The alert processing automatically identifies critical situations within a job step that require a measurement. Generally, alerts are created in two ways:
The alert management feature provides all the necessary information to handle the alert. A lot of information is provided in the form of state and reason codes that identify the situation. The following table provides a description of these codes.
|
State Code |
Reason Code |
Long Description |
|
PEND |
|
PMA provides a CA MAT measurement. A measurement is available if the alert state is changed to OPEN. |
|
ELPS |
|
|
|
ALTH |
This alert is created by job APCXJSMF by comparing SMF consumption values of a job to the defined alert thresholds. |
|
|
MODC |
This alert is created by job APCXJLIB as a result of a changed module. |
|
|
SRVR |
This alert is created by server. |
|
|
USER |
This alert is created by an online user. |
|
|
OPEN |
|
PMA has information about an alert, either a CA MAT measurement or user Text. |
|
ELPS |
The state was changed from PEND to OPEN by job APCYJLNA for one of the following reasons:
No further alerts are created except those of changed modules. |
|
|
TEXT |
This alert is created by an online user to indicate that no measurement was requested; however, user text information was provided. |
|
|
CHCK |
A user has initiated an alert for checkpoint writing. |
|
|
REV |
|
An online user selected an alert for review/inspection. |
|
all |
The state was changed by an online user by using command R(eview) in the Alert List Panel. No further alerts are provided by PMA. |
|
|
CUSE |
|
An online user closed the alert. |
|
all |
The state was changed by an online user by using command C(lose) in the Alert List Panel. |
|
|
CTHR |
|
PMA closed the alert automatically. No measurement is provided. |
|
ELPS |
The state was changed by job APCYJLNA because the measured job step abended or a CA MAT Scope change has affected a PEND alert. |
|
|
CIMP |
|
PMA closed the alert automatically. No measurement is provided. |
|
ELPS |
The state was changed by job APCYJLNA because the consumption values of the measurement did not exceed the statistical based alert values or a TOP Scope change affected a PEND alert. |
|
|
CMUL |
|
PMA closed the alert and temporarily stopped further alerts automatically. |
|
ELPS |
The state was changed by job APCYJLNA because more than three contiguous alerts with CTHR or CIMP were detected. No further measurements are provided until a module change is detected or an online user uses the D(elete) command in the Alert List Panel. |
|
|
COVT |
|
An online user closed the alert and took over the statistical data. |
|
ELPS |
The state was changed by an online user by using the overtake command O in the Alert List panel. In this case, the runaway values are the new statistical base for future tests. |
|