Previous Topic: EXTDATA Record Type - SSTP

Next Topic: EXTDATA Record Type - SSST


EXTDATA Record Type - SUDP

The MRXT119D and MZXT119D record definitions define the EXTDATA created by CA JARS from SMF type 119 subtype 10 records, UDP Socket Close.

For a complete description of each SMF data field listed below, refer to the z/OS Communications Server IP Configuration Reference (SC31-8776). Appendix C, "SMF Type 119 Records," gives a detailed description of each field.

Additional information on the contents of SMF type 119 subtype 10 can be found by assembling the SMF mapping macro SYS1.MACLIB(EZASMF77), as in this example:

RECMAP   DSECT
         EZASMF77
         END

CA JARS EXTDATA Variable Name

IBM DSECT Name

IBM Variable Name

EXTSUDP_ID_SUBID

SMF119Header

SMF119HDSSI

EXTSUDP_ID_SYSNAME

SMF119Ident

SMF119TI_SYSName

EXTSUDP_ID_SYSPLEX

SMF119Ident

SMF119TI_SysplexName

EXTSUDP_ID_STACK

SMF119Ident

SMF119TI_Stack

EXTSUDP_ID_RELID

SMF119Ident

SMF119TI_ReleaseID

EXTSUDP_ID_COMP

SMF119Ident

SMF119TI_Comp

EXTSUDP_ID_ASNAME

SMF119Ident

SMF119TI_ASName

EXTSUDP_ID_SUSER

SMF119Ident

SMF119TI_UserID

EXTSUDP_ID_RESV1

SMF119Ident

Reserved

EXTSUDP_ID_ASID

SMF119Ident

SMF119TI_ASID

EXTSUDP_ID_REASON

SMF119Ident

SMF119TI_Reason

EXTSUDP_ID_RESV2

SMF119Ident

Reserved

EXTSUDP_USNAME

SMF119UD_UC

SMF119UD_UCRname

EXTSUDP_UCONNID

SMF119UD_UC

SMF119UD_UCConnID

EXTSUDP_USUBTASK

SMF119UD_UC

SMF119UD_UCSubTask

EXTSUDP_UOTIME

SMF119UD_UC

SMF119UD_UCOTime

EXTSUDP_UODATE

SMF119UD_UC

SMF119UD_UCODate

EXTSUDP_UCTIME

SMF119UD_UC

SMF119UD_UCCTime

EXTSUDP_UCDATE

SMF119UD_UC

SMF119UD_UCCDate

EXTSUDP_RIP

SMF119UD_UC

SMF119UD_UCRIP_IPV4

EXTSUDP_RIP1

SMF119UD_UC

SMF119UD_UCRIP_IPV4+0

EXTSUDP_RIP2

SMF119UD_UC

SMF119UD_UCRIP_IPV4+1

EXTSUDP_RIP3

SMF119UD_UC

SMF119UD_UCRIP_IPV4+2

EXTSUDP_RIP4

SMF119UD_UC

SMF119UD_UCRIP_IPV4+3

EXTSUDP_LIP

SMF119UD_UC

SMF119UD_UCLIP_IPV4

EXTSUDP_LIP1

SMF119UD_UC

SMF119UD_UCLIP_IPV4+0

EXTSUDP_LIP2

SMF119UD_UC

SMF119UD_UCLIP_IPV4+1

EXTSUDP_LIP3

SMF119UD_UC

SMF119UD_UCLIP_IPV4+2

EXTSUDP_LIP4

SMF119UD_UC

SMF119UD_UCLIP_IPV4+3

EXTSUDP_REMPORT

SMF119UD_UC

SMF119UD_UCRPort

EXTSUDP_LOCPORT

SMF119UD_UC

SMF119UD_UCLPort

EXTSUDP_UTYPE

SMF119UD_UC

SMF119UD_UCType

EXTSUDP_UREASON

SMF119UD_UC

SMF119UD_UCReason

EXTSUDP_UINDGRAMS

SMF119UD_UC

SMF119UD_UCinDgrams

EXTSUDP_UOUTDGRAMS

SMF119UD_UC

SMF119UD_UCOutDgrams

EXTSUDP_UBYTESIN

SMF119UD_UC

SMF119UD_UCInBytes

EXTSUDP_UBYTESOUT

SMF119UD_UC

SMF119UD_UCOutBytes

EXTSUDP_RIPV6

SMF119UD_UC

SMF119UD_UCRIP

EXTSUDP_RIPV61

SMF119UD_UC

SMF119UD_UCRIP+0

EXTSUDP_RIPV62

SMF119UD_UC

SMF119UD_UCRIP+2

EXTSUDP_RIPV63

SMF119UD_UC

SMF119UD_UCRIP+4

EXTSUDP_RIPV64

SMF119UD_UC

SMF119UD_UCRIP+6

EXTSUDP_RIPV65

SMF119UD_UC

SMF119UD_UCRIP+8

EXTSUDP_RIPV66

SMF119UD_UC

SMF119UD_UCRIP+10

EXTSUDP_RIPV67

SMF119UD_UC

SMF119UD_UCRIP+12

EXTSUDP_RIPV68

SMF119UD_UC

SMF119UD_UCRIP+14

EXTSUDP_LIPV6

SMF119UD_UC

SMF119UD_UCLIP

EXTSUDP_LIPV61

SMF119UD_UC

SMF119UD_UCLIP+0

EXTSUDP_LIPV62

SMF119UD_UC

SMF119UD_UCLIP+2

EXTSUDP_LIPV63

SMF119UD_UC

SMF119UD_UCLIP+4

EXTSUDP_LIPV64

SMF119UD_UC

SMF119UD_UCLIP+6

EXTSUDP_LIPV65

SMF119UD_UC

SMF119UD_UCLIP+8

EXTSUDP_LIPV66

SMF119UD_UC

SMF119UD_UCLIP+10

EXTSUDP_LIPV67

SMF119UD_UC

SMF119UD_UCLIP+12

EXTSUDP_LIPV68

SMF119UD_UC

SMF119UD_UCLIP+14