Previous Topic: Dx Messages

Next Topic: EEx Messages


EDx Messages

ED0001

Unable to retrieve user information

Reason:

The &SECCALL statement was used to check user authorization for the requested operation. This request was unsuccessful.

System Action:

The request is rejected.

User Action:

Determine the cause of the failure in the security system and retry.

ED0002

User not authorized to maintain panels

Reason:

You attempted to access Panel Maintenance, but you are not authorized.

System Action:

The request is rejected.

User Action:

Request authorization for panel maintenance from your installation and retry the request.

ED0003

Path P1 is not defined

Reason:

The path name entered on the Edit Services Primary Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

The path name is derived from your user definition. Contact you security system administrator.

ED0004

Library P1 is not defined

Reason:

The specified library name is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

Enter a valid library name.

ED0008

Library is not in path

Reason:

The library name entered is not part of your panel services path.

System Action:

The request is rejected.

User Action:

Enter a correct library name. Enter ? next to the Library Name field to display a list of valid library names.

ED0009

Edit not allowed on library P1

Reason:

You attempted to update the contents of a panel library ( P1 ), but the library is not authorized for editing.

System Action:

The request is rejected.

User Action:

Correct the library name and retry. Panel library specifications are controlled by the PANELLIBS Customizer parameter group.

ED0010

Invalid panel name

Reason:

You entered an invalid panel name.

System Action:

None.

User Action:

Correct the panel name and retry.

ED0011

Not authorized for supplied path

Reason:

You specified a path name that you are not authorized to access.

System Action:

The request is rejected.

User Action:

Enter your authorized path name and retry.

ED0012

Panel already exists

Reason:

The panel being added already exists in the library.

System Action:

The request is rejected.

User Action:

Use a different panel name.

ED0101

UNABLE TO RETRIEVE USER INFORMATION

Reason:

The &SECCALL statement was used to check user authorization for the requested operation. This request was unsuccessful.

System Action:

The request is rejected.

User Action:

Determine the cause of the failure in the security system and retry.

ED0102

User not authorized for Edit Services

Reason:

You attempted to access Edit Services facilities, but you are not authorized.

System Action:

The request is rejected.

User Action:

Contact your security administrator.

ED0103

PATH ~P1 IS NOT DEFINED

Reason:

The path name entered on the Edit Services Primary Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

Enter a correct path name and retry.

ED0105

SELECT AN OPTION OR PRESS A FUNCTION KEY TO PROCEED

Reason:

An option must be entered in the Select Option field, or a function key pressed in order to perform the desired action.

System Action:

None.

User Action:

Enter a valid selection on the menu.

ED0106

INVALID OPTION

Reason:

An invalid selection was entered in the Select Option field.

System Action:

None.

User Action:

Enter a valid selection on the panel.

ED0107

REQUIRED FIELD OMITTED

Reason:

A field which is required for the option selected was omitted.

System Action:

The cursor is placed in the field which must be entered and the field is highlighted.

User Action:

Enter a value for the required field.

ED0108

LIBRARY IS NOT IN PATH

Reason:

The library name entered on the Edit Services selection menu is not part of your panel services path.

System Action:

The request is rejected.

User Action:

Enter a correct library name. A selection list of valid library names is presented if a ? is entered next to the library field on the Edit Services Panel Move/Copy Menu.

ED0109

EDIT NOT ALLOWED ON LIBRARY

Reason:

You attempted to update the contents of a panel library, but the library may not be edited.

System Action:

The request is rejected.

User Action:

The EDITablity of a library is controlled by the LIBRARY and LIBPATH commands. Correct the library name, or alter its attributes to allow EDIT.

ED0110

PANEL NAME INVALID

Reason:

An invalid name was entered where a panel name was required.

System Action:

None.

User Action:

Correct the panel name and retry.

ED0111

NOT AUTHORIZED FOR SUPPLIED PATH

Reason:

A path name was supplied which you are not authorized to access.

System Action:

The request is rejected.

