2. SAMPLE PLANNING APPLICATIONS › 2.6 Coupling Facility Planning › 2.6.3 Standard Output
2.6.3 Standard Output
The capacity planning database file that is generated by the
Coupling Facility Planning Sample Application contains the
data following elements:
A. Data elements common to all CA MICS Capacity Planner
database files:
SYSID
ZONE or HOUR or DAYNAME
YEAR
MONTH or WEEK or MNTHDAY
DATE
B. Data elements unique to the Coupling Facility Planning
Sample Application database file:
1. Character format data elements
CAPAPU - SYSPLEX
CAPAPU2 - Coupling Facility Name
CAPAPU3 - System using Coupling Facility
2. Numeric format data elements
CFPTOCPU - Total Processors
CFPTOTSD - Total Storage Defined (KB)
CFPTOTSF - Total Storage Free (KB)
CFPTOCSD - Total Control Storage Defined (KB)
CFPTOCSF - Total Control Storage Free (KB)
CFPTODSA - Total Dump Storage Allocated (KB)
CFPTODSF - Total Dump Storage Free (KB)
CFPTOPTH - Total Paths Available
CFPTOREQ - Total Requests Made by this System
CFPTOURQ - Total Unsuccessful Requests
CFPTOSCG - Total Subchannels in IOGEN
CFPTOSCU - Total Subchannels in use
ALLTOREQ - Total Requests Made in SYSPLEX
ALLTOURQ - Total Unsuccessful Requests in SYSPLEX
3. Time format data elements
CFPTOBTM - Processor Busy Time
CFPTOWTM - Processor Wait Time
4. Percentage format data elements
PCTTOREQ - Percentage of total requests made by this
system
PCTTOURQ - Percentage of total unsuccessful requests
made by this system
Many of the data elements used in the Coupling Facility
Planning Sample Application database file have the same
meaning as their identically named counterparts in the
CA MICS database.
The data elements that are derived from the CA MICS database
and used by the Coupling Facility Planning Sample Application
are calculated as follows:
ALLTOREQ: The total number of requests made in the
Enhanced SYSPLEX.
ALLTOURQ: The total number of unsuccessful requests made
in the Enhanced SYSPLEX.
PCTTOREQ: The percentage of signals made by this system
in context of the entire Enhanced SYSPLEX.
PCTTOREQ = 100 * CFPTOREQ / ALLTOREQ
PCTTOURQ: The percentage of unsuccessful signals made by
this system in context of the entire Enhanced
SYSPLEX.
PCTTOURQ = 100 * CFPTOURQ / ALLTOURQ