Previous Topic: SYSGEN SYSTEM Statement for Interval RollNext Topic: DCMT VARY STATISTICS Command


DCMT DISPLAY STATISTICS Command

The DCMT DISPLAY STATISTICS command has been enhanced to enable reporting on the current statistics interval roll time.

DCMT DISPLAY STATISTICS Syntax

The following syntax shows updates to the DCMT DISPLAY STATISTICS command.

►►─ DCMT ─┬───────────────────┬─ Display STAtistics ─┬─ … ────┬────────►◄
          └─ broadcast-parms ─┘                      └─ ROLl ─┘

DCMT DISPLAY STATISTICS Parameters

This section describes the new parameters for the DCMT DISPLAY STATISTICS command:

ROLl

Displays the time date stamp of the last performed interval roll and the issuer of the request – either RHDCSROL system task, or the user by DCMT WRITE STATISTICS ROLL command, Displays the time of day in twenty-four hour format (HH:MM) and day interval at which statistics are written to the log and reset.

Example: Displaying the interval roll time

The following example shows that the statistics are written to the log and reset at 02:40 45 a.m. each seventh day.

DCMT D STATISTICS ROLL *** Display Statistics Interval Roll details *** Last Statistics Roll 2010-08-23-02.45.00.812033 Last Issued By SYSTEM TASK Interval Roll Time 02:45 Day Frequency 7