User Action:

Enter your authorized path name, and retry.

ED0112

EDIT SERVICES RESTRICTED FROM THIS SYSTEM

Reason:

You attempted to access Edit Services facilities, but they are not available on this system. Panel move and copy is therefore not available.

System Action:

The request is rejected.

User Action:

Edit Services is restricted by the SYSPARMS EDITMAXK=NONE command. Either make Edit Services available by resetting this operand, or work on another system.

ED0113

FIELD MUST BE YES OR NO

Reason:

The field containing the cursor must be either YES or NO.

System Action:

The cursor is placed in the field in error and the field is highlighted.

User Action:

Correct the field value and retry.

ED0114

'FROM' AND 'TO' LIBRARIES MUST NOT BE THE SAME

Reason:

Panels may be moved or copied from one library to another, but not into the same library.

System Action:

The cursor is placed in the field in error and the field is highlighted.

User Action:

Correct the library names and retry.

ED0115

ONLY ONE LIBRARY IN PATH - CANNOT COPY

Reason:

Panels may be moved and copied from one library to another, but not to the same library. There is only one library in the path, therefore the Panel Move/Copy utility is disabled for this path.

System Action:

The request is rejected.

User Action:

None.

ED1001

Tab to the required panel and enter S beside it to select it

Reason:

You have pressed F1 while in the Icon Panel selection list. To select an icon panel from the list, tab to the required panel and enter S beside it. The list is cursor-sensitive, so tabbing to the required panel and pressing Enter also selects that panel.

System Action:

None.

User Action:

None.

ED1002

Unable to open ICOPANL library, FILERC= P1

Reason:

An attempt to open the ICOPANL library to present a selection list of panels has failed with return code P.

System Action:

The list does not appear.

User Action:

Correct the file error and retry.

ED1101

LIBRARY NOT SELECTED FROM PANEL LIBRARY LIST

Reason:

A Panel Library List was presented and a library was not selected.

System Action:

None.

User Action:

None.

ED1201

PATH ~P1 IS NOT DEFINED

Reason:

The path name entered on the Edit Services Primary Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

Enter a correct path name and retry.

ED1301

LIBRARY IS NOT DEFINED

Reason:

The library name entered on the Edit Services Panel Move/Copy Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

Enter a correct library name. A selection list of valid library names is presented if a ? is entered next to the library field on the Edit Services Panel Move/Copy Menu.

ED1302

UNABLE TO OPEN LIBRARY - FILERC=~P1

Reason:

The library name entered on the Edit Services Move/Copy Menu cannot be opened. The return code from the FILE ID statement is shown.

System Action:

The request is rejected.

User Action:

Check that the library is open and accessible using the SH LIB and SH UDB commands.

ED1303

TOO MANY SORT FIELDS

Reason:

The SORT command on the Edit Services Panel Copy List has been issued. The command supports two sort fields but more than two were entered.

System Action:

None.

User Action:

Enter a valid SORT command and retry.

ED1304

INVALID SORT FIELD

Reason:

The SORT command on the Edit Services Panel Copy List has been issued. An unsupported sort field was entered.

System Action:

None.

User Action:

Enter a valid SORT command. The valid sort fields are NAME, CREATED, MODIFIED, SIZE, MLEV and ID, corresponding to the column headings on the selection list.

ED1305

~P1 RECORDS SORTED

Reason:

The SORT command on the Edit Services Panel Copy List has been issued and the displayed number of records was sorted.

System Action:

None.

User Action:

None.

ED1306

UNABLE TO RETRIEVE USER INFORMATION

Reason:

The &SECCALL statement was used to check user authorization for the requested operation. This request was unsuccessful.

System Action:

The request is rejected.

User Action:

Determine the cause of the failure in the security system and retry.

ED1307

USER NOT AUTHORIZED FOR EDIT SERVICES

Reason:

You attempted to access Edit Services facilities but you are not authorized.

System Action:

The request is rejected.

