collection was not requested in the system configuration parmlib member.

GSVX712I <component> threshold initialization complete

Threshold and exception initialization has been completed for the specified component.

GSVX713I SMFDATA collection active for product records only

The SMF data collection process will only collect records created by SYSVIEW.

GSVX714I Set request ignored. No parameters provided.

A request was made to set a value. No parameter value was provided.

GSVX715I Set request has been processed

The requested function has been processed.

GSVX716E Conflicting requests. Request aborted.

A request was made to set a value. More than one function was requested. The entire request has been aborted.

GSVX717E Set request ignored. No function provided.

A request was made to set a value, but a specific function was not requested.

GSVX718E <value> is invalid for function <function>

The value specified is not valid for the function.

GSVX719E <function> is invalid for object <object>

The function specified is not valid for the object.

GSVX730E Member <mbrn> invalid )INCLUDE, member name required

Informational only.

GSVX731E Member <mbrn> invalid )INCLUDE, invalid member name <errnam>

Informational only.

GSVX732E Member <mbrn> )INCLUDE <inclnam> invalid, circular definition

Informational only.

GSVX733E Member <mbrn> )INCLUDE <inclnam> failed, member not found

Informational only.

GSVX734E Member <mbr> )INCLUDE <incl> failed

Informational only.

GSVX735W Entry cannot be expanded or collapsed.

An attempt was made to expand or collapse an entry that is not a group or does not contain any lower level entries.

GSVX736E Recursive call to <modnam> not permitted

Informational only.

GSVX737E <id> req <rq> failed in ASID <asid>, rc <rc> rs <rs> ec <err1> <err2>

Informational only.

GSVX738E Unrecognized parameter - <errparm>

Informational only.

GSVX739I <cmdname> options: <opt1> <opt2> <opt3> ... <optn>

This general purpose informational message lists the options in effect for the command <cmdname>. This message is typically generated in response to an OPTIONS subcommand.

GSVX742E Required TSO/REXX services not available

Informational only.

GSVX743I IMSid <ssid> command: <cmdtext>

The message echoes the command that has been issued.

GSVX744I <p1> echo of member <member>

If the keyword )ECHO has been processed within a source member, the data lines processed are echoed to the log. This message marks the beginning and ending of the echo process.

<p1> will contain Being or End.

GSVX745I <member> <data-text>

This message is produced when echo processing is active for a specific source member.

GSVX746E Syntax error in parmlib member <member> | <text>

A syntax error was found while reading the parmlib member <member>. The statement containing the error is displayed in <text>.

GSVX747E <cnmd> command not valid at ESAME architecture level

Informational only.

GSVX748I Begin <cnmd> display

Informational only.

GSVX749I Event <event> Elapsed <time> CPU <cpu>

An internal statistical message used to evaluate the resources used by an event.

GSVX750E GETMAIN failed, ds [assign the value for DS in your book] alet <alet> len <len> loc <loc> rc <rc>

A request to obtain storage from a dataspace has failed.

GSVX751E FREEMAIN failed, ds [assign the value for DS in your book] alet <alet> addr <addr> loc<loc> rc=<rc>

A request to free storage from a dataspace has failed.

GSVX752I Dataspace <name> has been created, name=<iname>

A new dataspace has been created.

GSVX753I ALET <function> TCB <tcb> ASCB <ascb> SToken <stoken> ALET <alet>

A new ALET has been added to the dispatchable unit access list for the TCB.

GSVX754I Cell <action> <address> Metric <metric> Rsce <rsce>

An action has been taken on a data collection control area.

Internal debugging message. Contact CA Technical Support for more information if this message is displayed.

GSVX760I XLC Command=<cmd> Screen=<screen> LineCmd=<lcmd> Source=<source>

An external line command is being processed.

GSVX761I XLC Field=<field> Data=<data>

The external line command processor will replace the <field> with the specified <data> value.

GSVX762E XLC Field=<field> not found in format

The external line command processor found a substitution field that is invalid.

GSVX763E Invalid command <command> found in external definition

The external line command processor attempted to execute an invalid command.

GSVX764W <linecmd> is not valid for <command> screen type <screen>

The line command entered is not valid for the command and screen. The line command is valid for a different screen type associated with the command.

