The following available SET keywords let you control the display of the information lines:
Controls the display of the system overview information lines. Valid values are YES or ON and NO or OFF. For example:
set overview yes
If you turn the SET command parameter IMPLICITSET to yes, you can switch the OVERVIEW between yes and no.
set implicitset yes
Default: NO or OFF
Controls the format of the system overview information lines when the Overview option is set to Yes. Valid values are LONG or SHORT. FULL can also be specified and is a synonym for LONG.
Default: LONG
Controls the type of data displayed in the system overview information lines when the Overview option is set to Yes. Valid values are REALTIME or INTERVAL.
Default: REALTIME
OVERVIEWDivl or OVERDivline
Controls the display of a divider line following the system overview information lines when the Overview option is set to Yes. Valid values are Yes or On and No or Off.
Default: Yes
|