Previous Topic: OPAU Variables for OPSLOG Security EventsNext Topic: OPAU Variables for OPSPARM and OPSPRM Security Events


OPAU Variables for OPSOSF Security Events

The following variables are available for OPSOSF security events:

SEC.AUOSBULN

The command buffer length

Data Type: Integer, read-only

Source: The ADDRESS OSF host command

Sample Value: 5

SEC.AUOSCMBU

The complete ADDRESS OSF command buffer string

Data Type: Character, read-only

Source: The ADDRESS OSF host command

Sample Value: LISTA STATUS

SEC.AUOSHOEV

The name specified on the host command

Data Type: Character, read-only

Source: The host command environment name

Possible Values:

Sample Value: OSF

SEC.AUOSVBSR

The function type

Data Type: Character, read-only

Source: The ADDRESS OSF host command

Sample Value: LISTA