GSVX765E XLC REXX exec name is required

An external line command (XLC) definition has specified that a REXX exec will generated the command string to be used. The REXX exec name was not specified.

GSVX766E XLC REXX exec name @<8> is invalid

An external line command (XLC) definition has specified that a REXX exec will generated the command string to be used. The REXX exec name is not a valid exec name.

GSVX767I XLC REXX result: <result>

An external line command (XLC) definition has specified that a REXX exec will generate the command string to be used. The message displays the resulting command string.

GSVX768E XLC REXX exec @<8> failed

An external line command (XLC) definition has specified that a REXX exec will generate the command string to be used. The REXX exec failed.

GSVX769E XLC REXX exec @<8> did not return a command and parameters

An external line command (XLC) definition has specified that a REXX exec will generate the command string to be used. The REXX exec did not return a command string.

GSVX789E #PCSERV DEFINE failed, rc <retcd> rs <rsncd>

The #PCSERV DEFINE macro issued to define the NSS-PC failed with return code <retcd> and reason code <rsncd>. Note the circumstances in which the error occurred and contact CA Technical Support.

GSVX790I NSS-PC <defined|redefined>

A #PCSERV DEFINE macro was issued to either define or or redefine the NSS-PC (NonSpaceSwitch-PC).

GSVX791I NSS-PC token <tkn> NPCI epa <npciepa> NPCS epa <npcsepa>

This message displays information about the SYSVIEW NSS-PC (NonSpaceSwitch-PC). It shows the token, the epaddr of the NPCI module and the epaddr of the NPCS module.

GSVX792I NSS-PC already active and no NPCI change

This message indicates that the SYSVIEW NSS-PC has already been installed and that no changes were made that required a re-installation.

GSVX793E Invalid <modname> module identifier

No valid module identifier could be located for the module named <modname>. This message will be followed by another message that displays the 1st 16 bytes of the module in hex. This is where the module identifier should have been located. Note the circumstances in which the error occurred and contact CA Technical Support.

GSVX794I <hexw1>.<hexw2>.<hexw3>.<hexw4>

This message displays the 1st 16 bytes of a module whose module identifier information was not valid. This message is preceded by a message that displays the name of the module. Note the circumstances in which the error occurred and contact CA Technical Support.

GSVX795I <modname> already loaded to LPA

The module named <modname> is required to be located in LPA and it was found to be there.

GSVX796I <modname> loaded to LPA

The module named <modname> is required to be located in LPA. It was loaded to LPA because it was not found already in LPA.

GSVX798E Found <rels> <bld>, need <rels> <bld>

A module named in a previous message was found to have an invalid release and/or build number. This message shows the release and build found and the release and build required.

GSVX799E Invalid <modname> module release/build

The module name <modname> was found to have an invalid release and/or build number. This message is followed by a message that displays the release and build found and required.

GSVX800I <modname> <rels> <bld> ccc <fixlvl> <asmdttm>

This message displays information about the NSS-PC (Non SpaceSwitch-PC) installation service routine. The data displayed is:

GSVX801I Modules will be loaded from DD name <ddname>

This message displays the DD name from which the modules will be loaded.

GSVX802E No STEPLIB or JOBLIB DD allocated

Informational only.

GSVX803E OPEN failed for DD name <ddname>

An attempt to open the ddname <ddname> failed.

GSVX804E Module <modname> not found in DD name <ddname>

A BLDL issued to search for the module named <modname> in the ddname <ddname> returned a module-not-found return code.

GSVX805E BLDL I/O error searching for <modname> in DD name <ddname>

A BLDL issued to search for the module named <modname> in the ddname <ddname> returned an I/O error return code.

GSVX806E LOAD <modname> failed, <abncd>

A LOAD macro issued to load a module named <modname> failed with abend code <abncd>

GSVX807E CAAT (CAAnchorTable) not found

The CAAT (CAAnchorTable) was not found.

GSVX808E Tasklib DD <ddn> not supported, must be STEPLIB, JOBLIB, or LINKLIST

The dynamic installation of the NSS-PC (NonSpaceSwitch-PC) does not support a task library DDname of <ddn>. Only a task library ddname of STEPLIB or JOBLIB is supported. If there is no STEPLIB or JOBLIB task library DDname then the required modules will loaded from LINKLIST.

