The parameter library data set member OPTIONS has been enhanced.
New Keywords
Specify the number of seconds from 1 to 600.
Default: 10
Specify the number of seconds from 1 to 600.
Default: 10
An abend occurs when a STORAGE OBTAIN or FREEMAIN request fails.
No abend occurs when a STORAGE OBTAIN or FREEMAIN request fails. A storage free failure message is logged.
Default: Yes
The TCB address of the caller of the STORAGE RELEASE or FREEMAIN request is checked against the TCB saved address when the storage was allocated. When the TCB addresses are not the same, the caller abends.
The TCB address is not checked.
Default: Yes
This value will:
When this limit is reached, an attempt to create a command environmental level is rejected.
Default: 64
Values can be YES or NO.
A value of NO means that the extended console names take the form:
GSVXnnnn
A number from 0000 to 9999.
A value of YES means that the extended console names take the form:
GSxxnnnn
The SYSCLONE value padded with 0 if the value is only one byte.
A number from 0000 to 9999.
YES must be specified when the PLEXCFG= value you specified in the IEASYSnn parmlib member is MONOPLEX. If YES is specified, then the SYSCLONE value must be unique for all systems within the GRS ring. A value of YES is acceptable for all other PLEXCFG= values as long as the SYSCLONE value is unique.
Specify a number of seconds from 1 to 600.
Default: 10
|