The Global Online Parameters panel is displayed when option G2 on the PARAMETERS selection window is chosen.
APCDPP03 --- PMA Global Online Parameters ------------------------------------- COMMAND ===> Module Counts : 00000000 0 - 99999999 Module CPU-Consumption : 00.01 00.00-99.99 % CPU Time Cancel: CAN Save : END OR PF3
To reduce the effort for controlling and processing open alerts, you can define a consumption limit for threshold values that a module should consume. This function reflects your opinion regarding consumption information that is not important and allows the alert entries with consumption values below these thresholds to automatically be changed to state CTHR (Closed by THResholds). This feature allows you to concentrate your efforts on OPEN alerts.
The thresholds are valid for all types of online modules (that is, CICS and IMS). If the parameter is not defined in the parameter file, zero is used for each threshold as the default. If one of the consumption values is equal to or exceeds the corresponding threshold value (OR condition), the state of an existing pending alert is changed from PEND to OPEN. If no defined threshold is reached by any of the corresponding measurement consumption values, the state of an existing pending alert is changed from PEND to CTHR (closed by thresholds).
|
Field Name |
Description |
|
Module Counts |
Enter the threshold value of the module calls. |
|
Module CPU Consumption |
Enter the percentage of the module CPU consumption threshold. |
|
Copyright © 2012 CA Technologies.