Using SSM Global Application › SSMGA Setup Requirements › Step 9: Replicate Parameters, RDF Tables, and Rules
Step 9: Replicate Parameters, RDF Tables, and Rules
Each eligible system (the primary system and all alternate systems) for each movable resource must have an identical resource table definition, an identical associated action table, and identical AOF rules (if not using shared AOF rule sets) for that movable resource. Required SSMGA parameters must be set on each system that will participate in the global SSMplex.
Note: Before executing this step, it is strongly recommended that you deactivate SSM processing on each system that will participate in the global SSMplex by setting the STATEMAN parameter as follows:
STATEMAN=INACTIVE
To replicate parameters, RDF tables, and rules
- On each eligible system, replicate resource tables containing movable resources by using the copy function of either the RDF Table Editor (OPSVIEW 2.6) or the SSM Resource Editor (OPSVIEW 4.11.R).
- On each eligible system, replicate action tables associated with resource tables containing movable resources by using the copy function of either the RDF Table Editor (OPSVIEW 2.6) or the SSM Action Editor (OPSVIEW 4.11.A).
- If not using shared AOF rule sets, on each eligible system, replicate and auto-enable any AOF rules (such as start, stop, state detection, and so on) for a movable resource.
- If not using a shared OPSPA00 initialization OPS/REXX program, update the OPSPA00 initialization OPS/REXX program with the required SSMGA parameters on each system that will participate in the global SSMplex.