Previous Topic: Variable OutputNext Topic: Basic Element Variables


Global ARM Variables

The global ARM status variables reflect the overall state of ARM in the sysplex. The following variable names start with the prefix value as explained above:

ARMST_ARMSTATUS

Contains the functional status of ARM regarding its ability to perform restarts of failed elements. Values are ENABLED or DISABLED.

ARMST_ARMCONNECT

Contains the connection status of the ARM couple data set across the sysplex. Values are FULL or WARN when data may not be current due to one or more system failures.

ARMST_ARMELEMENTS

Contains the current count of element names in use by ARM.

ARMST_MAXELEMENTS

Contains the maximum number of element names allowed by the current ARM policy.