Enhancements to Existing Features › Options › Option for CICS › CICS Monitor Activation
CICS Monitor Activation
During the initialization of the CA SYSVIEW for CICS Data Collector, CICS monitoring classes are turned on or enabled.
The classes include:
- Monitoring - MN=YES
- Performance - MNPER=YES
- Exception - MNEXC=YES
- Conversational - MNCONV=YES
The following messages are written to the log to record the action and current state of CICS monitoring at initialization.
- GSVC051I (GSVI) CICS monitoring has been set ON. CICS setting OFF. CVDA value 200.
- GSVC051I (GSVI) CICS Performance monitoring has been set ON. CICS setting OFF. CVDA value 331.
- GSVC051I (GSVI) CICS Exception monitoring has been set ON. CICS setting OFF. CVDA value 333.
- GSVC051I (GSVI) CICS Conversational monitoring has been set ON. CICS setting OFF. CVDA value 601.
If CICS monitoring is activate and it was not originally desired or active, CA SYSVIEW ensures that unwanted records for performance and exceptions are not created. During the termination of the CA SYSVIEW for CICS Data Collector, CICS monitoring classes are restored to the original state.
The following messages are written to the log to record the action.
- GSVC051I (GSVI) CICS Conversational monitoring has been set OFF. CICS setting OFF. CVDA value 601.
- GSVC051I (GSVI) CICS Exception monitoring has been set OFF. CICS setting OFF. CVDA value 333.
- GSVC051I (GSVI) CICS Performance monitoring has been set OFF. CICS setting OFF. CVDA value 331.
- GSVC051I (GSVI) CICS monitoring has been set OFF. CICS setting OFF. CVDA value 200.
Copyright © 2012 CA.