User Action:

Request authorization for Edit Services from your installation and retry the request.

ED1308

EDIT SERVICES RESTRICTED FROM THIS SYSTEM

Reason:

You attempted to access Edit Services facilities but they are not available on this system. Panel Move/Copy is therefore not available.

System Action:

The request is rejected.

User Action:

Edit Services is restricted by the SYSPARMS EDITMAXK=NONE command. Either make Edit Services available by resetting this operand, or work on another system.

ED1309

LIBRARY IS NOT IN PATH

Reason:

The library name entered on the Panel Services Primary Menu is not part of your panel services path.

System Action:

The request is rejected.

User Action:

Enter a valid library name. A selection list of valid library names is presented if a '?' is entered next to the library field on the Panel Services Primary Menu.

ED1310

EDIT NOT ALLOWED ON LIBRARY

Reason:

You attempted to update the contents of a panel library but the library may not be edited.

System Action:

The request is rejected.

User Action:

The EDITablity of a library is controlled by the LIBRARY and LIBPATH commands. Correct the library name, or alter its attributes to allow EDIT.

ED1311

NOT AUTHORIZED FOR SUPPLIED PATH

Reason:

An incorrect path name was supplied to the selection list. You are not authorized to access that path.

System Action:

The request is rejected.

User Action:

Enter the your authorized path name and retry.

ED2001

MEMBER IN USE BY ~P1

Reason:

The panel you wish to edit or delete is being edited or deleted by you (in another window) or another user. The userid is shown.

System Action:

The request is rejected.

User Action:

Wait until the panel is no longer in use, then retry the action.

ED2002

UNABLE TO ACCESS FILE - FILERC=~P1

Reason:

The panel library could not be opened. The return code from the FILE ID statement is shown.

System Action:

The request is rejected.

User Action:

Check that the library is open and accessible using the SHOW LIB and SHOW UDB commands, then retry.

ED2003

LIBRARY P1 IS NOT DEFINED

Reason:

The library name entered on the Edit Services Primary Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

Enter a correct library name. A selection list of valid library names is presented if a '?' is entered next to the library field on the Edit Services Primary Menu.

ED2004

PANEL ~P1 DOES NOT EXIST IN LIBRARY

Reason:

The library name entered on the Edit Services Primary Menu does not contain the specified panel.

System Action:

The request is rejected.

User Action:

Correct the library or panel name and retry.

ED2005

UNABLE TO OPEN '~P1' LIBRARY - FILERC=~P2

Reason:

The library name entered on the Edit Services Primary Menu cannot be opened. The return code from the FILE ID statement is shown.

System Action:

The requested selection list is not displayed.

User Action:

Check that the library is open and accessible using the SHOW LIB and SHOW UDB commands.

ED2006

PANEL ALREADY EXISTS IN 'TO' LIBRARY

Reason:

The panel being copied (with replace set to NO) already exists in the target library.

System Action:

The request is rejected.

User Action:

Correct the panel name or libraries, or use the REPLACE option to over-write the existing panel in the target library.

ED2007

~P1 PANELS ~P2 BEFORE ERROR ON THE 'TO' LIBRARY - VSAMFDBK=~P3

Reason:

Some panels were moved or copied to the 'TO' library before an error on the destination library occurred. The VSAMFDBK code explaining the error is shown.

System Action:

The move or copy operation is terminated.

User Action:

Check the reason for the error, correct and retry.

ED2008

PANEL ~P1 SUCCESSFULLY

Reason:

The panel has been moved or copied successfully.

System Action:

None.

User Action:

None.

ED2009

~P1 PANELS ~P2

Reason:

The number of panels displayed was moved or copied to the 'TO' library.

System Action:

None.

User Action:

None.

ED2010

~P1 PANELS ~P2, ~P3 NOT ~P2 BECAUSE REPLACE=NO

Reason:

The number of panels displayed was moved or copied to the 'TO' library. Some panel were not moved or copied, because the replace option was set to 'NO'.

