REXX External Assembler API › Control Blocks › Parameter Block (PARMBLOCK)
Parameter Block (PARMBLOCK)
The parameter block and related control blocks are supported as follows:
- The PARMBLOCK_ID field is set to IRXPARMS.
- The PARMBLOCK_VERSION field is set to 0100. The PARMBLOCK_LANGUAGE field is set to ENU.
- The PARMBLOCK_MODNAMET field is set to the address of the module name table.
- The PARMBLOCK_SUBCOMTB field is set to the address of the subcommand table.
- The PARMBLOCK_PACKTB field is set to the address of the package table.
- The PARMBLOCK_FLAGS field has all flags set to zero, except that the flag and mask for the STORAGE function are set to indicate that the function is disabled.
- The PARMBLOCK_SUBPOOL field is set to 150 (an invalid subpool number).
- The PARMBLOCK_PARSETOK field is set to the PARSE token. The PARMBLOCK_ADDRSPN field is set to the address space name. The default value for both is NM.
Note: Unless otherwise noted, do not alter these areas.
|
Copyright © 2009 CA.