Previous Topic: Examining Report 2 - Listing of Merged JCLNext Topic: JCLNeat REXX Programming Interface


Examining Report 6 - Error Messages

Examine this report to see a list of all error messages associated with this job. CA JCLCheck only produces this report if it detects one or more errors. You can direct this report to appear at the beginning or end of the report output or incorporate it with REPORT 2 - LISTING OF MERGED JCL, depending on the setting of the ERROR option.

REPORT 6 - ERROR MESSAGES CA JCLCHECK SYS: xxxx JOB: PMK00100 PGMR: CAUSER FRIDAY SEPTEMBER 10, yyyy ------------------------------------------------------------------------------------------------------------------------ STMT MESSAGE NUM NUMBER MESSAGE TEXT ------------------------------------------------------------------------------------------------------------------------ 1. CAY6341W 'Class "P" should be used for production jobs' 4. CAY6341E 'PERFORM parameter is not allowed, remove and rerun' 8. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 9. CAY6341E 'ADDRSPC=REAL is a restricted JCL parameter' CAY6341W 'Step STEP3 is using 6 cartridge drives, please reduce utilization' 10. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 11. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 12. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 13. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 14. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 15. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 16. CAY6341E 'Step STEP4 has specified 11 DD names, this exceeds site standards' 17. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 18. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 19. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 20. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 21. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 22. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 23. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 24. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 25. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 26. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 27. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION CAY6083E SPACE PARAMETER NOT PROVIDED FOR NEW DIRECT ACCESS DATASET 29. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 30. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 31. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 32. CAY6087W BLKSIZE NOT SPECIFIED FOR NEW OR DUMMY DATA SET - POTENTIAL S013 IN EXECUTION 33. CAY6341I 'PRODUCTION PROGRAMS CAN ONLY BE RUN BY THE AUTOMATED SCHEDULER' CAY6093E PROGRAM 'PSTEST9' NOT FOUND 34. CAY6341S 'JOB PMK00100 has encountered too many site violations execution has been aborted' CAY6000 27 STATEMENTS FLAGGED IN JOB 'PMK00100 MAXIMUM SEVERITY WAS 12

The following are the messages that were flagged by the REXX EXEC during standards processing.

STMT NUM 1.

CAY6341W 'Class "P" should be used for production jobs'

STMT NUM 4.

CAY6341E 'PERFORM parameter is not allowed, remove and rerun'

STMT NUM 9.

CAY6341E 'ADDRSPC=REAL is a restricted JCL parameter'

CAY6341W 'Step STEP3 is using 6 cartridge drives, please reduce utilization'

STMT NUM 16.

CAY6341E 'Step STEP4 has specified 11 DD names, this exceeds site standards'

STMT NUM 33.

CAY6341I 'PRODUCTION PROGRAMS CAN ONLY BE RUN BY THE AUTOMATED SCHEDULER'

STMT NUM 34.

CAY6341S 'JOB PMK00100 has encountered too many site violations execution has been aborted'