System Action:

The panels which could be moved or copied without replacing an existing panel were moved or copied.

User Action:

If existing panels in the target library are to be replaced, then reissue the command with the replace option set to 'YES'.

ED2011

PANEL DEFINITION PRINTED

Reason:

The print command was used to print a panel definition. The print has been accepted by the print spooler (PSM).

System Action:

None.

User Action:

None.

ED2012

ERROR DURING PANEL ~P1 - VSAMFDBK=~P2

Reason:

Error occurred during panel rename or copy within library. The VSAMFDBK code explaining the error is shown.

System Action:

The rename or copy operation is terminated.

User Action:

Check the reason for the error, correct and retry.

ED9001

NO DATA TO BROWSE

Reason:

No data was found to be browsed.

System Action:

None.

User Action:

None.

ED9002

BLOCK COMMAND INCOMPLETE

Reason:

A block line command has been partially specified. That is, either the start line or end line has been specified but not both.

System Action:

The block command remains pending.

User Action:

Specify the start line and end line for the block command.

ED9003

MOVE/COPY PENDING

Reason:

A move or copy line command has been specified, but the position the lines are to be moved or copied to has not been specified.

System Action:

The move/copy command remains pending.

User Action:

Use the 'A' line command to indicate that the blocked data is to be moved or copied after that line, or use the 'B' line command to indicate that the blocked data is to be moved or copied before that line.

ED9004

'~P1' KEYWORD NOT SPECIFIED

Reason:

The mandatory keyword parameter identified by P1 was not specified when the editor was invoked.

System Action:

Processing is terminated.

User Action:

Correct and retry.

ED9005

'~P1' PARAMETER SPECIFIED WITH INVALID VALUE '~P2'

Reason:

The parameter identified by P1 was specified with an invalid value identified by P2 .

System Action:

Processing is terminated.

User Action:

Correct and retry.

ED9006

EDIT CANCELLED

Reason:

The user has cancelled the edit. No data has been modified.

System Action:

None.

User Action:

None.

ED9007

INVALID COMMAND

Reason:

An invalid command has been entered.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9008

'FLOW' NOT ALLOWED WITH OUTSTANDING LINE COMMAND

Reason:

The flow command cannot be entered when line commands are pending.

System Action:

The command is rejected.

User Action:

Complete or remove the line commands and retry.

ED9009

CURRENT MARGINS ARE: LEFT=~P1 RIGHT=~P2

Reason:

The margins are currently set to the displayed values.

System Action:

None.

User Action:

None.

ED9010

MARGINS SET: LEFT=~P1 RIGHT=~P2

Reason:

The margins have been set to the indicated column positions.

System Action:

None.

User Action:

None.

ED9011

INVALID VALUE FOR LEFT MARGIN - ~P1

Reason:

An invalid left margin value has been specified.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9012

INVALID VALUE FOR RIGHT MARGIN - ~P1

Reason:

An invalid right margin value has been specified.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9013

MARGINS MUST BE BETWEEN 1 AND ~P1

Reason:

An invalid right or left margin value has been specified.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9014

RECOVERY NOT SUPPORTED

Reason:

The recovery function is not supported by the application.

System Action:

The command is rejected.

User Action:

None.

ED9015

FIND STRING NOT SPECIFIED

Reason:

A character string was not specified on the find command.

System Action:

The command is rejected.

User Action:

Enter the character string to be found with the find command and retry.

ED9016

CHANGE STRING NOT SPECIFIED

Reason:

A character string was not specified for the change command.

System Action:

The command is rejected.

User Action:

Reenter the change command, specifying the character string to be changed and the new value of the character string.

ED9017

COPY NOT SUPPORTED

Reason:

The copy function is not supported in this application.

System Action:

The command is rejected.

User Action:

None.

ED9018

BEFORE OR AFTER MUST BE INDICATED

Reason:

A move or copy command has been entered but the position that the lines are to be copied or moved to has not been specified.

