This parameter dictates the maximum number of commands CA OPS/MVS can issue per second. When this number equals the value of the COMMANDCURRENT counter, CA OPS/MVS terminates and issues message OPS3146S. Setting the COMMANDMAX parameter to its maximum possible value prevents CA OPS/MVS from ever shutting down due to an excessive command rate.
200
Any number between 100 and 10000
Anytime
Example: COMMANDMAX
This function limits CA OPS/MVS to issuing 2000 commands.
OPSPRM('SET','COMMANDMAX','2000')
|
Copyright © 2014 CA.
All rights reserved.
|
|