You may use the following primary commands on the Automation Analyzer Results panel. Issue primary commands from the Command field.
Scrolls the panel so that the line referring to msgid is the top line on the panel. You can specify a partial ID. For example, issue this command to locate the first message ID that begins with the characters IST:
L IST
Sends a report to your ISPF LIST data set. With the exception of the information that appears in the Action Taken field, the report includes all of the information that the Automation Analyzer Results panel provides.
Sorts the list of messages according to the specified column. Values for columnname are: msg, msgid, and message (to sort by Message Identifier field); cnt, count, num, number, occ, and occurrence (to sort by # of Occr field); and sup, supp, and suppressed (to sort by OPS Supp.? field).
Specify up to three values for columnname. For example, issue this command to sort the messages first by CA OPS/MVS suppression and then by message ID:
SORT SUPP MSGID
Point-and-shoot is enabled to SORT the data on the Automation Analyzer Results panel using any valid column. To SORT the data on the Automation Analyzer Results panel using the point-and-shoot method, place the cursor on a valid column heading and press Enter.
Displays the Automation Analyzer summary statistics.
The following is a sample of the ISPF panel that appears when the STATS command is issued:
Automation Analyzer --- MSI1 --- O P S V I E W ---------------- Subsystem OPSS Command ===> Scroll ===> CSR Automation Analyzer Summary Statistics Total messages read from OPSLOG : 142161 Total messages analyzed : 60085 Total messages ignored : 82076 Messages suppressed by AOF rules : 0 ( 0.00% ) Messages suppressed by MPF : 967 MPF Suppressed messages ignored : 967 Non-SSI messages ignored : 4821 Secondary MLWTO messages ignored : 48254 Command Echoes ignored : 1831 Command Response messages ignored : 17200 Hardcopy only messages ignored : 9003 Table full messages ignored : 0 Number of message table entries : 15000 Press END to return to Automation Analyzer main panel.
|
Copyright © 2014 CA.