System Action:

The move or copy command remains pending.

User Action:

Specify where the lines are to be copied or moved by entering an 'A' or 'B' line command.

ED9019

COMMAND CONFLICT

Reason:

A number of mutually exclusive commands have been entered.

System Action:

The commands are not processed.

User Action:

Correct and retry.

ED9020

COPY SUCCESSFULLY COMPLETED

Reason:

A copy function has completed successfully.

System Action:

None.

User Action:

None.

ED9021

CREATE NOT SUPPORTED

Reason:

The create command is not supported in this application.

System Action:

The command is rejected.

User Action:

None.

ED9022

CREATE SUCCESSFULLY COMPLETED

Reason:

A create function has completed successfully.

System Action:

None.

User Action:

None.

ED9023

~P1 COMMAND NOT SUPPORTED IN ~P2 MODE

Reason:

A command has been entered that is invalid in the mode indicated.

System Action:

The command is rejected.

User Action:

None.

ED9024

SERVICE PROCEDURE ~P1 NOT FOUND

Reason:

The service NCL procedure was not found in the NCL procedure library.

System Action:

The function is terminated.

User Action:

Correct the service procedure name and retry.

ED9025

INVALID SCROLL AMOUNT

Reason:

An invalid scroll amount has been specified. Valid scroll amounts are (P)AGE, (H)ALF, (C)SR, (D)ATA, (M)AX or a number.

System Action:

None.

User Action:

Correct and retry.

ED9026

INVALID PARAMETER

Reason:

An invalid command parameter has been specified.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9027

CHARACTERS '~P1' CHANGED ~P2

Reason:

A change command has successfully completed.

System Action:

None.

User Action:

None.

ED9028

LINE TOO LONG TO APPLY CHANGE

Reason:

A line containing the character string to be changed would be longer than the maximum line length if the change was applied.

System Action:

The change is not applied.

User Action:

None.

ED9029

CHARACTERS '~P1' FOUND ~P2

Reason:

The character string specified on a find command has been found. If P2 is present it indicates that ALL was specified on the FIND command and the string was found the number of times indicated.

System Action:

The cursor is positioned at the beginning of the character string.

User Action:

None.

ED9030

*~P1 OF DATA REACHED*

Reason:

The end of the data, either in a forward (bottom) or backward (top), was reached before finding the specified character string.

System Action:

None.

User Action:

Press the Find key to continue the search from the top/bottom of the data.

ED9031

CHARACTERS '~P1' NOT FOUND

Reason:

The specified character string was not found in the data.

System Action:

None.

User Action:

None.

ED9032

COMMAND INVALID ON THIS LINE

Reason:

A line command was entered that is not valid on the line indicated.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9033

INVALID LINE COMMAND

Reason:

An invalid line command was specified.

System Action:

The command is rejected.

User Action:

Correct and retry.

ED9034

SCROLL MUST BE CSR, PAGE, HALF, DATA OR A NUMBER

Reason:

An invalid scroll amount was specified.

System Action:

None.

User Action:

Correct the scroll amount.

ED9035

FIELD MUST BE SPECIFIED

Reason:

The indicated field must be specified.

System Action:

None.

User Action:

Enter a valid value in the field.

ED9036

~P1 MUST BE A VALID ~P2

Reason:

An invalid value was entered in the field indicated.

System Action:

None.

User Action:

Enter a valid value in the field.

ED9037

RIGHT MARGIN MUST EXCEED LEFT MARGIN BY AT LEAST 20 CHARACTERS

Reason:

An attempt was made to set margins where the value of the right margin was less than the value of the left margin. The right margin value must be greater than the left margin and allow a minimum of 20 characters to be entered between the margins.

System Action:

The request is rejected.

User Action:

Change the values of the margins so that the value of the right margin is greater than the left margin and allows a minimum of 20 characters to be entered between them.

ED9038

CREATE ONLY VALID WHEN TEXT IS ENTERED

Reason:

User has attempted to issue a CREATE command without any text being present

System Action:

Request is rejected. CREATE fails.

