Examine this report to see a list of all error messages associated with the JCL member that was submitted for CA JCLCheck processing. CA JCLCheck only produces this report if it detects one or more errors. You can direct this report to appear at the beginning or end of the report output or incorporate it into Report 2 - Listing of Merged JCL, depending on the setting of the ERROR option.
REPORT 6 - ERROR MESSAGES CA JCLCHECK SYS: xxxx JOB: PMK00100 PGMR: CAUSER FRIDAY SEPTEMBER 10, yyyy --------------------------------------------------------------------------------------------------------------------------------- STMT MESSAGE NUM NUMBER MESSAGE TEXT --------------------------------------------------------------------------------------------------------------------------------- 1. CAY6341E 'Class "O" is reserved for second shift usage, retry after 5 PM, it is only 4:50pm' 8. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 9. CAY6341W 'STEP3 is using 6 cartridge drives, please reduce utilization' 10. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 11. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 12. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 13. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 14. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 15. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 16. CAY6341E 'Step STEP4 has specified 11 DD names, this exceeds site standards' 17. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 18. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 19. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 20. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 21. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 22. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 23. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 24. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 25. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 26. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 27. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 29. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 30. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 31. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 32. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 33. CAY6341S 'JOB PMK00100 has encountered too many site violations. Execution has been aborted' CAY6000 26 STATEMENTS FLAGGED IN JOB 'PMK00100' MAXIMUM SEVERITY WAS 12
The following messages were flagged by REXX EXEC #1 during standards processing.
CAY6341E 'Class "O" is reserved for second shift usage, retry after 5 PM, it is only 4:50 pm.'
CAY6341W 'Step STEP3 is using 6 cartridge drives, please reduce utilization.'
CAY6341E 'Step STEP4 has specified 11 ddnames, this exceeds site standards.'
CAY6341S 'JOB PMK00100 has encountered too many site violations. Execution has been aborted.'
|
Copyright © 2013 CA.