CAIENFRATE Parameter

This parameter sets the rate by which CA OPS/MVS decrements the value of the CAIENFCURRENT counter every second.

Default value

50 (if the CAIENF interface is active)

Other possible values

Any number between 1 and 1,000

Set or modify this parameter...

Anytime

Example: CAIENFRATE

This function decrements the CAIENFCURRENT counter by 5 each second:

OPSPRM('SET','CAIENFRATE','5')