Previous Topic: CICSROUTE ParameterNext Topic: CICSTIMERDEST Parameter


CICSTIMER Parameter

Determines whether CA OPS/MVS automates message OPS3420O, which reports the status of CICS operations. If you specify YES, CA OPS/MVS generates message OPS3420O every 15 minutes.

Default value

YES

Other possible values

NO

Set or modify this parameter...

Anytime

Example: CICSTIMER

This function prevents CA OPS/MVS from automatically issuing message OPS3420O:

OPSPRM('SET','CICSTIMER','NO')