Previous Topic: Composite SupportNext Topic: Composite Support Screen


Customize Symbolic Information Using the Batch Method

Customizing symbolic information saves your monitoring configuration for future reuse and is optional. To customize symbolic information required for testing composite modules, submit a batch job to run IN25LINK.

Note: For more information about how to use the IN25LINK program, see the Symbolic Guide.

The CA InterTest for CICS batch job step, executed after the composite module is link‑edited, reads the link‑edit map to determine the link‑name, offset, and length of each subprogram. This step also specifies the names under which CA InterTest for CICS monitors each program.

Enable Composite Module Monitoring

To monitor each subprogram as if it were a separate load module, enable composite module monitoring.

Follow these steps:

  1. Access the Composite Support screen.
    1. In the Primary Option Menu, type 2.1.

      The Program Monitoring Menu opens.

    2. Enter the composite module name in the Program name field.
    3. Type S next to the Composite option, and press Enter.
  2. Select the subprograms that you want to monitor, and enter the monitor names for the subprograms that you selected.
    For more information, see Select Subprograms for Testing
  3. Press PF5 to confirm your selection.

Note: It is not necessary to enter information for the subprograms that you do not plan to test separately.