Set options to override the CA InterTest for CICS default protection rules for modifying main storage, the CSA, and load modules. Remove the protection options to reinstate the default protection rules.
Important! Because the protection options can potentially damage your CICS system if misused, exercise caution in specifying them. These options are password protected unless your site has removed this restriction.
To set or remove protection options follow these steps.
The Protection Options screen shown next opens. For detailed instructions, see The Function Selection Menu earlier in this chapter.
CA InterTest MONITORING COMMAND BUILDER PROTECTION OPTIONS 21 SET one or more options to override the default protection rules in: PROG=COBDEMO Bypass storage protection: From ________ To ________ Unprotect CSA: Offset ____ Length ___ Unprotect CWA: Offset ____ Length ___ Unprotect main storage area: Address ________ Length _____ Unprotect load module: Name ________ Protect main storage area: Address ________ Length _____ Limit monitoring to your TERMINAL '*' or TERMID: ____ user ID (or .ANY) who will execute the program _____
Specify the following options on this screen. In the descriptions, the command syntax equivalent for each monitoring option is specified in parentheses.
Bypass storage protection (BYP)—Permits a specified section of program code to modify any area of main storage, issue SVC instructions, or issue BALR, BASSM. or BASR 14,15 or 14,14 instructions.
Unprotect CSA (CSA)—Permits a program to modify areas in the CSA. Specify the offset and the length in hexadecimal.
Unprotect CWA (CWA)— Permits a program to modify areas in the CWA. Specify the offset and the length in hexadecimal.
Unprotect main storage area (LET)—Permits a program to modify a designated area of storage. Specify the beginning address as six to eight hexadecimal digits. Specify the length of the area in hexadecimal.
Unprotect load module (LET)—Permits a program to modify a load module.
Protect main storage area (PRO)—Prevents a program from modifying a designated area of storage not protected by CA InterTest. Specify the beginning address as six to eight hexadecimal digits. Specify the length of the area in hexadecimal.
Limit monitoring (TON)—Specifies that the program be monitored and that the protection options, if specified, take effect only when the program executes at the current terminal (*), a specific terminal (termid), or without a terminal (.NO).
|