The SSEXEXITHICOUNT parameter displays the highest number of process blocks from the main process block pool (see the PROCESS parameter) that were simultaneously in use since this CA OPS/MVS subsystem was last started or since this parameter value was last reset.
When you reset this value to zero, the SSEXEXITHIDATE and SSEXEXITHITIME display-only parameters are reset to zero.
Note: Resetting these values to zero affects the data recorded in the product SMF records and the reports produced by the AME.
No default value
The only possible value you can set this parameter to is zero.
Anytime
Example: SSEXEXITHICOUNT
This function resets the SSEXEXITHICOUNT value to zero.
OPSPRM('SET','SSEXEXITHICOUNT',0)
|