Alert Management

The alert processing automatically identifies critical situations within a job step that require a measurement. Generally, alerts are created in two ways:

The alert management feature provides all the necessary information to handle the alert. A lot of information is provided in the form of state and reason codes that identify the situation. The following table provides a description of these codes.

State Code

Reason Code

Long Description

PEND

 

PMA provides a CA MAT measurement. A measurement is available if the alert state is changed to OPEN.

ELPS
SRVU
SUIO
ELIO
CPIO

  • This alert is created by job APCXJSMF as a result of statistical calculations based on absolute values.
  • This alert is created by job APCXJSMF as a result of statistical calculations based on performance indexes.

ALTH

This alert is created by job APCXJSMF by comparing SMF consumption values of a job to the defined alert thresholds.

MODC

This alert is created by job APCXJLIB as a result of a changed module.

SRVR

This alert is created by server.

USER

This alert is created by an online user.

OPEN

 

PMA has information about an alert, either a CA MAT measurement or user Text.

ELPS
SRVU
MODC
USER

The state was changed from PEND to OPEN by job APCYJLNA for one of the following reasons:

  • A CA MAT measurement existed for a job step that was in the TOP Scope and had exceeded its statistical limits.
  • A measurement was stored in any case by user definition.

No further alerts are created except those of changed modules.

TEXT

This alert is created by an online user to indicate that no measurement was requested; however, user text information was provided.

CHCK

A user has initiated an alert for checkpoint writing.

REV

 

An online user selected an alert for review/inspection.

all

The state was changed by an online user by using command R(eview) in the Alert List Panel. No further alerts are provided by PMA.

CUSE

 

An online user closed the alert.

all

The state was changed by an online user by using command C(lose) in the Alert List Panel.

CTHR

 

PMA closed the alert automatically. No measurement is provided.

ELPS
SRVU
MODC
USER

The state was changed by job APCYJLNA because the measured job step abended or a CA MAT Scope change has affected a PEND alert.

CIMP

 

PMA closed the alert automatically. No measurement is provided.

ELPS
SRVU
MODC

The state was changed by job APCYJLNA because the consumption values of the measurement did not exceed the statistical based alert values or a TOP Scope change affected a PEND alert.

CMUL

 

PMA closed the alert and temporarily stopped further alerts automatically.

ELPS
SRVU
MODC

The state was changed by job APCYJLNA because more than three contiguous alerts with CTHR or CIMP were detected. No further measurements are provided until a module change is detected or an online user uses the D(elete) command in the Alert List Panel.

COVT

 

An online user closed the alert and took over the statistical data.

ELPS
SRVU

The state was changed by an online user by using the overtake command O in the Alert List panel. In this case, the runaway values are the new statistical base for future tests.