Previous Topic: DC598506Next Topic: DC598508


DC598507

PAGE <page-number> SR1 CALC POINTERS INCONSISTENT

Reason:

The next and prior pointers for the CALC set in the SR1 record on the indicated page are inconsistent; one points to the SR1 record and the other does not. If a set is empty, both next and prior pointers in the set owner should point to the owner; if a set is not empty, both next and prior pointers in the set owner should point to a set member.

Module:

IDMSDBN1

Severity:

0