Previous Topic: z/VSE SystemsNext Topic: Overriding Startup Parameters from the Console


Operator Commands

Operator commands are available for use from the operator's console only.

The following table lists DC/UCF operator commands by function.

Note:

Purpose

Operator commands

Area management

  • DISPLAY AREA
  • VARY AREA

Buffer management

  • DISPLAY BUFFER
  • VARY BUFFER

Database management

DISPLAY DATA BASE

Journal management

  • DISPLAY JOURNAL
  • VARY JOURNAL

Log management

VARY LOG

Snap management

SNAP

System termination management

  • ABORT
  • SHUTDOWN

Operator command options

Operator command options are a subset of the equivalent DCMT commands as described in the following table:

Operator Commands

Supported Options

ABORT

DUMP

DISPLAY AREA

Area-name

DISPLAY BUFFER

Buffer-name

DISPLAY DATABASE

DISPLAY JOURNAL

SHUTDOWN

IMMEDIATE

SNAP

VARY AREA

Area-name, OFFLINE, ONLINE, PURGE, RETRIEVAL, TRANSIENT RETRIEVAL, and UPDATE

VARY BUFFER

Buffer-name, page-count

VARY JOURNAL

VARY LOG

Information displayed

The displays output for operator commands are similar to displays output for the equivalent DCMT commands. However, each line of output for an operator command always begins with the following information:

IDMS DCnnnnnn Vnn
DCnnnnnn

Specifies the message number.

Vnn

Specifies the system version number.

More Information