DC643029

MORE THAN 1 KEY FOR VSAM CALC OR MODE IS VSAM INDEX

Reason:

A RECORD or SET statement for a native VSAM file specifies more than one control key element. Either a RECORD statement LOCATION MODE clause specifies VSAM CALC with multiple CALC element names, or a SET statement specifies ORDER IS SORTED, MODE IS VSAM INDEX and the MEMBER clause identifies multiple sort element names. Native VSAM usage accommodates only one control key. Modify the record or set description, specifying only one control key.

Module:

IDMSCHTR

Severity:

0