This report summarizes the storage use by each coupling facility. The amount of storage used for structures, dumping, and control are reported for each CF in the sysplex.
This report can be used to manage the amount of storage that is used for each purpose, and to make sure that the structures in the CF have sufficient memory for effective operation.
104/03/yy COUPLING FACILITY STORAGE SUMMARY PAGE 1 REPORT ID: ERXT0165 SYSPLEX: PLEXC1 SOURCE : SMF 74-4 PLEASE NOTE: ALL STORAGE VALUES ARE IN 4K PAGES -------------------------------------------------------------------------------------------------------------------------------- COUPLING STRUCT STRUCT DUMP SPC TOTAL CF CONTROL CONTROL NAME STG DEF STG USED ALLOC STORAGE STG DEF STG ALC % -------------------------------------------------------------------------------------------------------------------------------- 0 COUPLET1 507776 134049 1024 508800 508800 26.54 104/03/yy COUPLING FACILITY STORAGE SUMMARY PAGE 2 REPORT ID: ERXT0165 SYSPLEX: PLEXC1 SOURCE : SMF 74-4 PLEASE NOTE: ALL STORAGE VALUES ARE IN 4K PAGES -------------------------------------------------------------------------------------------------------------------------------- COUPLING STRUCT STRUCT DUMP SPC TOTAL CF CONTROL CONTROL NAME STG DEF STG USED ALLOC STORAGE STG DEF STG ALC % -------------------------------------------------------------------------------------------------------------------------------- 0 GRAND TOTAL 507776 134049 1024 508800 508800 26.54 1 REPORT RECORDS READ LINES PRINTED 1 85 26 -**** REPORT PHASE ENDED
|
Copyright © 2012 CA.