Previous Topic: CA MIA Activities During Local ShutdownNext Topic: Local System Shutdown With or Without ABEND Codes


Local Shutdown Procedure

This section describes a step-by-step local shutdown procedure. To avoid data integrity exposures, we recommend the following procedure to safely stop CA MIA on one local system in the complex:

Follow these steps:

  1. Quiesce tape activity on the local system.

    This process may include steps such as draining tape class initiators, quiescing online systems, and so on.

  2. Issue the following command on the local system:
    SHUTDOWN LOCAL
    
  3. Issue the following command for the local system on an external system:
    FREE sysname
    

    Note: The SHUTDOWN FREE command would replace Steps 2 and 3.

  4. Determine what tape devices are to be used by the local system when tape processing on that system is restarted.
  5. Issue the following command on an external system for each device that is identified in Step 4:
    VARY NOTAVAILABLE GLOBAL
    
  6. Wait for all VARY NOTAVAILABLE GLOBAL commands that are issued in Step 5 to complete.

    The completion includes waiting for any necessary deallocations to occur and each device to be taken offline on all systems.

  7. Issue the following z/OS command on the local system for each device that is identified in Step 4:
    VARY ONLINE 
    
  8. Restart tape processing on the local system.
  9. If any further devices are needed by the local system, repeat Steps 4 through 7 for each device.

Important! When issuing a z/OS VARY command for a device on the local system (Step 7) without previously issuing a VARY NOTAVAILABLE GLOBAL command for the device on an external system (Steps 5 and 6), it can create data integrity exposures. The same is true for replying with a device name to an IEF238D WTOR.