2.4.6.4.1 DASD Multiple Volume Analysis Report Inquiry Panel

The DASD Multiple Volume Analysis Report is produced by
executing the DASD Multiple Volume Analysis Report Inquiry
panel (see Figure 2-124). This report normally analyzes and
recommends DASD volumes to be combined together on a higher
density device.  You can produce an alternative report that
monitors existing double density volumes (8650s) or proposed
groupings (2, 3, or 4-way) through specifying the MONITOR
option and specifying which volumes are to be grouped.

The following is a discussion of the fields on this panel.

Timespan:    The specification of whether the data is to be
             taken from the DETAIL or DAYS timespan.

Cycle(s):    One or more cycles from the CA MICS files
             that you want to use for analysis.  Because SMF
             data sets are not normally dumped at exactly
             midnight at most installations, a cycle from the
             CA MICS file usually contains a 24-hour period
             spanning two days.  Hence, some other type of
             selection may be required to generate a daily
             report.  This selection capability is provided
             by the DATE and HOUR control parameters.

Database:    The single-character CA MICS identifiers for the
             databases you want to access.

Allow        The indication of whether the database
Runtime      identifier and/or the Cycles specification can
Override:    be overridden at inquiry execution time.

Number of    The specification that determines whether groups
VOLs to be   containing two, three, or four devices must be
combined:    combined and reported.

Plot         The specification of whether the plot of the
contention   inter-volume contention index will be produced
index:       for each recommended grouping.

Volume       The following three fields combine to specify
Table        which volumes are to be analyzed or monitored.
Analysis
Method:

Analyze or   ANALYZE specifies that a recommendation report
Monitor:     is to be produced.  MONITOR specifies that the
             groupings you specified will be used in the
             analysis.

Analyze      Specifies that groups containing unlike device
unlike       types (such as a 3380 with a 3350) must be
VOLS:        allowed.  This is not recommended and will occur
             only if explicitly specified.

Specify      Specifies that a table of VOLSERs is to be
Volume       defined.
Table:

Least        The following two fields instruct the inquiry to
Active       analyze the specified number of volumes having
Volume       the least activity.
Analysis
Method:


Device       The device type (3350, 3380) of the DASD that is
type:        being combined to a higher density device.

NUM          The number of DASD volumes to be analyzed having
of VOLs:     the least activity.

Date:        The day(s) used for the analysis.  This field is
             normally used with the IOA Analysis inquiry to
             drop the extra day from a cycle due to the
             timing of the SMF dump.

Hour:        An hour or range of hours for which data is
             reported.

Zone:        The specification that zone selection is being
             applied.  If zone 1 definition is 8:00 a.m. to
             6:00 p.m., daily reports covering that time
             period can be specified by using the ZONE field
             set to 1.

Specify      The specification that allows you to supply
extended     additional report options.  These options
options:     include special SAS data selection statements,
             non-standard input, and output files.  These
             options are discussed in the sections that
             follow.

The operation of the time selection control parameters
depends on definitions made during the installation of
CA MICS.  If you are not sure about the zone definitions
for your installation or the CA MICS database update
procedures, consult your CA MICS System Administrator.


/-------------------  IOA DASD Multiple Volume Analysis Report  ------------------\
| Command ===>                                                                    |
|                                                                                 |
| Composing CA MICS Inquiry:  IOA43  - Analysis 100 Least Active Volumes          |
|                                                                                 |
| Time-span ===> DETAIL (DETAIL/DAYS)                      Cycle(s) ===> 01 - 02  |
| Data base ===> A (PRIMARY)  _            _            _            _            |
| Allow Run-Time Override of Data Base ===> N (Y/N) and/or Cycle(s) ===> N (Y/N)  |
|                                                                                 |
| Num of VOLs to be combined ===> 2 (2/3/4)   Plot contention index ===> N (Y/N)  |
|                                                                                 |
| Volume table method:                   :  Least active method: ** Specified **  |
|   Analyze or Monitor   ===> _ (A/M)    :    Device type ===> 3380  (3350/3380)  |
|   Analyze unlike VOLs  ===> _ (Y/N)    :    Num of VOLs ===> 100   (1-100)      |
|   Specify volume table ===> N (Y/N/R)  :                                        |
|                                                                                 |
| Data Selection:                                        Allow run-time override  |
|   Date         ===> _______ - _______   _______ - _______         ===> N (Y/N)  |
|   Hour         ===> __ - __    __ - __    __ - __                 ===> N (Y/N)  |
|   Zone         ===> _ _ _ _ _ _ _ _ _                             ===> N (Y/N)  |
|   Sysid        ===> ____ ____ ____ ____ ____ ____                 ===> N (Y/N)  |
|                                                                                 |
| Specify extended options ===> N (Y/N)                                           |
|                                                                                 |
\-------------------------------------------------------------------------------/


 Figure 2-124. IOA DASD Multiple Volume Analysis Report Inquiry Panel