When you select option 7.4, the Run AMBLIST panel appears. CA OPS/MVS uses the information on this panel to create the IMSCMD1OFFSET and IMSAOI1OFFSET parameter statements and place them in a data set that you specify.
Following is a sample panel:
Run AMBLIST ---------- MSI1 ------ O P S V I E W ------------- Subsystem OPSS COMMAND ===> IMS LOAD LIBRARY DATA SET ===> 'IMSVS.RESLIB' (This library must contain DFSVNUCx) IMS NUCLEUS NAME ===> DFSVNUC0 AMBLIST PROGRAM LOCATION ===> 'SYS1.LINKLIB(AMBLIST)' (Specify the library and member name containing the AMBLIST program) OUTPUT PARAMETER DATA SET ===> 'SYS1.OPS.CCLXCNTL(IMSPARMS)' (Specify sequential dataset or PDS member to hold IMS parameters.) (This dataset should be merged into the product parmlib dataset.) Enter END command to return to UTILITY Options Menu
|