Previous Topic: OPAU Variables for OPSCMD and ADDRESS OPER Security EventsNext Topic: OPAU Variables for OPSEPI Security Events


OPAU Variables for OPSCTL Security Events

The following variables are available for OPSCTL security events:

SEC.AUCTBULN

The command buffer length

Data Type: Integer, read-only

Source: The ADDRESS OPSCTL host command

Sample Value: 10

SEC.AUCTCMBU

The command buffer string

Data Type: Character, read-only

Source: The ADDRESS OPSCTL host command

Sample Value: MSF ACTIVATE(SYSA)

SEC.AUCTCMLN

The length of the current command verb

Data Type: Integer, read-only

Source: The ADDRESS OPSCTL host command

Sample Value: 2

SEC.AUCTCMSR

The current command verb

Data Type: Character, read-only

Source: The ADDRESS OPSCTL host command

Sample Value: OK

SEC.AUCTRQTY

The ADDRESS OPSCTL request type

Data Type: Character, read-only

Source: The ADDRESS OPSCTL host command

Possible Values:

SEC.AUCTSYNA

One of the following values:

The MSF system name to which the OPSCTL host command will be routed for execution

ALL if the command will be routed to all active MSF-defined systems including the local system

EXT if the command will be routed to all active, remote MSF-defined systems

Data Type: Character, read-only

Source: The ADDRESS OPSCTL host command

Sample Value: MSIX