This procedure dynamically adds a system to an existing MIMplex when COMMUNICATION=CTCDASD or CTCONLY.
Note: Be sure that your COMPATLEVEL is set to 12.0 or higher.
Follow these steps:
In this example, we have a two system MIMplex with systems GK03 and GK13. We are going to add system GK62.
The current INIT member contains the following statements:
DEFSYS (GK03,03,XE03,INIT=FREED),
(GK13,13,XE13,INIT=FREED)
GLOBALVALUE VCFMASTER=(GK03,GK13),
MOSTP=YES,
NOMASTER=WAIT,
ANYELIG=YES
CTCPATH FROMSYS=GK03 TOSYS=GK13 ADDR=(183A,154A,B3A)
CTCPATH FROMSYS=GK13 TOSYS=GK03 ADDR=(183A,154A,B3A)
@D SYS
MIM0067I Command DISPLAY 355
MIM0108I SYSTEMS DISPLAY
INDEX ALIAS SYSTEM RELATION STATUS OPSYS LAST ACCESS
01 03 GK03 EXTERNAL MASTER zOS 2013.175 14:40:17.11
02 13 GK13 LOCAL ACTIVE zOS 2013.175 14:40:17.20
@D PATH
MIM0067I Command DISPLAY 359
MIM0176 MIM PATH DISPLAY:
LAST RESTART AT 14:39:35 ON 2013.175
DEV SYSTEM STATE IO-STAT READS WRITES ERR TIME/RSV CYCLES
N/A GK13 LOCAL 0 0 0
>183A GK03 IN-USE IDLE 305 305 0.001085 305
154A GK03 USABLE IDLE 0 0 0
0B3A GK03 USABLE IDLE 0 0 0
@D GLOBALV
MIM0067I Command DISPLAY 372
MIM0373I MIM GLOBALVALUE display:
ANYELIGIBLE=YES MOSTPREFERRED=YES NOMASTER=WAIT
VCFMASTER=( GK03, GK13 )
ELIGIBLE MASTER LIST: GK03, GK13
@D PATH MIM0067I Command DISPLAY 237 MIM0176 MIM PATH DISPLAY: LAST RESTART AT 14:39:23 ON 2013.175 DEV SYSTEM STATE IO-STAT READS WRITES ERR TIME/RSV CYCLES N/A GK03 LOCAL 0 0 0.000024 624 183A GK13 USABLE IDLE 621 621 0 154A GK13 USABLE IDLE 0 0 0 0B3A GK13 USABLE IDLE 0 0 0
@DEFSYS (GK62,62,XE62) MIM0067I Command DEFSYS 319 MIM0099I DEFSYS command is processing MIM0408I System Add Successful - GK62
@D SYS
MIM0067I Command DISPLAY 327
MIM0108I SYSTEMS DISPLAY
INDEX ALIAS SYSTEM RELATION STATUS OPSYS LAST ACCESS
01 03 GK03 LOCAL MASTER zOS 2013.175 14:44:03.55
02 13 GK13 EXTERNAL ACTIVE zOS 2013.175 14:44:03.55
03 62 GK62 EXTERNAL FREED <- new system
In this example, GK62 has the least amount of activity, so we want to put this system last in the list:
@GLOBALVALUE VCFMASTER(GK03,GK13,GK62) MIM0067I Command GLOBALVALUE 360 MIM0386W System GK62 is ineligible to become VCF MASTER MIM0193I GLOBALVALUE command processing initiated MIM0363I GLOBALVALUE command changes pending on external systems MIM0362I GLOBALVALUE command processing complete
@D GLOBALV MIM0067I Command DISPLAY 367 MIM0373I MIM GLOBALVALUE display: ANYELIGIBLE=YES MOSTPREFERRED=YES NOMASTER=WAIT VCFMASTER=( GK03, GK13, *GK62 ) ELIGIBLE MASTER LIST: GK03, GK13
GK62 becomes eligible when it is started.
Test the connectivity of the devices using the PROCCTC utility before you use the CTCPATH command.