GSVX809I BLDL <name> <ddn> <dcb> <ttr> <concat> <flag>

This is a diagnostic message generated by the NSS-PC dynamic installation routine. It displays the results of a BLDL macro issued for an NSS-PC module. The data displayed includes:

GSVX810I LOAD <name> <ddn> <dcb> <epa> <lpa> <len>

This is a diagnostic message generated by the NSS-PC dynamic installation routine. It displays the results of a LOAD macro issued for an NSS-PC module. The data displayed includes:

GSVX811I LINKLIST dsname <dsn> volser <vol>

This is a diagnostic message generated by the NSS-PC dynamic installation routine. It displays the LINKLIST data set name and volser that the NSS-PC modules will be loaded from.

GSVX812E Allocate dsname <dsn> volser <vol> failed

This is a diagnostic message generated by the NSS-PC dynamic installation routine. When a LINKLIST data set is the source of the module that must be loaded the data set needs to be dynamically allocated and this dynamic allocation failed.

GSVX813I Testing tasklib DD name <ddname> for SYSVIEW modules

This is a diagnostic message generated by the NSS-PC dynamic installation routine. It is issued before testing a tasklib DD name to see if it contains SYSVIEW modules.

GSVX814I SGAT (SystemGlobalAnchorTable) <found/built> at <addr>

The SYSVIEW SGAT (SystemGlobalAnchorTable) was either found or build at the address <addr>.

GSVX815E STORAGE OBTAIN in ESQA failed for SGAT

An attempt to get storage in ESQA for the SGAT (SYSVIEW SystemGlobalAnchorTable) failed.

GSVX828E SGAT (SystemGlobalAnchorTable) not found

The SYSVIEW SGAT (SystemGlobalAnchorTable) was not found.

GSVX829I <modname> ended, rc <retcd>

The the NSS-PC (NonSpaceSwitch-PC) installation service routine named <modname> completed with return code <retcd>.

GSVX839E Module @<8> not found in LPA after load to LPA successful

The module named <modname> was successfully loaded to LPA using the CSVDYLPA service but a subsequent search for the same module name using CSVQUERY failed to find the module.

GSVX841E CSVQUERY <modname> failed, rc <retcd>

A CSVQUERY macro issued for module <modname> failed with return code <retcd>.

GSVX842I <modname> module <defined|replaced|already defined> in SGAT

The module named <modname> was defined, replaced, or already in the SGAT (SYSVIEW SystemGlobalAnchorTable).

GSVX843I <modname> <rel> <bld> (<fixlvl>) epa <epa> lpa <lpa> len <len>

This message displays the following information about a module:

GSVX844E CSVDYLPA failed loading @<8>

A CSVDYLPA macro issued to load the module named <modname> to LPA failed. This message will be following by another message containing details about the failed CSVDYLPA macro.

GSVX845E CSVDYLPA rc <rtcd> rs <rscd> ec <ec1> <ec2> <ec3> <ec4>

A CSVDYLPA macro issued to load the module to LPA failed. This message displays the return code, reason code, and error codes. A preceding message displays the name of the module for which the CSVDYLPA failed.

GSVX847I Replaced module

This message indicates that an NSS-PC (NonSpaceSwitch-PC) module was replaced. This message is followed by another message that displays the details of the replaced module.

GSVX848I Assemble date and time not equal

This message indicates that an NSS-PC (NonSpaceSwitch-PC) module was replaced because the assemble date and time of the module found in the load library was different from the module found in LPA.

GSVX850I IMS logger environment enabled

The IMS logger intercepts have been initialized.

GSVX851I IMS logger environment disabled

The IMS logger intercepts have been removed.

GSVX852I IMS subsystem <ssid> log capture initialized

The IMS log capture intercepts have been initialized for the specified IMS subsystem.

GSVX853I IMS subsystem <ssid> log capture terminated

The IMS log capture intercepts have been terminated for the specified IMS subsystem.

GSVX854E IMS logger environment not enabled

An attempt was made to start an IMS logger for an IMS subsystem. The global IMS logger environment has not yet been enabled or has previously failed. See prior messages.

