Ensure that all the associated started tasks and long-running jobs are active for the following:
Note: Ensure that the MUF is active and completely initialized before the Server job is submitted; otherwise, it fails.
You should see JOBLOG messages similar to the following for the MUF:
DB00201I - MULTI-USER ENABLED, CXX=AD11CXX MUFNAME=MUFLSTRT SVC=nnn AD DB00212I - SQL ENVIRONMENT ESTABLISHED DB00215I - CA Datacom/DB Database r11 at service pack: SP04
You should see JOBLOG messages similar to the following for the server:
DSV00049I-CA-Datacom Server 5.0 SP01 INITIALIZED -NETMASTEX
Ensure that the MUF and the server jobs remain active. A frequent situation is an undetected server job failure, usually with condition code 16. This occurs if you submit this job before the MUF job is completely initialized. Allow enough time between submitting each job.
If either of these jobs do not run or remain active, ensure that you have completed the CA Datacom/AD implementation steps correctly.
Incorrect implementation of the CA Datacom SVC can result in abends when the MUF job is started.
The MUF job must have an adequate region size. The default region size of CA Datacom/AD of 6144 KB is suitable when CA Datacom/AD is used only as a hierarchical database. ReportCenter uses the CA Datacom/AD relational database features, and the default region size is not adequate. You may need to increase it to approximately 50 MB.
| Copyright © 2012 CA. All rights reserved. |
|