RULESxxBOUND Parameter

This parameter is the time boundary, in microseconds, for the xx counter that keeps track of system events for which an AOF rule executes. Such an event is counted through the RULESxxCOUNT parameter if its processing time falls above the previous RULESxxBOUND and just below the current RULESxxBOUND.

Default value

No default

Other possible values

Any number of microseconds

Set or modify this parameter...

Anytime

Example: RULESxxBOUND

This function sets the time boundary to 50 microseconds.