Previous Topic: Monitoring

Next Topic: PGAIN and NEVAC EE Line Activation Failures


PALNK EE Line Activation Failures

A line status of PALNK indicates that VTAM's connection to the stack using the IUTSAMEH device is not active.

Use CA NetMaster NM for TCP/IP to check EE line activation

  1. From the command prompt, enter the following panel shortcut:
    /EEXCA
    

    The EE XCA Major Node Summary is displayed. The stack name appears in the top right of the page header. Line status is the second column.

  2. Note the stack name of any line with a status of PALNK.
  3. From the command prompt, enter the following panel shortcut:
    /STACK.M
    

    The IP Resource Monitor filtered for STACK is displayed.

  4. Verify that the stack is active for the system being checked.
  5. Enter DL against the required stack.

    The Device Links List is displayed.

  6. Verify that the IUTSAMEH device has status of READY (on IPv6 systems, scroll right).
  7. Verify that the source VIPA address is specified: