Enhancements to Existing Features › Options › Option for IMS › Configuration Options - Parmlib member - IMSVARS
Configuration Options - Parmlib member - IMSVARS
The VARIABLE-SET option can be used to control the set of data collection metrics to collect. A new action has been defined to control the set of metrics that are sent to the Time Series Facility as part of the CA Chorus Infrastructure Management for Networks and Systems. Only those metrics that have been defined as TSF eligible can be enabled or disabled. The eligible list can be viewed on the IMSVARS command.
- VARIABLE-SET - source:variable:actions
- Variable - The data collection metric name. You can specify the name generically.
- The variable-length mask character: =
- The fixed-length mask character: *
- Actions - The actions to apply.
- ENAbled - Enable collection
- DISabled - Disable collection. TSF is also disabled.
- TSF - Enable TSF collection. The metric must also be enabled.