Previous Topic: DCMT VARY TCP/IP ParametersNext Topic: DCMT VARY TIME


DCMT VARY TCP/IP Usage

Specifying new socket values

New values can be assigned to max-sockets and max-socket-per-task when TCP/IP is currently enabled in the DC/UCF system, only if the new value is lower than the corresponding value at the time TCP/IP was enabled. In the other case, TCP/IP must be recycled. That is, disabled first and then reenabled.

The checks on the maximum number of sockets allowed are always done when a new socket is created. No sockets are forcibly closed if the maximum number of sockets is set to a lower value.