GSVX855E IMS subsystem <ssid> is excluded from monitoring

An attempt was made to start an IMS logger for the specified IMS subsystem. This subsystem has been defined as not to be monitored. Logger initialization terminates.

GSVX856I <taskid> logger stats: Records <count> Elapsed <time> CPU <cpu>

An internal trace message used to indicate IMS logger performance statistics.

GSVX857E IMS logger <type> RESMGR not established, rc <rc>

The IMS logger resource manager could not be established.

GSVX858I IMS logger <taskid> is being autostarted for subsystem <ssid>

The IMS logger task is being automatically started for the IMS subsystem.

GSVX859W IMS subsystem <ssid> is not active

An IMS logger task was started. The IMS subsystem was not active.

GSVX860E IMS subsystem <ssid> is a DB only subsystem

An IMS logger task was started for a DB only subsystem.

GSVX861E IMS subsystem <ssid> release <release> is not supported

An IMS logger task was started for an IMS release that is not supported.

GSVX862I IMS subsystem <ssid> log capture active

The IMS logger intercepted have been activated for the specified subsystem.

GSVX863I IMS subsystem <ssid> log capture inactive

The IMS logger intercept and task have been deactivated for the specified subsystem.

GSVX864E Invalid jobname <jobname> for dataspace ownership, rc <rc>

The IMS logger task attempted to use a dataspace that was not owned by the correct jobname.

GSVX865E IMS log record dataspace <name> CREATE failed, rc <rc>

The IMS logger task attempted to create a dataspace. The request failed.

GSVX866E IMS <ssid> intercept plant failed; R15 <r15>

An attempt to initialize the IMS logger intercepts failed. Also see message GSVX867E and GSVX868E.

GSVX867E RetCode = <rc> RsnCode = <rs>

An attempt to initialize the IMS logger intercepts failed. Also see message GSVX866E and GSVX868E.

GSVX868E ErrCode1 = <err> RetReg15 = <r15>

An attempt to initialize the IMS logger intercepts failed. Also see message GSVX866E and GSVX867E.

GSVX869E IMS subsystem <ssid> DC MONITOR is already stated

The DC monitor was already active within the IMS subsystem. The logger could not be activated. The logger can be activated once the DC monitor has been turned off.

GSVX870I IMS trans <tran> <text>

IMS logger trace and debugging message.

GSVX871E Invalid logger name <logger>, IMSID <imsid>

An IMS logger has been started with the task name <logger>. The logger name is invalid. The logger name must follow the naming convention IMSssid. The first three characters of the logger name must be IMS followed by the subsystem of the desired IMS.

GSVX872E IMS subsystem <ssid> log capture failure

The IMS log capture intercept has been terminated due to a failure. The IMS intercept is suspended and the IMS logger task is abended with a U0011 abend code.

GSVX873I New IMS logger environment successfully allocated

A new IMS logger environment structure has been allocated during IMSDATA task initialization. This is an informational only message.

GSVX874E IMS subsystem <ssid> logger initialization error. RetCode=<retcode>

An error occurred during IMS Logger task initialization. The return code will supply additional diagnostic information. Contact CA Technical Support.

GSVX875I IMS subsystem <ssid> logger initialization completed

The IMS logger task for the IMS subsystem indicated has successfully initialized. This is an informational only message.

GSVX876I <taskid> task terminating, completion code = <retcode>

The IMS Logger task processing has terminated normally or abnormally. A completion code exceeding "4" indicates an abnormal condition.

The condition code will supply additional diagnostic information. Contact CA Technical Support.

GSVX877I <taskid> task termination requested by main task

The IMS logger task was requested to terminate from the main task. This is a normal condition when the main task is terminating or when a termination command was entered for the logger task.

GSVX878I IMS subsystem <ssid> has terminated

The IMS subsytem indicated has terminated. Monitoring of this subsytem will be terminated.

GSVX879W < CSLOMI > warning - not all command clients responded, rc <return code> rs <reason code>

The IMSSPOC command was routed to multiple clients, however some may not have responded. See the IMS Common Service Layer Guide and Reference for a description of the return and reason codes returned by the CSLOMI service.

GSVX880I IMSLOGR dataspace <imsid> formatting completed

The IMSLOGR dataspace is initialized and formatted.

