This parameter determines whether EOS events are evaluated by AOF EOS rules.
Note: The EOSRULES parameter is only valid when INITSMF is set to YES.
NO
End-of-step events trapped by the SMF IEFACTRT exit are not forwarded to AOF for rule evaluation.
YES
End-of-step events are evaluated by AOF EOS rules.
Anytime
Example: EOSRULES
This function activates AOF EOS rule processing.
OPSPRM('SET','EOSRULES','YES')
|
Copyright © 2014 CA.
All rights reserved.
|
|