CNTL Function 14R: Remove Monitor On Screen

Remove any option directly from the Monitoring Status display, as discussed in the chapter "Menus and Displays." Specify individual locations to be removed exactly as you set them or by the ID number shown on the CA InterTest for CICS status display. To quickly remove all locations at once, enter .ALL in the first field as shown on the menu Œ and enter the same user ID (or .ANY) used to set the options.

The following screen is used to remove the monitor on locations that were previously set in the program for user ID CARAR01.

    CA InterTest MONITORING COMMAND BUILDER  SEGMENTED MONITORING LOCATIONS  14                                                                                      Remove `monitor on' option for  PROG=COBDEMO in any of the following fields:     (For qualification by nested program name, specify 'Programid:Label')       ŒParagraph .ALL___________________     _______________________________      Names:  _______________________________     _______________________________              _______________________________     _______________________________    Statement                                                           Numbers: __    _____    _____    _____    _____   _____    _____    _____                                                                                      Offsets: _____    _____    _____    _____    _____   _____    _____    _____                                                                                                            user ID (or .ANY) who will execute the program:             CARAR01

To remove by ID # shown in status display enter ID # s: -------------   

After specifying the locations, press Enter.