GSVX882I DCM BMP processing enabled for records: < record ids | ALL | NONE >

The IMSLOGR will monitor the event types specified in the message for non-message driven BMP region types. Record processing is controlled by the IMSLOGR PARMLIB option PROCESS-DCBMP-TYPE.

GSVX883I DCM DBT processing enabled for records: < record ids | ALL | NONE >

The IMSLOGR will monitor the event types specified in the message for CICS DBT region types. Record processing is controlled by the IMSLOGR PARMLIB option PROCESS-DCDBT-TYPE.

GSVX888I <p1> <p2>

IMS logger task trace and debugging message.

GSVX889I IMS Trace <text>

IMS logger task trace and debugging message.

GSVX900I <var1>

Informational only.

GSVX901I Command is not complete, still under development

Informational only.

GSVX902I <var>

Informational only.

GSVX903I <var>

Informational only.

GSVX904W <var>

Informational only.

GSVX905E <var>

Informational only.

GSVX906A <var>

Informational only.

GSVX907I <prodname> session started, <userid> <interface> <terminal>

This message is sent as a WTO when a SYSVIEW session has started and the OPTIONS PARMLIB SessionBeginEndWtoMessage option is set to YES. A period (C'.') will be displayed as a placeholder character for any message variable that is unknown.

GSVX908I <prodname> session ended, <userid> <interface> <terminal> <elapsedtime> <cputime> <cmdcount>

This message is sent as a WTO when a SYSVIEW session has ended and the OPTIONS PARMLIB SessionBeginEndWtoMessage option is set to YES. A period (C'.') will be displayed as a placeholder character for any message variable that is unknown.

GSVX909W RMF services not available

In order to get information for the requested display, RMF must be active. Start RMF and try the command again.

GSVX910E Not authorized to access RMF data

In order to get information for the requested display, the user must be authorized to access RMF data through the RMF programming interface (ERB3XDRS).

GSVX911E Unexpected situation occurred gathering RMF data

An unexpected situation occurred while getting the data for the requested display. Try the command again.

GSVX912W Data only available from <startdate> to <enddate>

A date range was entered that was not available. Enter a date in the range <startdate> to <enddate>.

GSVX913E Date/time range exceeds 9999 seconds

A date range was entered that exceeds the maximum allowed by RMF. Enter a valid date range.

GSVX914I CPC data not available

CPC data was not available for the requested system.

GSVX915I Insufficient storage to gather data

RMF could not obtain enough storage to gather all of the data. Increase the region size and try again.

GSVX916I Data not available for specified time

RMF could not obtain data for the specified time and date. Change the time and date and try again.

GSVX917W Data could not be obtained for at least one system

RMF could not obtain data for at least one of the systems listed. Check the Message field for the reason.

GSVX918E System name <system> not available

The specified system name could not be found in the available data. Reissue the command with a different system name.

GSVX919W Time gap from <startdate> to <enddate>

RMF could not retrieve the requested data due to a time gap. The message indicates the range of the missing data.

GSVX920I <ddname> LOGRExit <exitname> <exitaddr> Release <release> Build <build> <date> <time>

Informational message displaying information about the LOGR subsystem exit module.

GSVX921I <ddname> Open Log Stream <logstream>

Informational message indicating the OPEN event has been given control for the specified ddname and log stream.

GSVX922I <ddname> Options <options>

The options specified via the SUBSYS= parameter.

If a JCL error occurs during conversion, the <ddname> will contain "SUBSYS=".

GSVX923I <ddname> <recordtype> <count>

Statistics information about the records read from the log stream.

GSVX924W <ddname> BlkID <blkid> truncated. RecLen <reclen> BuffLen <bufflen>

A record passed back to the calling program has been truncated. Check the DCB attributed of the log stream specified.

GSVX925E <ddname> <macro> <request> RC <rc> RS <rs> Desc <desc>

An error has occurred during a call to the specified macro.

GSVX926I <ddname> BlkID <blkid> RecLen <before> : <after> <date> <time> <gmt|local>

The specific blkid or record has been read and passed back to the caller. The length of the record before and after record expansion is shown.

