3. REPORTS › 3.2 Standard Analysis Reports › 3.2.5 Equipment Reliability Summary Report
3.2.5 Equipment Reliability Summary Report
The Equipment Reliability Summary Report provides an
overview of the failure history of the equipment by class and
type of device. The failure history includes a usage count,
the number of permanent and temporary errors, and the ratio
of the usage count to the number of permanent and temporary
errors for the current period and a specified previous period
of time. See Section 3.1.5 for more information on this
report.
REPORT FORMAT:
See Section 3.1.5 for an example of the output generated by
the Equipment Reliability Summary Report.
DATA SOURCE (file/time-span):
SRLDRL, SRLMRL, SRLTRL, SRLXRL at the DETAIL or DAYS
time-span.
DATA ELEMENTS USED:
The data elements used for this report are:
___________________________________________________________
| | |
| FILE | DATA ELEMENTS |
|__________|_______________________________________________|
| | |
| SRLDRL | DRLPRMCT DRLTMPCT DRLLOGCT DRLSEKCT |
| SRLMRL | MRLPRMCT MRLTMPCT MRLSIOCT |
| SRLTRL | TRLPRMCT TRLTMPCT |
| SRLXRL | XRLPRMCT XRLTMPCT |
|__________|_______________________________________________|
REPORT DEFAULTS AND CONSIDERATIONS
The following table summarizes the keywords which may be used
for the Equipment Reliability Summary Report and gives their
default values.
A complete list of keywords and their descriptions can be
found in Section 3.2.9.
KEYWORD DEFAULT
---------------- --------------------------------
CURRENT aaa,bbb yesterday's date
PREVIOUS aaa,bbb 7 days prior to yesterday's date
TIMESPAN x,d DAYS
CYCLES nn DAYRANGE+1
DAYRANGE nn 7
SYSID list all SYSIDs
CPUSER list all CPUSERs
ERRORS nnn 1
CLASS ccc all CLASSes
TYPE ttt all TYPEs
EXCLUDE YES EXCLUDE NO
REPORT EQPSM -
Notes:
1. CURRENT may specify a single date or range of dates.
The default is to process data from yesterday only.
2. PREVIOUS may specify a single date or range of
dates. The default is to process data from the week
prior to yesterday.
3. Valid TIMESPAN values are DETAIL and DAYS. The
default is DAYS.
4. CYCLES may have any value. Note that the report
will attempt to select data from the date ranges
created by processing the CURRENT, PREVIOUS, and
DAYRANGE parameters.
5. DAYRANGE can have any value up to its maximum
allowed value. The default is 7 days.
6. The keywords SYSID and CPUSER may be used to limit
the data to be selected.
7. The keywords CLASS and TYPE may be used to limit the
report to specific equipment classes and types, such
as 3380.
8. If other keywords are used, they MAY AFFECT the
report. They are NOT ignored by the report.
The processing dates and ranges are calculated in the
following manner:
CURRENT period if the CURRENT keyword is not used, the
current period consists of the data from
yesterday's date.
if CURRENT enddate is specified, the
current period consists of the data from
the specified enddate.
if CURRENT startdate,enddate is specified
the current period consists of the data
in the range startdate to enddate.
PREVIOUS period IF the PREVIOUS keyword is not used, the
previous enddate is set to the date
before yesterday's date.
IF PREVIOUS enddate is specified, it is
used as the previous enddate.
Startdate is calculated by subtracting
the value for DAYRANGE. The previous
period is:
startdate-DAYRANGE+1 to enddate
If PREVIOUS startdate,enddate is
specified, it is used as the previous
period.
The current and previous periods must not overlap. If the
parameters cause an overlap to occur, data will be selected
for the current period first and then the previous period.
Copyright © 2014 CA.
All rights reserved.
 
|
|