Following are some of the ways to resolve the errors reported by the scan:
cftrace -c set -f UAM -l DETAIL
Check the log files generated by the scanner for more details.
The AM manager can crash if the database or database listener is not active.
Symptom:
When I reload the same asset with a different MAC address, the Asset Collector creates duplicate entries for agents. The same behavior applies to the NRI assets.
Solution:
Duplicates entries are created because data is processed based on external_host_key and host_uuid. A new verification has been provided for the serial number to help ensure that duplicate entries are not created.
Do the following:
Run the following command to create the parameter and set the parameter value to 1:
ccnfcmda -cmd setparametervalue -ps /itrm/manager/engine -pn AssetMatchOnUniqueSerialNumber -v 1
This change allows a unique search for the serial number, in addition to the existing search for the hostuuid (hostname and MAC).
Symptom:
Create and and register OSIM images work successfully, but sdmpcworker logs event "File not found".
Solution:
You may ignore this log entry: The Microsoft loader tries to load fonts even when they are not required. The Microsoft loader then works without this font file, but the boot server logs the attempt to read the file with tftp.
Symptom:
When I collect the virtualization inventory for a Citrix XenServer platform using RVI Agent plug-in, the inventory attribute hostname under the node Virtualization, Citrix XenServer Virtual Machines shows incorrect values for some of the guest Virtual Machines.
Solution:
This problem happens if reverse IP lookup in the DNS table returns an incorrect hostname value or no value at all. To get the correct inventory data, ensure that IP and Hostnames are updated correctly in the DNS Server.
|
Copyright © 2013 CA.
All rights reserved.
|
|