Previous Topic: DC242027Next Topic: DC243002


DC243001

TASK: <task-code> PROG: <program-name>; USER EDIT ROUTINE CANNOT BE LOADED MAP <map-name> FIELD AT <row>, <column>

Reason:

The user-written edit module for the indicated map field could not be found in the load library. Verify that the edit module has been properly link edited by checking the link-edit listing. Display the directory of the DC/UCF load library (OS) or the core-image library (DOS), and verify the edit module name.

This message and DC243002 identify the same condition but are associated with different severities. The value specified for the EXECUTE ON ERRORS field of the CA ADS dialog compiler Response Process Definition screen determines which message a user receives. A NO value for the EXECUTE ON ERRORS field specifies that execution halts, the system abends the task, and the message DC243001 is issued when an edit module cannot be found for a field.

Module:

RHDCMAPR

Severity:

3