User Action:

Enter text and retry.

ED9039

LINE CONTAINS CHARACTERS NOT SUPPORTED BY THIS DEVICE

Reason:

This message overlays a line of data if the line contains DBCS characters and the terminal is not DBCS capable.

System Action:

The line of data may be deleted, moved, copied but may not be editted.

User Action:

None.

ED9040

FUNCTION ONLY AVAILABLE IN 3270 ENVIRONMENT

Reason:

An edit screen can only be displayed in a fullscreen 3270 environment.

System Action:

The command is not processed.

User Action:

None.

ED9101

COMMAND CONFLICT

Reason:

A number of mutually exclusive commands have been entered.

System Action:

The commands are not processed.

User Action:

Correct and retry.

ED9102

UNABLE TO PROCESS COMMANDS. TEXT LINE LIMIT WILL BE EXCEEDED

Reason:

The editor has a physical restriction of 9999 text lines. The current set of commands will cause this limit to be exceeded.

System Action:

Restore the editor environment to the state prior to attempting to process this set of commands, and highlight all commands as being in error.

User Action:

Modify the line commands to a combination which will not cause the line limit to be exceeded. If the functions being performed are being done to facilitate further editing which will eventually lead to fewer than 9999 lines, it is possible to 'export' a subset of lines to the NOTEPAD where they may be freely edited and then 'imported' back to the editor.

ED9103

INCOMPLETE STRING SPECIFIED

Reason:

A change command was issued where either the "from" string or the "to"string were not completely specified. This error usually occurs when quotes are being used to delimit the string(s).

System Action:

Highlight the command in error.

User Action:

Re-enter the change strings taking care to ensure that quotes are balanced.

ED9104

REQUIRED STRING OMITTED

Reason:

A change command was issued where the "change to" string was not specified.

System Action:

Highlight the command in error.

User Action:

Enter the "change to" string and retry.

ED9105

~P1 NOT ALLOWED. ONE OR MORE TEXT LINES MUST BE SPECIFIED

Reason:

The P1 action is not allowed because no text lines were specified.

System Action:

Highlight the command in error.

User Action:

Specify one or more text lines and retry the command.

ED9106

LINE(S) NOT DELETED. NOT ALL DATA COULD BE MOVED

Reason:

This message is issued when a MOVE and OVERLAY command resulted in not all the text being moved. This could be caused by non-blank characters being positioned in the target line(s) in the same positions as non-blank characters in the source lines. It will also occur if more source lines are specified than target lines e.g. entering M6 on one line and O3 on another.

System Action:

Issue warning message, and don't delete source lines.

User Action:

Delete the source lines using D or DD, or specify a larger target area.

ED9107

MAXIMUM TEXT LINE LIMIT (~P1) EXCEEDED. TEXT CANNOT BE SAVED

Reason:

This message is issued when the application-supplied maximum text line limit (P1) has been exceeded. It is a warning message only, and normal processing will continue. However, you will not be permitted to exit from the editor, other than by cancelling, until the total number of lines is below the limit.

System Action:

Issue warning message, only allow exit via CANCEL.

User Action:

Reduce the number of text lines or CANCEL the edit session.

ED9108

TEXT LINE LIMIT EXCEEDED. ~P1 LINES LOST

Reason:

This message is issued when the physical maximum text line limit of 9999 has been exceeded as a result of Text Entry. The number of excess lines lost is contained in P1.

System Action:

Delete excess lines.

User Action:

None.

ED9109

AUTOMATIC RECOVERY IS ~P1

Reason:

This message is issued when the RECOVERY command is issued with no operands. It indicates the current state of RECOVERY processing.

System Action:

None

User Action:

None

ED9110

PRINT REQUEST ~P1 SENT TO PRINTER ~P2

Reason:

This is an informational message indicating that a print request has successfully been sent to the requested printer.

