During the packaging process, the product installation on the reference system of the Packaging Computer is recorded. After package creation has completed, the reference system is by default reset to its original state.
In the Tools, Options menu of the Packager main menu, you have the option to enable or disable resetting the reference system. By default, this option, called Enable Reset Reference System, is selected.
If the Enable Reset Reference System option is not selected (reset is disabled), all products that are installed on the reference system during package creation will remain there and are cumulated.
Disabling the reference system reset on the Packaging Computer can be of use when the Packager is installed on a virtual machine. In this case the reference system can be reset quickly by using a virtual snapshot.
Note: When reset is disabled, the Packager needs no backup files of the reference system. Consequently, all backup-related tasks and GUI items, for example, the Backup files tab in the Configure Reference System dialog, are removed from the Packager's user interface.
|