Previous Topic: SNT00335Next Topic: SNT00337


SNT00336

+-----------------+
| S N T 0 0 3 3 6 |
+-----------------+

TEXT:        NETTCP SMF = NNN STATEMENT FOUND AFTER A DATA
             SOURCE STATEMENT THAT DID NOT SPECIFY NTCP
             OPTION OR THIS STATEMENT IS DEFINED MULTIPLE
             TIMES.

TYPE:        Error

REASON:      The NTCP option was not used in the DATA SOURCE
             statement that preceded the NETSPY SMF = nnn
             statement (which is used to declare the SMF
             record number for the NSPY data source). Another
             reason this message could be seen is that there
             may be a duplicate NETTCP SMF = nnn statement.

ACTION:      Edit prefix.MICS.PARMS(SNTOPS) and remove the
             statement in question, or specify the NTCP
             option on the preceding DATA SOURCE statement.

             Resubmit the prefix.MICS.CNTL(SNTPGEN).

REFERENCES:  Chapter 7 of this guide