A qualifier establishes a conditional test resulting in a true or false condition. Qualifiers can be used with qualified rates, normalizers, and modifiers in the definition of conditional rates. The following panel set is used to define qualifiers.
The Qualifiers Entry panel is used to define the range of a qualifier.
You arrived at this panel by pressing F2 (Qualifier) on the Qualified Rates entry panel shown in Qualified Rates Entry Panel.
USERID CA PMA Chargeback MM/DD/YY HH:MM:SS __ Acctdefs Cbdefs Query Data Period Options Exit Help +-- CBCELMQ --------- Qualifier Entry -------------------+ | Panel Exit Help | | ------------------------------------------------------ | | Type information. Then select an action. | | | | Version . : PROD | | ORD Type . : MBJ | | Qualifier : @SHIFT1 | | | | ORD More: - + ____ Row 0001 of 0002 | | Cmd Field/@Qualifier Rop Field/Constant Lop | | | | _ START-TIME______ >= '0800'__________ and | | _ START-TIME______ < '1600'__________ ___ | | _ ________________ __ ________________ ___ | | _ ________________ __ ________________ ___ | | | | F2=Xref F5=Save F6=Delete F7=Bkwd F8=Fwd F11=Expand | +--------------------------------------------------------+ Command ===> ____________________________________________________________ F1=Help F3=Exit F4=Prompt F9=Command F10=Action Bar F12=Cancel PA1=Susp
Note: The first time this panel appears, you are in insert mode; no lines appear under the Cmd column, the scroll bar does not show a row count, and the only active panel function keys are F2, F5, and F11. When you press F5 (Save), a message appears telling you the insert is successful. At this point, you are in update mode. The panel scroll bar provides a row count, the Cmd column is active (lines appear under the column) and all panel function keys are active. Pressing F5 (Save) displays a message stating that the update was successful.
Next is a description of the Qualifier Entry panel.
The Qualifier Entry panel appears when one of these events occurs:
----------------
| Qualified |__________
| Rates | |
|>F2 | v
---------------- -----------------
| Qualifier |
| Entry |
| Panel |
-----------------
---------------- ▲
| Expanded |----------|
| Qualif. Entry|
|>F3 |
----------------
F7 and F8 let you scroll backward and forward through the Qualifiers definition list. You can also use the scroll bar to move through the entries.
The following Qualifier Entry panel fields are available for input:
This column is used to specify commands. Valid commands include:
D Deletes individual lines from the conditional test.
I Inserts lines into the conditional test using the Qualifier Insert (CBCQALI) pop-up window. Refer to page Sample Entry Panel Insert Pop-Up Window for information on how to use the insert window.
You use this column to identify the ORD Field or Qualifier name to be used. The contents of this Field Name is compared with the Field/Constant identifier provided in the Field/Constant column. Defines the qualifier named in the protected display field at the top of the panel.
Note: A qualifier can refer to other qualifiers. Nesting is permitted to any level.
Relational operator: acceptable entries include: < (less than), > (greater than), = (equal), or combinations, such as =< (equal to or less than) and &x'5f. = (not equal).
Defines the desired value, either another ORD Field or a specific result, that is used in the comparison with the ORD Field/@Qualifier.
(Logical operator) acceptable operators are: and and or.
Gives you a cross-referenced listing of all charge elements, other qualifiers, modifiers, and so forth that reference this qualifier.
Lets you add and update rows in the table.
Deletes the entire qualifier.
Lets you scroll backwards through the table.
Lets you scroll forward through the table.
Gives you an eight-line display of the Qualifier Entry panel.
| Copyright © 2012 CA. All rights reserved. |
|