Previous Topic: Monitor Messages Using Consolidated Console

Next Topic: Consolidated Console Setup Requirements


Message Monitor

The message monitor is based on Operator Console Services (OCS).

Prefix Messages with the System Name

Use the following command to specify whether you want your messages prefixed with the originating system name:

PROFILE AOMPRFSN={NO | YES}

For example, to prefix the displayed messages with the system name, enter PROFILE AOMPRFSN=YES.

The changed value is valid for the current session only. If you want to specify a value to use whenever you access the message monitor as a consolidated console, specify the value at the Message Monitor Message Formatting panel of your user profile.