@CTCPATH FROMSYS=GK03 TOSYS=GK62 ADDR=(184A,180A,B4A) MIM0067I Command CTCPATH 500 MIM0703I Path added for device 184A MIM0703I Path added for device 180A MIM0703I Path added for device 0B4A
Confirm the new paths:
@D PATH
MIM0067I Command DISPLAY 520
MIM0176 MIM PATH DISPLAY:
LAST RESTART AT 14:39:23 ON 2013.175
DEV SYSTEM STATE IO-STAT READS WRITES ERR TIME/RSV CYCLES
0B4A GK62 USABLE BUSY 0 0 0
WRITHDS
180A GK62 USABLE BUSY 0 0 0
WRITHDS
184A GK62 USABLE BUSY 0 0 0
WRITHDS
N/A GK03 LOCAL 0 0 0.000055 4,980
183A GK13 USABLE IDLE 4,969 4,969 0
154A GK13 USABLE IDLE 0 0 0
0B3A GK13 USABLE IDLE 0 0 0
@CTCPATH FROMSYS=GK13 TOSYS=GK62 ADDR=(187A,BFA,B7A) MIM0067I Command CTCPATH 685 MIM0703I Path added for device 187A MIM0703I Path added for device 0BFA MIM0703I Path added for device 0B7A
Confirm the new paths:
@D PATH
MIM0067I Command DISPLAY 695
MIM0176 MIM PATH DISPLAY:
LAST RESTART AT 14:39:35 ON 2013.175
DEV SYSTEM STATE IO-STAT READS WRITES ERR TIME/RSV CYCLES
0B7A GK62 USABLE BUSY 0 0 0
WRITHDS
0BFA GK62 USABLE BUSY 0 0 0
WRITHDS
187A GK62 USABLE BUSY 0 0 0
WRITHDS
N/A GK13 LOCAL 0 0 0
>183A GK03 IN-USE IDLE 4,859 4,859 0.001026 4,859
154A GK03 USABLE IDLE 0 0 0
0B3A GK03 USABLE IDLE 0 0 0
DEFSYS (GK03,03,XE03,INIT=FREED),
(GK13,13,XE13,INIT=FREED),
(GK62,62,XE62,INIT=FREED)
GLOBALVALUE VCFMASTER=(GK03,GK13,GK62),
MOSTP=YES,
NOMASTER=WAIT,
CTCPATH FROMSYS=GK03 TOSYS=GK13 ADDR=(183A,154A,B3A)
CTCPATH FROMSYS=GK03 TOSYS=GK62 ADDR=(184A,180A,B4A)
CTCPATH FROMSYS=GK13 TOSYS=GK03 ADDR=(183A,154A,B3A)
CTCPATH FROMSYS=GK13 TOSYS=GK62 ADDR=(187A,BFA,B7A) <-new
CTCPATH FROMSYS=GK62 TOSYS=GK03 ADDR=(184A,180A,B4A)
CTCPATH FROMSYS=GK62 TOSYS=GK13 ADDR=(187A,BFA,B7A) <-new
Note: If COMM=CTCDASD, ensure that the control files or list structures are allocated or cataloged on the new system.
S MIM,FORMAT=CHKPT
The new system joins the existing MIMplex.
Note: COMMUNICATION=CTCDASD does not require a checkpoint file. However, if you have one allocated due to using ECMF REQUEUE, then format it.
@DCSF
MIM0023I system GK62 in file VCF synchronization COMPLETE
MIM0067I Command DISPLAY 676
MIM0108I SYSTEMS DISPLAY
INDEX ALIAS SYSTEM RELATION STATUS OPSYS LAST ACCESS
01 03 GK03 EXTERNAL MASTER zOS 2013.175 14:53:19.61
02 13 GK13 EXTERNAL ACTIVE zOS 2013.175 14:53:19.66
03 62 GK62 LOCAL ACTIVE zOS 2013.175 14:53:19.67
GK62 is now ACTIVE.
MIM0373I MIM GLOBALVALUE display:
ANYELIGIBLE=YES MOSTPREFERRED=YES NOMASTER=WAIT
VCFMASTER=( GK03, GK13, GK62 )
ELIGIBLE MASTER LIST: GK03, GK13, GK62
GK62 is now an eligible master.
MIM0176 MIM PATH DISPLAY:
LAST RESTART AT 14:52:58 ON 2013.175
DEV SYSTEM STATE IO-STAT READS WRITES ERR TIME/RSV CYCLES
N/A GK62 LOCAL 0 0 0
187A GK13 USABLE IDLE 0 0 0
0BFA GK13 USABLE IDLE 0 0 0
0B7A GK13 USABLE IDLE 0 0 0
>184A GK03 IN-USE IDLE 3 3 0.001479 3
180A GK03 USABLE IDLE 0 0 0
0B4A GK03 USABLE IDLE 0 0 0
All 6 CTC addresses have been allocated and 184A is the path currently IN-USE to the VCFMASTER(GK03).
|
Copyright © 2014 CA.
All rights reserved.
|
|