System Action:

None

User Action:

None

ED9111

'~P1' VALUE ~P2 INVALID WHEN '~P3' VALUE IS ~P4

Reason:

The value P2 that has been assigned to parameter P1 is invalid when parameter P3 has a value of P4.

System Action:

The procedure is terminated and an error message is returned.

User Action:

Correct the invalid parameter and retry the operation.

ED9112

AMBIGUOUS FIND STRING SPECIFIED

Reason:

A find command has been specified which the CAS Editor has been unable to satisfactorily parse. This message is issued when it is unclear what the string to be searched for is. An example of a FIND command which could cause this message to issue is "F FIRST LAST" in this case it is unclear whether the first occurrence of the word 'last' is being searched for, or the last occurrence of the word 'first'. Another example would be "F 'dog' cat" as it is again unclear what the actual text to be searched for is.

System Action:

The command is rejected and highlighted in error.

User Action:

Use single (') or double (") quotes to make the command unambiguous.

ED9113

LINE COMMAND DOES NOT SUPPORT DBCS DATA

Reason:

A line command has been entered on a line containing DBCS data. The command is not supported on this line.

System Action:

The command is rejected and highlighted in error.

User Action:

Correct and retry.

ED9114

CHARACTER NOT ELIGIBLE

Reason:

You have selected the 'HEX ATTR' option with the cursor positioned on a special character, for example, a DBCS shift character. This character is not eligible for display or alteration.

System Action:

None.

User Action:

Position the cursor elsewhere and retry.

ED9115

CURSOR MUST BE WITHIN TEXT

Reason:

You have selected the 'HEX ATTR' edit option, but the cursor is not positioned in the body of the text.

System Action:

None.

User Action:

Position the cursor in the body of the text and retry.

EDDB0001

Panel P1 saved in library P2

Reason:

Panel ( P1 ) was saved in library ( P2 ).

System Action:

None.

User Action:

None.

EDDB0002

Panel P1 does not exist in library P2

Reason:

The requested panel name ( P1 ) was not found in the specified library ( P2 ).

System Action:

The procedure is terminated.

User Action:

Correct the panel name or library name and retry.

EDDB0003

Cannot save panel P1, length P2 exceeds maximum of P3

Reason:

Panel P1 exceeds the maximum length for a panel record. The maximum length for a panel record is P3 .

System Action:

Request rejected.

User Action:

Reduce the size of the panel.

EDDB0004

Panel P1 deleted from library P2

Reason:

Panel ( P1 ) was deleted from library ( P2 ).

System Action:

None.

User Action:

None.

EDDB0005

Panel P1 renamed to P2 in library P3

Reason:

Panel ( P1 ) was renamed (to P2 ) in library ( P3 ).

System Action:

None.

User Action:

None.

EDDB0006

Panel P1 copied as P2 in library P3

Reason:

Panel ( P1 ) was copied (as P2 ) in library ( P3 ).

System Action:

None.

User Action:

None.

EDDB0007

Panel P1 P2 to library P3

Reason:

Panel ( P1 ) was copied or moved ( P2 ) to library ( P3 ).

System Action:

None.

User Action:

None.

EDDB0008

P1 panels P2 to library P3 P4

Reason:

A request to copy or move panels from one library to another was sucessful. In the message:
P1 is the number of panels copied or moved
P2 is the action performed (copied or moved)
P3 is the target library
P4 indicates the number of panels not replaced This message is suppressed if all panels are copied or moved because:
- The replace action is specified, or
- None of the selected panels exist in the target library.

System Action:

None.

User Action:

None.

EDDB0011

File ID P1 unavailable - FILERC P2

Reason:

The file from which you attempted to read a panel from is unavailable.

System Action:

Procedure terminated.

User Action:

See the NCL Reference for return codes from the &FILE OPEN verb.

