Previous Topic: CA 7-related ParametersNext Topic: CAIENF-related Parameters


INITCA7 Parameter

The INITCA7 parameter determines whether CA OPS/MVS detects CA 7 browse ENF events.

Default value

OFF|NO

This value prevents CA OPS/MVS from detecting CA 7 browse ENF events.

Other possible values

ON|YES

This value enables CA OPS/MVS to detect CA 7 browse ENF events.

Set or modify this parameter...

Anytime

Example: INITCA7

This function causes CA OPS/MVS to detect CA 7 browse ENF events:

OPSPRM('SET','INITCA7','YES')

Note: Changes take effect only the next time the CA OPS/MVS CAIENF interface task is recycled through the F OPSx,RESTART(CA7) command.

If the INITCA7 parameter is set to a value of ON and CAIENF is not available, the highlighted OPx0301S error message will be issued at regular intervals until CAIENF is started. If you want to avoid these error messages, we suggest that rather than unconditionally setting this parameter to a value of ON in the initial REXX exec, you provide automation to set this parameter appropriately and restart the CAIENF interface when CAIENF is available. Sample rules CAS9200I and CAS9300E are provided to do this.