4.6.1.2 Control Parameters


Figure 4-8 shows the Presentation Graphics screen that
contains the control parameters used in this case study.

---------------------------  Presentation Graphics  ---------------------------
|Command ===>                                                                 |
|Enter a ? in any data entry field for more information on valid values.      |
|Composing CA MICS Inquiry: CHNPLT - Channel 5 Workload Study                 |
|                                                                             |
|Report title ===> HISTORY OF CHANNEL 5 SIO COUNT                             |
|                                                                             |
|Selection criteria                                                           |
|              Input file ===> CHN - I/O Channel Example,03/10/93             |
|              Start date ===> _________ (ddmonyyyy)                          |
|                   SYSID ===> TSO1                                           |
|                    Zone ===> 1                                              |
|             No.  months ===>           (1-9999)                             |
|   Specify CAPAPU Values ===> N         (Y/N)                                |
|                                                                             |
|Data element             ===> CHAN5CNT                                       |
|Previous forecast date   ===> _________ (ddmonyyyy)                          |
|Y-Axis label             ===> SIO COUNT                                      |
|Plot type                ===> PRINTER   (COLOR/PRINTER)                      |
|Include Worksheets       ===> N         (Y/N)                                |
|                                                                             |
|Specify extended options ===> Y         (Y/N)                                |
|                                                                             |
-------------------------------------------------------------------------------

 Figure 4-8.  SIO Count Study Control Parameters

The parameters for the Presentation Graphics screen shown in
Figure 4-8 are defined below:

Report       The title that appears on the Presentation
title:       Graphics reports.

Input file:  The CHN resource element file that was
             originally defined in the extended example in
             Section 3.3.3.1 of this guide.

Start date:  The start date for date range selection.  Since
             neither start date nor number of months is
             specified for this analysis, no date range
             selection is applied to the historical
             observations from the CHN resource element file.

SYSID:       The historical observations for SYSID TSO1 only.

Zone:        The Zone, Hour, or Dayname to be included in the
             analysis.

No. months   The maximum number of months that will be
             included in the analysis.

Specify      The specification for CAPAPU.  The CHN resource
CAPAPU       element file was not defined as containing the
value:       CAPAPU data element, so no CAPAPU value may be
             specified on the CAPAPU Selection Values screen.

Data         The name of the data element (CHAN5CNT) in the
element:     capacity planning resource file which contains
             SIO counts for channel 5.

Previous     The date of any previous forecast.  In this
forecast     case, there are no previous forecasts, so the
date:        entry is left blank.

Y-Axis       The label for the Y-axis.  For this example, the
label:       label is SIO COUNT.

Plot type:   The specification for the type of plot.  PRINTER
             is selected for the line printer plot.

Include      The specification to include information
Worksheets:  produced through the use of the Capacity Planner
             Worksheet Facility.

Specify      Type a Y in this field to enter the extended
extended     options menu, shown in Figure 4-9.
options:

---------------------------  Extended Options Menu  ---------------------------
|Command ===>                                                                 |
|                                                                             |
|Inquiry Step:  Presentation Graphics                                         |
|                                                                             |
|Description text:                                                            |
| ===> LINEAR MODEL OF CHANNEL 5 SIO COUNT DEVELOPED WITH__________           |
| ===> GMA SMOOTHED DATA___________________________________________           |
| ===> ____________________________________________________________           |
| ===> ____________________________________________________________           |
| ===> ____________________________________________________________           |
| ===> ____________________________________________________________           |
|                                                                             |
|Override color graphics format parameters       ===> N (Y/N/R)               |
|                Color graphics format set       ===> PENPLOT                 |
|                                                                             |
|Specify Y-axis reference (capacity) lines       ===> N (Y/N/R)               |
|                                                                             |
-------------------------------------------------------------------------------

 Figure 4-9.  SIO Count Study Extended Options

The parameters for the Presentation Graphics Extended Options
Menu shown in Figure 4-9 are defined below:

Description  The descriptive text to appear as footnotes to
text:        the plot.

Override     Specify Y for yes, N for no, or R to reset and
color        return to previous value.
graphics
format
parameters:

Color        Enter the format type that you specified in
graphics     MICF.
format set:

Specify      Specify Y for yes, N for no, or R to reset and
Y-axis       return to previous value.
reference
(capacity)
lines: