Previous Topic: Confirming the StandardNext Topic: Defining a Standards Rule


Selecting a Statement and Parameter/Subparameter Type

To define another rule for PRODSTD to check the program name and step name, CA JCLCheck uses what is known as procedure checking. CA JCLCheck checks the new statement and parameter types regardless of the results of previous tests (JOB NAME). So program name is checked regardless of whether an error was encountered in JOB NAME, because it is considered a new rule path.

  1. Scroll forward on panel CAZ1RTSP to view the statement and parameter type EXEC PGM.
  2. Enter S preceding EXEC PGM in the CMD field, and press Enter.

CAZ1RTSP ---- CA JCLCheck: RELATED STANDARDS (UPDATE) ------- ROW 31 OF 62 COMMAND ===> SCROLL ===> PAGE To select a Statement Type : Enter 'S' in CMD field, press Enter To return to previous panel: Press End CMD TYPE PARAMETER SUB-PARAMETER DD SYSOUT CLASS DD SYSOUT_2 WRITER DD SYSOUT_3 FORM DD UCS_1 CODE DD UNIT DD VOLUME_5 SERIAL_# EXEC ACCOUNT INFO EXEC ADDRSPC EXEC DPRTY_1 VALUE1 EXEC DPRTY_2 VALUE2 EXEC DYNAMNBR EXEC PERFORM S EXEC PGM EXEC PROCNAME EXEC REGION