GSVX927I <ddname> <message> <date> <time> <gmt|local>

The available times read from the specified log stream.

message - 'Request start time '

'Oldest record found'

'Youngest record found'

GSVX928I <ddname> <message> <blkid>

The block IDs read from the specified log stream.

message - 'Oldest block ID read'

'Youngest block ID read'

GSVX929I Reserved

Reserved

GSVX930I Reserved

Reserved

GSVX931I Reserved

Reserved

GSVX932I Reserved

Reserved

GSVX933I Reserved

Reserved

GSVX934I Reserved

Reserved

GSVX935I Reserved

Reserved

GSVX936I Reserved

Reserved

GSVX937I Reserved

Reserved

GSVX938I Reserved

Reserved

GSVX939I Reserved

Reserved

GSVX940I 40I <ddname> Debug ASCB <ascb> ASID <asid> DSA <dsa> ECB <ecb> Parmlist <parmlist>

Internal debugging message. Contact CA Technical Support for more information if this message is displayed.

GSVX941I <ddname> <action> <label>

Internal debugging message. Contact CA Technical Support for more information if this message is displayed.

GSVX942I <prodname> <rel> <bld> <ssid> <copyright>

This is the SYSVIEW copyright message. The content of the message variables are:

GSVX943I Reserved

Reserved

GSVX944I Reserved

Reserved

GSVX945I Reserved

Reserved

GSVX946I Reserved

Reserved

GSVX947I Reserved

Reserved

GSVX948I Reserved

Reserved

GSVX949I Reserved

Reserved

GSVX950I SVCDUMP requested

Informational only.

GSVX951W SVCDUMP bypassed, <bypassreason>

Informational only.

GSVX952E SDUMPX failed, rc <rtncd> rsn <rsncd>

Informational only.

GSVX953E SDUMPX failed, <failurereason>

Informational only.

GSVX954I Issuing SDUMPX to capture SVC dump

Informational only.

GSVX955I Asid <asid> Job <jobnm>

Informational only.

GSVX956I Asid <asid> Job <jobnm> Dsp <dspnm>

Informational only.

GSVX957W SDUMPX complete, some data not captured

Informational only.

GSVX959I SDUMPX complete, SVC dump captured

Informational only.

GSVX960I SDUMPX retry <count> of <limit> in <secs> seconds

Informational only.

GSVX961E SDUMPX retry failed, <failreason>

Informational only.

GSVX962E SDUMPX failed, abend <abncmc>

Informational only.

GSVX963I Continuing with SYSUDUMP/ABEND/MDUMP processing

Informational only.

GSVX964E <func> not valid, <reason>

Informational only.

GSVX965I Recovery <descr> bypassed for <typ1 typ2>, @<32>

Informational only.

GSVX966I Retry environment from <source> key <key> state <state> am <amode> asc <ascmode>

Informational only.

GSVX967W Add FRR failed due to stack full, continuing without protection

Informational only.

GSVX968I Calling cleanup routines

Informational only.

GSVX969W IEALSQRY failed, rc <rc>

Informational only.

GSVX970I SDWARC1.SDWALSLV set to <lslv>

Informational only.

GSVX971I <type> CPU limit exceeded (<cpulim>)

Informational only.

GSVX972I Termination due to USS SIGKILL# signal (9)

The task is terminating because it received a UNIX System Services SIGKILL# signal (signal 9).

GSVX990I Reserved

Reserved

GSVX991I Reserved

Reserved

GSVX992I Reserved

Reserved

GSVX993I Reserved

Reserved

GSVX994I <status message text>

This message is used to display the contents of the STATSMSG parmlib member. The STATSMSG parmlib member contains message text that is displayed on the console prior to the output of the command:

MODIFY <id>,STATUS
GSVX995I <startup message text>

This message is used to display the contents of the STARTMSG parmlib member. The STARTMSG parmlib member contains message text that is displayed on the console during initialization of the SYSVIEW main, auxiliary, and user interface address spaces.

GSVX996I Pending message cleared

Informational only.

GSVX997I No pending message

Informational only.

GSVX998E <internal_message>

A request was made to issue an internal message externally to the console using the WTO macro. The internal message was embedded in this external message. Lookup the internal message identifier for additional information. The action character of this external message will be the same as the action character of the internal message identifier.

GSVX999E Unknown message - <msgid>

A request has been made to issue a message. The message ID is unknown or invalid. Note the <msgid> value and contact CA Technical Support.