EDDB0012

VSAM error on file get: Panel= P1, FileID P2, FileRC= P3 FDBK= P4

Reason:

An error occurred attempting to read a panel from a library. In the message:
P1 is the name of the panel
P2 is the library name (file ID)
P3 is the file return code (&FILERC)
P4 is the file feedback code (&VSAMFDBK)

System Action:

The procedure is terminated.

User Action:

See the &FILE GET verb description in the NCL Reference for return code and feedback values.

EDDB0013

VSAM error on file put: Panel= P1, FileID P2, FileRC= P3 FDBK= P4

Reason:

An error occurred attempting to write a panel to a library. In the message:
P1 is the name of the panel
P2 is the library name (file ID)
P3 is the file return code (&FILERC)
P4 is the file feedback code (&VSAMFDBK)

System Action:

The procedure is terminated.

User Action:

See the &FILE PUT verb description in the NCL Reference for return code and feedback values.

EDDB0014

VSAM error on file delete: Panel= P1, FileID P2, FileRC= P3 FDBK= P4

Reason:

An error occurred attempting to delete a panel from a library. In the message:
P1 is the name of the panel
P2 is the library name (file ID)
P3 is the file return code (&FILERC)
P4 is the file feedback code (&VSAMFDBK)

System Action:

The procedure is terminated.

User Action:

See the &FILE DEL verb description in the NCL Reference for return code and feedback values.

EDDB0021

Panel P1 already exists in P2 library

Reason:

You attempted to copy or move a panel ( P1 ) to another library ( P2 ) but the panel already exists in that library.

System Action:

Request rejected.

User Action:

If you want to replace the panel, use the replace action.

EDDB0101

Panel P1 successfully P2

Reason:

The panel identified by P1 performed the action by P2 successfully.

System Action:

None.

User Action:

None.

EDDB0102

Panel P1 not saved, no changes were made

Reason:

The panel identified by P1 was not saved because no changes were detected.

System Action:

None.

User Action:

None.

EDDB0103

Panel P1 already exists

Reason:

You attempted to create a new panel; however, the name specified already exists in that library.

System Action:

Request rejected.

User Action:

Specifiy a unique panel name and retry.

EDDB0104

Library P1 is not defined

Reason:

The library identified by P1 is not defined.

System Action:

Request rejected.

User Action:

None.

EDDB0105

Path P1 is not defined

Reason:

The path name entered on the Edit Services Primary Menu is not defined to the system.

System Action:

The requested selection list is not displayed.

User Action:

The path name is derived from your user definition. Contact your security system administrator.

EDDB0109

Edit not allowed on library P1

Reason:

You attempted to update the contents of a panel library ( P1 ), but the library is not authorized for editing.

System Action:

The request is rejected.

User Action:

Correct the library name and retry. Panel library specifications are controlled by the PANELLIBS Customizer parameter group.

EDDB0111

Invalid syntax - panel name must be specified

Reason:

You issued a command that requires a panel name to be specified; however, you omitted the panel name.

System Action:

Request rejected.

User Action:

Specifiy a panel name and retry.

EDDB0112

Invalid syntax - panel name P1 is invalid

Reason:

You entered an invalid panel name in the command.

System Action:

Request rejected.

User Action:

Specifiy a valid panel name and retry.

EDDB0113

Invalid syntax

Reason:

You issued a command with invalid syntax.

System Action:

Request rejected.

User Action:

See the online help. Correct syntax and retry.

EDDB0201

Panel P1 already exists

Reason:

The panel being renamed or copied already exists in the library.

System Action:

The request is rejected.

User Action:

Use a different new panel name or delete the existing panel name before doing rename or copy in the library.

EDDB0204

Invalid sort field

Reason:

You specified an invalid sort field name as part of the SORT command.

System Action:

None.

User Action:

Enter a valid SORT command. The valid sort fields are NAME, CREated MODified, SIZE, MLEV, and ID, corresponding to the column headings on the selection list.

EDDB0205

P1 records sorted

Reason:

The SORT command on the Edit Services Panel Selection List has been issued, and the displayed number of records was sorted.

System Action:

None.

User Action:

None.