DCMT VARY AREA area-name OFFLINE
V AREA APPLDICT.DDLDML OFFLINE ---------- Area ----------- Lock Lo-Page Hi-Page #Ret #Upd #Tret #Ntfy APPLDICT.DDLDML Ofl 60001 62000 0 0 0 0 Stamp: 1999-05-05-09.48.14.948912 Pg grp: 0 NoShare NoICVI NoPerm
DCMT VARY AREA APPLDICT.DDLDML RETRIEVAL
V AREA APPLDICT.DDLDML RETRIEVAL ---------- Area ----------- Lock Lo-Page Hi-Page #Ret #Upd #Tret #Ntfy APPLDICT.DDLDML Ret 60001 62000 0 0 0 0 Stamp: 1999-05-05-09.48.14.948912 Pg grp: 0 NoShare NoICVI NoPerm
Use the DCMT VARY AUTOTUNE command to reset auto-tuning statistics and disable auto-tuning.
The following diagram shows the syntax for the new DCMT VARY AUTOTUNE command:
►►─ DCMT ─┬───────────────────┬───────────────────────────────────────►
└─ broadcast-parms ─┘
►── Vary AUTotune ─┬─ ALL ──────┬─┬─ RESET ─┬────────────────────────►◄
├─ DPE ──────┤ └─ OFF ───┘
├─ RCE ──────┤
├─ RLE ──────┤
└─ SYSlocks ─┘
This section describes the parameters for the DCMT VARY AUTOTUNE command:
Executes the DCMT command on all or a list of data sharing group members.
For more information about broadcasting and broadcast-parms syntax, see How to Broadcast System Tasks in the System Tasks and Operator Commands Guide.
Varies auto-tuning for all tuned parameters.
Varies auto-tuning of the DPE count parameter.
Varies auto-tuning of the RCE count parameter.
Varies auto-tuning of the RLE count parameter.
Varies auto-tuning of the SYSLOCKS parameter.
Resets historical information for the specified parameter so that tuning is based on future values only.
Disables automatic tuning for the specified parameters. Auto-tuning is disabled only for the current execution of the DC/UCF system.
Note: To permanently disable automatic tuning, you must change your system definition.
The following command resets statistics for auto-tuning SYSLOCKS:
DCMT V AUTO SYSLOCKS RESET SYSLOCKS has been reset
|
Copyright © 2014 CA.